Direct measurement of Lubberts effect in CsI: Tl scintillators using single x-ray photon imaging

被引:7
|
作者
Howansky, Adrian [1 ]
Lubinsky, A. R. [1 ]
Ghose, S. K. [2 ]
Suzuki, Katsuhiko [3 ]
Zhao, Wei [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Hlth Sci Ctr L4 120, Stony Brook, NY USA
[2] Brookhaven Natl Lab, Photon Sci, Upton, NY 11793 USA
[3] Hamamatsu Photon KK, Iwata City, Shizuoka, Japan
关键词
scintillator; flat panel detector; Lubberts; cesium iodide; spatial resolution; modulation transfer function; digital radiography; synchrotron; DETECTIVE QUANTUM EFFICIENCY; DIGITAL RADIOGRAPHY; SCREENS;
D O I
10.1117/12.2255561
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The imaging performance of an indirect flat panel detector (I-FPD) is fundamentally limited by that of its scintillator. The scintillator's modulation transfer function (MTF) varies as a function of the depth of x-ray interaction in the layer, due to differences in the lateral spread of light before detection by the optical sensor. This variation degrades the spatial frequency-dependent detective quantum efficiency (DQE(f) of I-FPDs, and is quantified by the Lubberts effect. The depth-dependent MTFs of various scintillators used in I-FPDs have been estimated using Monte Carlo simulations, but have never been measured directly. This work presents the first experimental measurements of the depth-dependent MTF of thallium-doped cesium iodide (CsI) and terbium-doped Gd2O2S (GOS) scintillators with thickness ranging from 200 1000 mu m. Light bursts from individual x-ray interactions occurring at known, fixed depths within a scintillator are imaged using an ultra-high-sensitivity II-EMCCD (image-intensifier, electron multiplying charge coupled device) camera. X-ray interaction depth in the scintillator is localized using a micro-slit beam of parallel synchrotron radiation (32 keV), and varied by translation in 50 +/- 1 mu m depth intervals. Fourier analysis of the imaged light bursts is used to deduce the MTF versus x-ray interaction depth z. Measurements of MTF(z,f) are used to calculate presampling MTF(f) with RQA-M3, RQA5 and RQA9 beam qualities and compared with conventional slanted edge measurements. Images of the depth-varying light bursts are used to derive each scintillator's Lubberts function for a 32 keV beam.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] SPECTRAL CHARACTERISTICS OF CSI-TL X-RAY LUMINOPHOR
    SMOLSKAYA, LP
    KOLESNIKOVA, TA
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1977, 41 (07): : 1409 - 1412
  • [32] Gigahertz (GHz) hard X-ray imaging using fast scintillators
    Wang, Zhehui
    Guardincerri, Elena
    Rathman, D. D.
    Azzouz, M. E.
    Barnes, Cris W.
    Berger, R.
    Bond, E. M.
    Craig, D. M.
    Holtkamp, David
    Kapustinsky, J. S.
    Klimenko, Alexei V.
    Kwiatkowski, K.
    Merl, R. B.
    Morris, C. L.
    Perry, J. O.
    Ramberg, E.
    Reich, R. K.
    Ronzhin, A.
    Warner, K.
    Williams, R. T.
    Zhu, Ren-Yuan
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [33] Comparative evaluation of single crystal scintillators under x-ray imaging conditions
    Valais, I. G.
    David, S.
    Michail, C.
    Nomicos, C. D.
    Panayiotakis, G. S.
    Kandarakis, I. S.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [34] Single crystal lutetium oxide thin film scintillators for X-ray imaging
    Riva, F.
    Martin, T.
    Douissard, P. A.
    Dujardin, C.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [35] Spectral X-ray imaging with single photon processing detectors
    Frojdh, C.
    Norlin, B.
    Frojdh, E.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [36] Perovskite: Scintillators, direct detectors, and X-ray imagers
    Jana, Atanu
    Cho, Sangeun
    Patil, Supriya A.
    Meena, Abhishek
    Jo, Yongcheol
    Sree, Vijaya Gopalan
    Park, Youngsin
    Kim, Hyungsang
    Im, Hyunsik
    Taylor, Robert A.
    MATERIALS TODAY, 2022, 55 : 110 - 136
  • [37] Influence of Si wall thickness of CsI(Tl) micro-square-frustums on the performance of the structured CsI(Tl) scintillation screen in X-ray imaging
    Zhixiang Sun
    Mu Gu
    Xiaolin Liu
    Bo Liu
    Juannan Zhang
    Shiming Huang
    Chen Ni
    Scientific Reports, 12
  • [38] Spectroscopic X-Ray Imaging Using a Pixelated Detector with Single Photon Processing Readout
    Norlin, Borje
    Frojdh, Erik
    Krapohl, David
    Frojdh, Anna
    Thungstrom, Goran
    Frojdh, Christer
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1074 - 1078
  • [39] Influence of Si wall thickness of CsI(Tl) micro-square-frustums on the performance of the structured CsI(Tl) scintillation screen in X-ray imaging
    Sun, Zhixiang
    Gu, Mu
    Liu, Xiaolin
    Liu, Bo
    Zhang, Juannan
    Huang, Shiming
    Ni, Chen
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [40] Imaging of muon track in CsI(Tl) crystal with single photon sensitive camera
    Wang, Zhimin
    Li, Min
    Wu, Diru
    Liu, Jinchang
    Zhang, Yongpeng
    Meng, Xiangcheng
    Liu, Caimei
    Yang, Changgen
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)