Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

被引:1
|
作者
Szczykutowicz, Timothy P. [1 ,2 ,3 ]
Labby, Zacariah E. [4 ]
Rubert, Nicholas [2 ]
Wallace, Charles [4 ]
机构
[1] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[4] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
关键词
quality assurance; quality control; computed tomography; cone beam CT; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; QUALITY-ASSURANCE;
D O I
10.1118/1.4940124
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:865 / 869
页数:5
相关论文
共 37 条
  • [31] Three-dimensional C-arm CT-guided transjugular intrahepatic portosystemic shunt placement: Feasibility, technical success and procedural time
    Ketelsen, Dominik
    Groezinger, Gerd
    Maurer, Michael
    Lauer, Ulrich M.
    Grosse, Ulrich
    Horger, Marius
    Nikolaou, Konstantin
    Syha, Roland
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4277 - 4283
  • [32] Technical Assessment of Dose and 3D Imaging Performance for a New Mobile Isocentric C-Arm for Intraoperative Cone-Beam CT
    Sheth, N.
    De Silva, T.
    Uneri, A.
    Ketcha, M.
    Han, R.
    Vijayan, R.
    Kleinszig, G.
    Vogt, S.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E111 - E111
  • [33] Architecture of a High-Performance Surgical Guidance System Based on C-Arm Cone-Beam CT: Software Platform for Technical Integration and Clinical Translation
    Uneri, Ali
    Schafer, Sebastian
    Mirota, Daniel
    Nithiananthan, Sajendra
    Otake, Yoshito
    Reaungamornrat, Sureerat
    Yoo, Jongheun
    Stayman, J. Webster
    Reh, Douglas
    Gallia, Gary L.
    Khanna, A. Jay
    Hager, Gregory
    Taylor, Russell H.
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [34] Ventriculoperitoneal shunt for brain displacement due to chronic subdural hematoma, using real-time navigated ventriculostomy by three-dimensional robotic C-arm: Technical note
    Lee, Jae Hwan
    Chang, Kai-Sheng
    Ou, Su-wei
    Cheng, Chun -Yuan
    Chen, Chien -Min
    Sun, Li - Wei
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2023, 31
  • [35] Accuracy and Safety of Freehand Placement of Upper Thoracic Pedicle Screws Supported Solely by Anteroposterior, i.e., Frontal, X-Ray Fluoroscopy (C-Arm): Technical Note Including 23 Patients
    Beucler, Nathan
    Cungi, Pierre-Julien
    Dagain, Arnaud
    Joubert, Christophe
    WORLD NEUROSURGERY, 2024, 191 : 25 - 34
  • [36] C-arm Cone-beam CT: General Principles and Technical Considerations for Use in Interventional Radiology (Reprinted from J Vasc Interv Radiol, vol 19, pg 814-820, 2008)
    Orth, Robert C.
    Wallace, Michael J.
    Kuo, Michael D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) : S538 - S544