The systematic uncertainty of laboratory flow calibrations

被引:0
|
作者
Keyser, DR [1 ]
机构
[1] USN, Air Warfare Ctr, Div Aircraft, Patuxent River, MD 20670 USA
关键词
D O I
10.1115/1.2819647
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
There are two axioms applicable to this paper: the first is that no flowmeter can be more accurate than the laboratory which calibrated it; the second that no uncalibrated flowmeter can be more accurate than a like one that is calibrated in a recognized standards laboratory. The fundamental systematic uncertainty in flow measurement is that inherited from the flow calibration laboratory. This paper focuses on ascertaining this fundamental systematic uncertainty by deriving from the published instances of interlaboratory comparisons a value in which one may be 95 percent confident. For water flow measurements, this value turns out To be +/-0.28 percent, and for liquid hydrocarbon fuels it is +/-0.77 percent. Cold water calibrations are the most accurate.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 50 条
  • [41] UNCERTAINTY OF MEASUREMENT IN LABORATORY MEDICINE
    Milinkovic, Neda
    Ignjatovic, Svetlana
    Sumarac, Zorica
    Majkic-Singh, Nada
    JOURNAL OF MEDICAL BIOCHEMISTRY, 2018, 37 (03) : 279 - 288
  • [42] Inter-laboratory comparison of small water flow calibration facilities with extremely low uncertainty
    Furuichi, Noriyuki
    Terao, Yoshiya
    Ogawa, Shunichiro
    Cordova, Leopoldo
    Shimada, Takashi
    MEASUREMENT, 2016, 91 : 548 - 556
  • [43] A PROTOCOL FOR INTER-LABORATORY CALIBRATIONS OF BIOLOGICAL SPECIES IDENTIFICATIONS (RING TESTS)
    ELLIS, DV
    CROSS, SF
    WATER RESEARCH, 1981, 15 (09) : 1107 - 1108
  • [44] Enabling laboratory demonstrations of multi-object adaptive optics with linearity calibrations
    Ammons, S. Mark
    Laag, Edward A.
    Kupke, Renate
    Gavel, Donald T.
    Max, Claire E.
    ASTRONOMICAL ADAPTATIVE OPTICS SYSTEMS AND APPLICATIONS III, 2007, 6691
  • [45] INTERCOMPARISON OF DIFFERENT AETHALOMETERS WITH AN ABSORPTION TECHNIQUE - LABORATORY CALIBRATIONS AND FIELD-MEASUREMENTS
    RUOSS, K
    DLUGI, R
    WEIGL, C
    HANEL, G
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (17): : 3161 - 3168
  • [46] An estimate of uncertainty arising from loading speed differences in calibrations of force measuring devices
    Hayashi, Toshiyuki
    Katase, Yoshihisa
    Maejima, Hiroshi
    Yamaguchi, Yukio
    Ueda, Kazunaga
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 170 - +
  • [47] Phylogenetic uncertainty and molecular clock calibrations: A case study of legless lizards (Pygopodidae, Gekkota)
    Lee, M. S. Y.
    Oliver, P. M.
    Hutchinson, M. N.
    MOLECULAR PHYLOGENETICS AND EVOLUTION, 2009, 50 (03) : 661 - 666
  • [48] Uncertainty calculations in the quantitative analysis laboratory
    Cooper, Brian
    Carlin, Clifford
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [49] Multicandidate elections: Aggregate uncertainty in the laboratory
    Bouton, Laurent
    Castanheira, Micael
    Llorente-Saguer, Aniol
    GAMES AND ECONOMIC BEHAVIOR, 2017, 101 : 132 - 150
  • [50] Estimation of uncertainty in measurements in the clinical laboratory
    Kallner, Anders
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (12) : 2249 - 2251