Reduced graphene oxide as an efficient sorbent in microextraction by packed sorbent: Determination of local anesthetics in human plasma and saliva samples utilizing liquid chromatography-tandem mass spectrometry

被引:12
|
作者
Ahmadi, Mazaher [1 ]
Moein, Mohammad Mahdi [2 ,3 ]
Madrakian, Tayyebeh [1 ]
Afkhami, Abbas [1 ]
Bahar, Soleiman [4 ]
Abdel-Rehim, Mohamed [2 ,3 ,5 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan, Iran
[2] Karolinska Inst, Ctr Psychiat Res, Dept Clin Neurosci, SE-17176 Stockholm, Sweden
[3] Stockholm Cty Council, SE-17176 Stockholm, Sweden
[4] Univ Kurdistan, Fac Sci, Dept Chem, Sanandaj, Iran
[5] KTH Royal Inst Technol, Div Mat & Nanofys MNF, Stockholm, Sweden
关键词
Local anesthetics; Microextraction by packed sorbent; Reduced graphene oxide; LC-MS/MS; Plasma; Saliva; SOLID-PHASE EXTRACTION; GAS-CHROMATOGRAPHY; ONLINE MICROEXTRACTION; POLYSULFONE MEMBRANE; DRUGS; NANOMATERIALS; BIOANALYSIS; MEPS;
D O I
10.1016/j.jchromb.2018.07.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, reduced graphene oxide (RGO) has been utilized as an efficient sorbent in microextraction by packed sorbent (MEPS). The combination of MEPS and liquid chromatography-tandem mass spectrometry has been used to develop a method for the extraction and determination of three local anesthetics (i.e. lidocaine, prilocaine, and ropivacaine) in human plasma and saliva samples. The results showed that the utilization of RGO in MEPS could minimize the matrix effect so that no interfering peaks at the retention times of the analytes or internal standard was observed. The high extraction efficiency of this method was approved by mean recoveries of 97.26-106.83% and 95.21-105.83% for the studied analytes in plasma and saliva samples, respectively. Intra- and inter-day accuracies and precisions for all analytes were in good accordance with the international regulations. The accuracy values (as percentage deviation from the nominal value) of the quality control samples were between - 2.1 to 13.9 for lidocaine, - 4.2 to 11.0 for prilocaine and between - 4.5 to - 2.4 for ropivacaine in plasma samples while the values were ranged from - 4.6 to 1.6 for lidocaine, from - 4.2 to 15.5 for prilocaine and from - 3.3 to - 2.3 for ropivacaine in human saliva samples. Lower and upper limit of quantification (LLOQ, ULOQ) were set at 5 and 2000 nmol L-1 for all of the studied drugs. The correlation coefficients values were >= 0.995. The limit of detection values were obtained 4 nmol L-1 for lidocaine and prilocaine, and 2 nmol L-1 for ropivacaine.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [31] Determination of amphetamines in hair samples using microextraction by packed sorbent and gas chromatography-mass spectrometry
    Pires, Bruno
    Simao, Ana Y.
    Rosado, Tiago
    Barroso, Mario
    Gallardo, Eugenia
    DRUG TESTING AND ANALYSIS, 2024,
  • [32] The Determination of Cannabinoids in Urine Samples Using Microextraction by Packed Sorbent and Gas Chromatography-Mass Spectrometry
    Rosendo, Luana M.
    Rosado, Tiago
    Oliveira, Patrik
    Simao, Ana Y.
    Margalho, Claudia
    Costa, Suzel
    Passarinha, Luis A.
    Barroso, Mario
    Gallardo, Eugenia
    MOLECULES, 2022, 27 (17):
  • [33] Microextraction by packed sorbent and high-performance liquid chromatography for determination of benznidazole in human plasma
    Diniz, Melina Luiza Vieira
    Batista, Jessica Mauricio
    da Silva, Pedro Henrique Reis
    Fernandes, Christian
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1219
  • [34] Microextraction in Packed Sorbent for Determination of Sulfonamides in Egg Samples by Liquid Chromatography and Spectrophotometric Detection
    Salami, Fernanda H.
    Queiroz, Maria Eugenia C.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (09) : 1656 - 1661
  • [35] Polyacrylonitrile / graphene oxide nanofibers for packed sorbent microextraction of drugs and their metabolites from human plasma samples
    Karimiyan, Hanieh
    Uheida, Abdusalam
    Hadjmohammadi, Mohammadreza
    Moein, Mohammad Mandi
    Abdel-Rehim, Mohamed
    TALANTA, 2019, 201 : 474 - 479
  • [36] Quantitative Measurement of Plasma Free Metanephrines by a Simple and Cost-Effective Microextraction Packed Sorbent with Porous Graphitic Carbon and Liquid Chromatography-Tandem Mass Spectrometry
    Xiong, Xin
    Zhang, Yuanyuan
    Zhao, Rongsheng
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2021, 2021
  • [37] Determination of eptifibatide concentration in human plasma utilizing the liquid chromatography-tandem mass spectrometry method
    Liu, Jia
    Duan, Xiaotao
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 527 - 532
  • [38] Microextraction in packed syringe/liquid chromatography/electrospray tandem mass spectrometry for quantification of olomoucine in human plasma samples
    Abdel-Rehim, M
    Skansen, P
    Vita, M
    Hassan, Z
    Blomberg, L
    Hassan, M
    ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) : 35 - 39
  • [39] A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples
    Peste, Gabriela
    Bibire, Nela
    Apostu, Mihai
    Vlase, Aurel
    Oniscu, Corneliu
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2009,
  • [40] Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry
    Lee, HW
    Ji, HY
    Kim, HH
    Cho, HY
    Lee, YB
    Lee, HS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02): : 395 - 400