Femoral cementing technique for hip resurfacing arthroplasty

被引:28
|
作者
Bitsch, Rudi G.
Heisel, Christian
Silva, Mauricio
Schmalzried, Thomas P.
机构
[1] Orthoped Hosp, Joint Replacement Inst, Los Angeles, CA 90007 USA
[2] Heidelberg Univ, Orthopad Klin, D-69118 Heidelberg, Germany
关键词
cementing technique; total hip; surface replacement;
D O I
10.1002/jor.20311
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The resurgence of metal-metal bearings has renewed interest in hip resurfacing, but a paucity of information exists regarding femoral cementing technique. We developed a laboratory model in which 72 open-cell foam specimens were used to simulate bone. Analyses of two cement viscosities, two foam porosities, and six cementing techniques were performed: manual cement application only, manual application and filling of one quarter of the component with cement, filling of half of the component, manual application and half component filling, full component filling, and manual application and full component filling. For manual application, cement was pressurized into the foam by rolling the finger tips. For component filling, a defined quantity of cement was poured into the component before pressing it onto the foam. Specimens were cut into quarters, and cement penetration was quantified in seven areas: top, chamfer, wall, interior area, and proximal, medial, and distal stem. The manual technique showed a 3-mm thick, even cement penetration of the outer fixation surface (top = 26 +/- 0 mm(2), chamfer = 14.9 +/- 10.2 mm(2), wall = 55.6 +/- 5.2 mm(2)). None of the other techniques showed a significantly higher penetration in these areas. Large differences were found between all techniques at the medial stem (27.7 +/- 17.5 mm(2), P < 0.001) and the interior area (128.5 +/- 69.6 mm(2), P = 0.013). An increasing degree of penetration occurred from manual cement application to manual application and full component filling. Sixteen specimens showed incomplete seating, which occurred with all techniques except the manual technique. The manual technique consistently gave an approximately 3-mm thick even cement penetration over the outer fixation area. Pouring any cement into the shell resulted in variable degrees of deeper penetration and a risk of incomplete seating, which have been associated with bone necrosis and early fracture. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:423 / 431
页数:9
相关论文
共 50 条
  • [31] Hip resurfacing arthroplasty
    Buergi, Martin L.
    Walter, William L.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 61 - 65
  • [32] Resurfacing hip arthroplasty
    Mont, MA
    Ragland, PS
    Marker, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) : 125 - 131
  • [33] Computational modelling of hip resurfacing arthroplasty investigating the effect of femoral version on hip biomechanics
    Bourget-Murray, Jonathan
    Taneja, Ashish
    Naserkhaki, Sadegh
    El-Rich, Marwan
    Adeeb, Samer
    Powell, James
    Johnston, Kelly
    PLOS ONE, 2021, 16 (05):
  • [34] Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip
    Olsen, M.
    Davis, E. T.
    Waddell, J. P.
    Schemitsch, E. H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (03): : 310 - 315
  • [35] Fracture of the femoral alignment stem of a hip resurfacing arthroplasty A case report
    Bhutta, Mohammed A.
    Shah, Vinod B.
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (01): : 128 - 131
  • [36] Notching of the femoral neck during resurfacing arthroplasty of the hip -: A vascular study
    Beaulé, PE
    Campbell, PA
    Hoke, R
    Dorey, F
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (01): : 35 - 39
  • [37] FEMORAL NECK BONE MINERAL DENSITY AFTER RESURFACING HIP ARTHROPLASTY
    Tapaninen, T.
    Kroger, H.
    Jurvelin, J.
    Venesmaa, P.
    SCANDINAVIAN JOURNAL OF SURGERY, 2012, 101 (03) : 211 - 215
  • [38] Early results of conversion of a failed femoral component in hip resurfacing arthroplasty
    Ball, Scott T.
    Le Duff, Michel J.
    Amstutz, Harlan C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04): : 735 - 741
  • [39] Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty
    Vogel, Danny
    Liebelt, Martin
    Kalkowsky, Florian
    Oberbach, Thomas
    Delfosse, Daniel
    Bader, Rainer
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (09) : 883 - 891
  • [40] Femoral Head Vascularity. Impact and Implications for Hip Resurfacing Arthroplasty
    White, Craig A.
    Beaule, Paul E.
    TECHNIQUES IN ORTHOPAEDICS, 2010, 25 (01) : 8 - 11