The use of model selection in the model-free analysis of protein dynamics

被引:112
|
作者
d'Auvergne, EJ [1 ]
Gooley, PR [1 ]
机构
[1] Univ Melbourne, Dept Biochem & Mol Biol, Melbourne, Vic 3010, Australia
关键词
AIC; model-free analysis; model selection; NMR relaxation; protein dynamics;
D O I
10.1023/A:1021902006114
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Model-free analysis of NMR relaxation data, which is widely used for the study of protein dynamics, consists of the separation of the global rotational diffusion from internal motions relative to the diffusion frame and the description of these internal motions by amplitude and timescale. Five model-free models exist, each of which describes a different type of motion. Model-free analysis requires the selection of the model which best describes the dynamics of the NH bond. It will be demonstrated that the model selection technique currently used has two significant flaws, under-fitting, and not selecting a model when one ought to be selected. Under-fitting breaks the principle of parsimony causing bias in the final model-free results, visible as an overestimation of S-2 and an underestimation Of tau(e) and R-ex. As a consequence the protein falsely appears to be more rigid than it actually is. Model selection has been extensively developed in other fields. The techniques known as Akaike's Information Criteria (AIC), small sample size corrected AIC (AICc), Bayesian Information Criteria (BIC), bootstrap methods, and cross-validation will be compared to the currently used technique. To analyse the variety of techniques, synthetic noisy data covering all model-free motions was created. The data consists of two types of three-dimensional grid, the R-ex grids covering single motions with chemical exchange {S-2, tau(e), R-ex}, and the Double Motion grids covering two internal motions {S-f(2), S-s(2), tau(s)}. The conclusion of the comparison is that for accurate model-free results, AIC model selection is essential. As the method neither under, nor over-fits, AIC is the best tool for applying Occam's razor and has the additional benefits of simplifying and speeding up model-free analysis.
引用
收藏
页码:25 / 39
页数:15
相关论文
共 50 条
  • [41] Model-free kinetic analysis of epoxy cures
    Vyazovkin, S
    Sbirrazzuoli, N
    ANTEC 2000: SOCIETY OF PLASTICS ENGINEERS TECHNICAL PAPERS, CONFERENCE PROCEEDINGS, VOLS I-III, 2000, : 832 - 839
  • [42] Model-free sampling
    Beer, Michael
    STRUCTURAL SAFETY, 2007, 29 (01) : 49 - 65
  • [43] Model-free control
    Fliess, Michel
    Join, Cedric
    INTERNATIONAL JOURNAL OF CONTROL, 2013, 86 (12) : 2228 - 2252
  • [44] Multiple Loci Mapping via Model-free Variable Selection
    Sun, Wei
    Li, Lexin
    BIOMETRICS, 2012, 68 (01) : 12 - 22
  • [45] Feature subset selection applied to model-free gait recognition
    Dupuis, Y.
    Savatier, X.
    Vasseur, P.
    IMAGE AND VISION COMPUTING, 2013, 31 (08) : 580 - 591
  • [46] Model-Free Variable Selection With Matrix-Valued Predictors
    Li, Zeda
    Dong, Yuexiao
    JOURNAL OF COMPUTATIONAL AND GRAPHICAL STATISTICS, 2021, 30 (01) : 171 - 181
  • [47] Meta-analysis for model-free methods
    Gu, C
    Province, MA
    Rao, DC
    GENETIC DISSECTION OF COMPLEX TRAITS, 2001, 42 : 255 - 272
  • [48] Contemporary Model-Free Methods for Linkage Analysis
    Almasy, Laura
    Blangero, John
    GENETIC DISSECTION OF COMPLEX TRAITS, 2ND EDITION, 2008, 60 : 175 - 193
  • [50] Model-free metacognition
    Carruthers, Peter
    Williams, David M.
    COGNITION, 2022, 225