Determination of lead(II) on a copper/mercury-plated screen-printed electrode

被引:27
|
作者
Zen, JM [1 ]
Chung, HH [1 ]
Kumar, AS [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem, Taichung 402, Taiwan
关键词
lead(II); screen-printed electrode; square-wave voltammetry;
D O I
10.1016/S0003-2670(00)01052-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Cu/Hg-plated screen-printed electrode (CMSPE) was developed for trace Pb(ll) determination by square-wave anodic stripping voltammetry. The intermetallic property of lead with copper in mercury was utilized to increase the sensitivity of Pb(II) detection. The calculated transfer coefficient value for the Pb(II)/Pb redox process on the CMSPE is similar to 0.5 representing the ideality of the system for Pb(II) detection. Systematic investigations were made to optimize the Cu-Hg plating condition on SPE towards the Pb(II) signals in terms of Cu/Hg ratio, plating potential, and plating time. The optimum conditions for electrochemical and square-wave parameters were also evaluated. The calibration curve was linear in the range of 0-100 ppb Pb(II) with a detection limit of 0.81 ppb (S/N = 3) for 60 s preconcentration time. The analytical utility of the CMPSE was demonstrated by applying to various water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 50 条
  • [31] Screen-Printed Voltammetric Biosensors for the Determination of Copper in Wine
    Norocel, Liliana
    Gutt, Gheorghe
    SENSORS, 2019, 19 (21)
  • [32] AMPEROMETRIC DETERMINATION OF COPPER USING SCREEN-PRINTED ELECTRODES
    SOMASUNDRUM, M
    BANNISTER, JV
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 15 (1-3) : 203 - 208
  • [33] Screen-Printed Carbon Electrode Modified with Carbon Nanotubes and Copper Film as a Simple Tool for Determination of Trace Concentrations of Lead Ions
    Grabarczyk, Malgorzata
    Wawruch, Agnieszka
    MEMBRANES, 2024, 14 (02)
  • [34] Electrochemical Determination of Lead & Copper Ions Using Thiolated Calix[4]arene-Modified Screen-Printed Carbon Electrode
    Mei, Chong Jin
    Yusof, Nor Azah
    Ahmad, Shahrul Ainliah Alang
    CHEMOSENSORS, 2021, 9 (07)
  • [35] Determination of the Real Surface Area of a Screen-Printed Electrode by Chronocoulometry
    Fragkou, Vasiliki
    Ge, Yi
    Steiner, Greg
    Freeman, Dom
    Bartetzko, Norbert
    Turner, Anthony P. F.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (07): : 6214 - 6220
  • [36] A new cysteamine-copper chemically modified screen-printed gold electrode for glyphosate determination
    Giancarla, Alberti
    Zanoni, Camilla
    Merli, Daniele
    Magnaghi, Lisa Rita
    Biesuz, Raffaela
    TALANTA, 2024, 269
  • [37] Immunosensor for the determination of okadaic acid based on screen-printed electrode
    Tang, A
    Kreuzer, M
    Lehane, M
    Pravda, M
    Guilbault, GG
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (7-8) : 663 - 670
  • [38] Nonenzymatic coated screen-printed electrode for electrochemical determination of acetylcholine
    Sayed Zia Mohammadi
    Hadi Beitollahi
    Somayeh Tajik
    Micro and Nano Systems Letters, 6 (1)
  • [39] Screen-printed ion-selective electrode for potassium determination
    Piorek, Izabella
    Peplowski, Andrzej
    Jakubowska, Malgorzata
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2019, 2019, 11176
  • [40] Simulating the phase II metabolism of raloxifene on a screen-printed electrode
    Vasiliadou, Rafaela
    Welham, Kevin J.
    CANADIAN JOURNAL OF CHEMISTRY, 2017, 95 (10) : 1085 - 1089