The interreader agreement and validation of contrast-enhanced ultrasound liver imaging reporting and data system

被引:31
|
作者
Li, JiaWu [1 ]
Ling, WenWu [1 ]
Chen, Shuang [1 ]
Ma, Lin [1 ]
Yang, Lulu [1 ]
Lu, Qiang [1 ]
Luo, Yan [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Ultrasound, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Contrast-enhanced ultrasound; Liver imaging reporting and data system; Liver; Hepatocellular carcinoma; HEPATOCELLULAR-CARCINOMA; LI-RADS; CANCER STATISTICS; RISK-FACTORS; DIAGNOSIS; GUIDELINES; CEUS; FEATURES; CRITERIA; UPDATE;
D O I
10.1016/j.ejrad.2019.108685
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study explored the interreader agreement and diagnostic performance of contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS). Methods: Between January 2014 and December 2017, 1366 patients at risk for hepatocellular carcinoma (HCC) who underwent CEUS were included in this retrospective study. Four ultrasound physicians rated the HCC likelihood of focal liver lesions (FLLs) using CEUS LI-RADS v2017. Interreader agreement on CEUS LI-RADS categories and major features (arterial phase hyperenhancement (APHE), washout appearance) were assessed using weighted kappa statistics (kappa). Diagnostic performance was described by sensitivity, specificity, PPV and NPV, +LR,-LR. Results: The interreader agreement (kappa) for CEUS LI-RADS categories, APHE, and washout appearance ranged from 0.61 to 0.73, 0.65 to 0.83, and 0.58 to 0.71, respectively. Interreader agreement for LI-RADS categories and APHE were almost substantial between FLLs < 2 cm, >= 2 cm,< 5 cm; interreader agreement for major features were fair to substantial for FLLs >= 5 cm. The accuracy, PPV and+ LR for HCC and malignancy in FLLs < 2 cm, >= 2 cm,< 5 cm, >= 5 cm were high, with values of 84.7% to 91.9%, 90.2% to 94.2%, and 2.2 to 8.0, respectively. CEUS LI-RADS had the highest specificity for HCC (90.2%) and malignancy (90.9%) diagnosis for FLLs < 2 cm and< 5 cm, respectively; specificity was lowest for HCC (54.7%) and malignancy (68.3%) diagnosis for FLLs >= 5 cm. Conclusions: CEUS LI-RADS is a good standardized categorization system for high-risk patients, and the combination of two or three LR-M features may improve the true-negative classification of HCC diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Contrast-enhanced ultrasound applications in liver transplant imaging
    Giuseppe Como
    Luca Montaldo
    Umberto Baccarani
    Dario Lorenzin
    Chiara Zuiani
    Rossano Girometti
    Abdominal Radiology, 2021, 46 : 84 - 95
  • [32] Contrast-enhanced Ultrasound for Liver Imaging: Recent Advances
    Salvatore, Veronica
    Borghi, Alberto
    Piscaglia, Fabio
    CURRENT PHARMACEUTICAL DESIGN, 2012, 18 (15) : 2236 - 2252
  • [33] Tumor size-based validation of contrast-enhanced ultrasound liver imaging reporting and data system (CEUS LI-RADS) 2017 for hepatocellular carcinoma characterizing
    Pan, Jia-Min
    Chen, Wei
    Zheng, Yan-Ling
    Cheng, Mei-Qing
    Zeng, Dan
    Huang, Hui
    Huang, Yang
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    Hu, Hang-Tong
    Chen, Li-Da
    Wang, Wei
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1126):
  • [34] Contrast-enhanced ultrasound applications in liver transplant imaging
    Como, Giuseppe
    Montaldo, Luca
    Baccarani, Umberto
    Lorenzin, Dario
    Zuiani, Chiara
    Girometti, Rossano
    ABDOMINAL RADIOLOGY, 2021, 46 (01) : 84 - 95
  • [35] Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions
    Luo, Jun
    Chen, Ji-Dong
    Chen, Qing
    Yue, Lin-Xian
    Zhou, Guo
    Lan, Cheng
    Li, Yi
    Wu, Chi-Hua
    Lu, Jing-Qiao
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (06): : 610 - 617
  • [36] INTERREADER AGREEMENT IN MULTIPARAMETRIC MRI REPORTING USING PROSTATE IMAGING REPORTING AND DATA SYSTEM VERSION 2.1
    Brembilla, Giorgio
    Dell'Oglio, Paolo
    Stabile, Armando
    Damascelli, Anna
    Cristel, Giulia
    Ravelli, Silvia
    Esposito, Antoinio
    Briganti, Alberto
    Montorsi, Francesco
    De Cobelli, Francesco
    JOURNAL OF UROLOGY, 2020, 203 : E849 - E849
  • [37] Diagnostic efficacy of the contrast-enhanced ultrasound thyroid imaging reporting and data system classification for benign and malignant thyroid nodules
    Yang, Yu-Ping
    Zhang, Guo-Li
    Zhou, Hong-Lian
    Dai, Hai-Xia
    Huang, Xing
    Liu, Li-Juan
    Xie, Jun
    Wang, Jie-Xin
    Li, Hua-Juan
    Liang, Xin
    Yuan, Qian
    Zeng, Yan-Hao
    Xu, Xiao-Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (08) : 5721 - 5736
  • [38] Advantages of the Korean Thyroid Imaging Reporting and Data System Combined with Contrast-Enhanced Ultrasound in Diagnosing Papillary Thyroid Microcarcinoma
    Zhao Huaqun
    Liu Xueling
    Lei Bei
    Cheng Ping
    Li Jian
    Wu Yedong
    Ma Zhen
    Wei Fang
    Su Hongyue
    IRANIAN JOURNAL OF RADIOLOGY, 2019, 16 (04)
  • [39] Impact of thyroid nodule sizes on the diagnostic performance of Korean thyroid imaging reporting and data system and contrast-enhanced ultrasound
    Zhao, Huaqun
    Liu, Xueling
    Lei, Bei
    Cheng, Ping
    Li, Jian
    Wu, Yedong
    Ma, Zhen
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2019, 72 (03) : 317 - 326
  • [40] Contrast-enhanced ultrasound (CEUS) liver imaging reporting and data system (LI-RADS) 2017 - a review of important differences compared to the CT/MRI system
    Kim, Tae Kyoung
    Noh, Seung Yeon
    Wilson, Stephanie R.
    Kono, Yuko
    Piscaglia, Fabio
    Jang, Hyun-Jung
    Lyshchik, Andrej
    Dietrich, Christoph F.
    Willmann, Juergen K.
    Vezeridis, Alexander
    Sirlin, Claude B.