Surpass Evolve Flow Diverter for the Treatment of Intracranial Aneurysm: A Systematic Review

被引:14
|
作者
Issa, Rania [1 ]
Al-Homedi, Zahrah [1 ]
Syed, Dawood Hasan [1 ]
Aziz, Waseem [2 ,3 ]
Al-Omari, Basem [1 ,4 ,5 ]
机构
[1] Khalifa Univ, Coll Med & Hlth Sci, POB 27788, Abu Dhabi 127788, U Arab Emirates
[2] Sheikh Shakhbout Med City, Dept Neurosurg, P Box 11001, Abu Dhabi 11001, U Arab Emirates
[3] Alexandria Univ, Dept Neurosurg, Sch Med, Alexandria 21526, Egypt
[4] Khalifa Univ, Coll Med & Hlth Sci, Dept Epidemiol & Populat Hlth, POB 127788, Abu Dhabi 127788, U Arab Emirates
[5] Khalifa Univ Sci & Technol, KU Res & Data Intelligence Support Ctr RDISC, POB 127788, Abu Dhabi 127788, U Arab Emirates
关键词
surpass evolve; flow diverter; Stryker; intracranial aneurysm; systematic review; PIPELINE EMBOLIZATION DEVICE; ENDOVASCULAR TREATMENT; EXPERIENCE; COMPLICATIONS; TECHNOLOGY; DIVERSION; MORTALITY; STENT;
D O I
10.3390/brainsci12060810
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Purpose: This systematic review aims to summarize the evidence investigating the effectiveness and safety of the Surpass Evolve-Flow Diverter (SE-FD) to treat brain aneurysms. Method: We searched MEDLINE, EMBASE, CINAHL, Web of Science, and Cochrane Library from January 2019 to 29 March 2022. Terms related to the "intracranial aneurysm" and "surpass evolve flow diverter" concepts were used to search the databases; Medical Subject Headings (MeSH) and reference hand search were also utilized. Results: The searches primarily identified 1586 documents. A total of five studies (four case series and one cohort) were included in this review. In the included studies, 192 (74 male and 118 females) patients with 198 aneurysms were involved. In total, 153 SE-FDs were used to treat 145 aneurysms. Complete occlusion was achieved in 69/145 (48%) cases and near-complete occlusion in 24/145 (17%) cases from aneurysms treated with SE-FD. Reported postoperative complications included stent thrombosis (n = 4 patients), hemorrhage (n = 5 patients), ischemia (n = 9 patients), and neurological complications (n = 12 patients). In total, four deaths were reported with only one related to the SE-FD procedure. Conclusion: The results of this review are based on observational data, due to the absence of clinical trials. The findings of the included studies suggest that the effectiveness of the SE-FD procedure is lower than previous FDs but the safety is similar. The included studies also suggested that SE-FD has navigability and resistance to twisting, which makes the procedure an easier method to treat aneurysms that are proximal and distal to the circle of Willis deployment. This review highlights the urgency to conduct clinical trials to confirm these suggestions.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment
    Zhang, Y.
    Chong, W.
    Qian, Y.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (05) : 608 - 615
  • [22] First clinical experience with the new Surpass Evolve flow diverter: technical and clinical considerations
    Orru, Emanuele
    Rice, Henry
    De Villiers, Laetitia
    Klostranec, Jesse M.
    Wakhloo, Ajay K.
    Coon, Alexander L.
    Radovanovic, Ivan
    Kortman, Hans
    Bhatia, Kartik Dev
    Krings, Timo
    Pereira, Vitor M.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (10) : 974 - 980
  • [23] Surpass Flow Diverter in the Treatment of Ruptured Intracranial Aneurysms-A Single-Center Experience
    Mahajan, Anshu
    Das, Biplab
    Narang, Karanjit Singh
    Jha, Ajaya Nand
    Singh, Varindera Paul
    Sapra, Harsh
    Goel, Gaurav
    WORLD NEUROSURGERY, 2018, 120 : E1061 - E1070
  • [24] Surpass Flow Diverter for Treatment of Posterior Circulation Aneurysms
    Taschner, C. A.
    Vedantham, S.
    de Vries, J.
    Biondi, A.
    Boogaarts, J.
    Sakai, N.
    Lylyk, P.
    Szikora, I.
    Meckel, S.
    Urbach, H.
    Kan, P.
    Siekmann, R.
    Bernardy, J.
    Gounis, M. J.
    Wakhloo, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) : 582 - 589
  • [25] A systematic review and meta-analysis of the Derivo Embolization Device: a novel surface-modified flow diverter for intracranial aneurysm treatment
    Monteiro, Andre
    Burke, Samantha M.
    Baig, Ammad A.
    Khan, Slah
    Cappuzzo, Justin M.
    Waqas, Muhammad
    Dietrich, Joseph E.
    Levy, Elad, I
    Siddiqui, Adnan H.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2022, 14 (11) : 1125 - 1129
  • [26] Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review
    Lv, Xianli
    Yang, Hongchao
    Liu, Peng
    Li, Youxiang
    NEURORADIOLOGY JOURNAL, 2016, 29 (01): : 66 - 71
  • [27] Flow Diverter Performance Comparison of Different Wire Materials for Effective Intracranial Aneurysm Treatment
    Jun, Yeo Jin
    Hwang, Doo Kyung
    Lee, Hee Sun
    Kim, Byung Moon
    Park, Ki Dong
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [28] Intracranial Aneurysm Expansion Might Cause Neurological Deterioration After Flow Diverter Treatment
    de Korte, Antonius M.
    Aquarius, Rene
    Meijer, Frederick J. A.
    Boogaarts, Hieronymus D.
    de Vries, Joost
    WORLD NEUROSURGERY, 2018, 120 : E802 - E810
  • [29] Braid stability after flow diverter treatment of intracranial aneurysms: a systematic review and meta-analysis
    Ortega-Gutierrez, Santiago
    Rodriguez-Calienes, Aaron
    Vivanco-Suarez, Juan
    Cekirge, H. Saruhan
    Hanel, Ricardo A.
    Dibas, Mahmoud
    Lamin, Saleh
    Rice, Hal
    Saatci, Isil
    Fiorella, David
    Lylyk, Pedro
    Baltacioglu, Feyyaz
    Lylyk, Ivan
    Pereira, Vitor Mendes
    Gounis, Matthew J.
    Fiehler, Jens
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2023,
  • [30] A novel flow diverter device (Tubridge) for the treatment of intracranial aneurysms: a systematic review and meta-analysis
    Yingjun Fan
    Jun Lei
    Fan Fei
    Jun Liu
    Yanhui Liu
    Neurosurgical Review, 46