Impact of marathon running on cardiac structure and function in recreational runners

被引:76
|
作者
Whyte, G
George, K
Shave, R
Dawson, E
Stephenson, C
Edwards, B
Gaze, D
Oxborough, D
Forster, J
Simspon, R
机构
[1] Northwick Pk Hosp & Clin Res Ctr, Olymp Med Inst, Harrow HA1 3UJ, Middx, England
[2] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Liverpool, Merseyside, England
[3] Brunel Univ, Dept Sport Sci, Uxbridge UB8 3PH, Middx, England
[4] Rigshosp, Dept Anaesthesia, Copenhagen, Denmark
[5] St George Hosp, Sch Med, Dept Chem Pathol, London SW17 0RE, England
[6] Nuffield Hosp, Dept Echocardiog, Leeds LS1 3EB, W Yorkshire, England
[7] Siemens Ltd, Bracknell RG12 8FZ, Berks, England
[8] Napier Univ, Dept Sports Sci, Edinburgh EH10 5DT, Midlothian, Scotland
关键词
cardiac troponin T; echocardiography; marathon; tissue Doppler imaging; reactive oxygen species;
D O I
10.1042/CS20040186
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The present study examined the relationship between LV (left ventricular) function, markers of cardiac-specific damage and markers of oxidative stress in recreational runners following a marathon. Runners (n = 52; 43 male and nine female; age, 35 +/- 10 years; height, 1.74 +/- 0.08 m; body mass, 75.9 +/- 8.9 kg) were assessed pre- and immediately post-marathon. LV function was assessed using standard M-mode two-dimensional Doppler echocardiography and TDI (tissue-Doppler imaging) echocardiography. Serum was analysed for cTnT (cardiac troponin-T), TEAC (Trolox equivalent antioxidant capacity; a measure of total antioxidant capacity), MDA (malondeal-dehyde) and 4-HNE (4-hydroxynonenal). A strong relationship was observed between standard and TDI echocardiography for all functional measures. Diastolic function was altered post-marathon characterized by a reduction in E (peak early diastolic filling. 0.79 +/- 0.11 compared with 0.64 +/- 0.16 cm/s; P < 0.001), an increase in A (peak late diastolic filling: 0.48 +/- 0.11 compared with 0.60 +/- 0.12 cm/s; P < 0.001) and a resultant decrease in E/A (ratio of E to A; 1.71 +/- 0.48 compared with 1.10 +/- 0.3 1; P < 0.001). Ejection fraction remained unchanged post-marathon. Thirty-two runners presented with cTnT values above the lower limit of detection for the assay (0.01 mug/l), and 20 runners presented post-marathon with cTnT values above the acute myocardial infarction cut-off value (0.05 mug/l). No significant correlations were observed between cTnT and any functional measurements. MDA (2.90 +/- 1.58 compared with 3.59 +/- 1.47 mumol/l) and TEAC (1.80 +/- 0.12 compared with 1.89 +/- 0.21 mmol/l) were significantly increased post-marathon, but were unrelated to changes in function or cTnT In conclusion, the present study demonstrated a reduction in diastolic function and widespread evidence of minimal cardiac damage following a marathon in recreational runners. The mechanism(s) underpinning the altered function and appearance of cTnT appear unrelated to reactive oxygen species.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 50 条
  • [21] Comparison of Running Economy Between Sexes in Ultra-Marathon Runners and Marathon Runners
    Streeper, Laura Christine
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 782 - 782
  • [22] Cardiac Troponin T: Only Small Molecules in Recreational Runners After Marathon Completion
    Vroemen, Wim H. M.
    Mezger, Stephanie T. P.
    Masotti, Silvia
    Clerico, Aldo
    Bekers, Otto
    de Boer, Douwe
    Mingels, Alma
    [J]. JOURNAL OF APPLIED LABORATORY MEDICINE, 2019, 3 (05): : 909 - 911
  • [23] Cardiac and renal function in a large cohort of amateur marathon runners
    Hewing, Bernd
    Schattke, Sebastian
    Spethmann, Sebastian
    Sanad, Wasiem
    Schroeckh, Sabrina
    Schimke, Ingolf
    Halleck, Fabian
    Peters, Harm
    Brechtel, Lars
    Lock, Juergen
    Baumann, Gert
    Dreger, Henryk
    Borges, Adrian C.
    Knebel, Fabian
    [J]. CARDIOVASCULAR ULTRASOUND, 2015, 13
  • [24] Cardiac Output and Performance during a Marathon Race in Middle-Aged Recreational Runners
    Billat, Veronique L.
    Petot, Helene
    Landrain, Morgan
    Meilland, Renaud
    Koralsztein, Jean Pierre
    Mille-Hamard, Laurence
    [J]. SCIENTIFIC WORLD JOURNAL, 2012,
  • [25] Cardiac and renal function in a large cohort of amateur marathon runners
    Bernd Hewing
    Sebastian Schattke
    Sebastian Spethmann
    Wasiem Sanad
    Sabrina Schroeckh
    Ingolf Schimke
    Fabian Halleck
    Harm Peters
    Lars Brechtel
    Jürgen Lock
    Gert Baumann
    Henryk Dreger
    Adrian C Borges
    Fabian Knebel
    [J]. Cardiovascular Ultrasound, 13
  • [26] The impact of exercise intensity on the release of cardiac biomarkers in marathon runners
    Alejandro Legaz-Arrese
    Keith George
    Luis Enrique Carranza-García
    Diego Munguía-Izquierdo
    Teresa Moros-García
    Enrique Serrano-Ostáriz
    [J]. European Journal of Applied Physiology, 2011, 111 : 2961 - 2967
  • [27] The impact of exercise intensity on the release of cardiac biomarkers in marathon runners
    Legaz-Arrese, Alejandro
    George, Keith
    Enrique Carranza-Garcia, Luis
    Munguia-Izquierdo, Diego
    Moros-Garcia, Teresa
    Serrano-Ostariz, Enrique
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (12) : 2961 - 2967
  • [28] Sex differences in cardiovascular adaptations in recreational marathon runners
    Jacqueline A. Augustine
    Wesley K. Lefferts
    Jacob P. DeBlois
    Tiago V. Barreira
    Beth A. Taylor
    Kan Liu
    Kevin S. Heffernan
    [J]. European Journal of Applied Physiology, 2021, 121 : 3459 - 3472
  • [29] Tiredness, Fatigue, and Exhaustion as Perceived by Recreational Marathon Runners
    Olson, Karin
    Zimka, Oksana
    Pasiorowski, Ashley
    Iregbu, Sandra
    Boule, Normand G.
    [J]. QUALITATIVE HEALTH RESEARCH, 2018, 28 (13) : 1997 - 2010
  • [30] Sex differences in cardiovascular adaptations in recreational marathon runners
    Augustine, Jacqueline A.
    Lefferts, Wesley K.
    DeBlois, Jacob P.
    Barreira, Tiago, V
    Taylor, Beth A.
    Liu, Kan
    Heffernan, Kevin S.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (12) : 3459 - 3472