Nonlinear Biomechanical Characteristics of the Schneiderian Membrane: Experimental Study and Numerical Modeling

被引:6
|
作者
Zhai, Min [1 ,2 ]
Cheng, Haode [1 ]
Yuan, Jing [1 ]
Wang, Xin [1 ]
Li, Bing [3 ]
Li, Dehua [1 ]
机构
[1] Fourth Mil Med Univ, Shaanxi Engn Res Ctr Dent Mat & Adv Manufacture, State Key Lab Mil Stomatol,Sch Stomatol, Natl Clin Res Ctr Oral Dis,Dept Oral Implants, Xian 710032, Shaanxi, Peoples R China
[2] Tibet Mil Area Command, Gen Hosp, Dept Stomatol, Lhasa 850007, Tibet, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710032, Shaanxi, Peoples R China
关键词
FINITE-ELEMENT-ANALYSIS; SINUS FLOOR ELEVATION; HUMAN PERIODONTAL-LIGAMENT; POSTERIOR MAXILLA; CLINICAL-IMPLICATIONS; RISK-FACTORS; AUGMENTATION; PERFORATION; THICKNESS; BEHAVIOR;
D O I
10.1155/2018/2829163
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective. The aim of this study is to quantify the nonlinear mechanical behavior of the Schneiderian membrane. Methods. Thirty cadaveric maxillary sinus membrane specimens were divided into the elongation testing group and the perforation testing group. Mechanical experimental measurements were taken via ex vivo experiments. Theoretical curves were compared with experimental findings to assess the effectiveness of the nonlinear mechanical properties. The FE model with nonlinear mechanical properties was used to simulate the detachment of the Schneiderian membrane under loading. Results. The mean thickness of the membrane samples was 1.005 mm. The mean tensile strength obtained by testing was 6.81 N/mm(2). In membrane perforation testing, the mean tensile strength and the linear elastic modulus were significantly higher than those in membrane elongation testing (P < 0.05). The mean adhesion force between the Schneiderian membrane and the bone was 0.052 N/mm. By FE modeling, the squared correlation coefficients of theoretical stress-strain curves for the nonlinear and linear models were 0.99065 and 0.94656 compared with the experimental data. Conclusions. The biomechanical properties of the Schneiderian membrane were implemented into the FE model, which was applied to simulate the mechanical responses of the Schneiderian membrane in sinus floor elevation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] In Vitro experimental studies and numerical modeling to investigate the biomechanical effects of surgical interventions on the spine
    Ruspi M.L.
    Chehrassan M.
    Faldini C.
    Cristofolini L.
    Critical Reviews in Biomedical Engineering, 2019, 47 (04) : 295 - 321
  • [22] The Schneiderian Membrane Contains Osteoprogenitor Cells: In Vivo and In Vitro Study
    Srouji, S.
    Kizhner, T.
    Ben David, D.
    Riminucci, M.
    Bianco, P.
    Livne, E.
    CALCIFIED TISSUE INTERNATIONAL, 2009, 84 (02) : 138 - 145
  • [23] Analytical and numerical study of nonlinear effects at tsunami modeling
    Zahibo, N
    Pelinovsky, E
    Talipova, T
    Kozelkov, A
    Kurkin, A
    APPLIED MATHEMATICS AND COMPUTATION, 2006, 174 (02) : 795 - 809
  • [24] Hybrid (Numerical-Experimental) Modeling of an Experimental Vehicle Model with Linear and Nonlinear Components
    Giagopoulos, D.
    Theodosiou, C.
    Natsiavas, S.
    STRUCTURAL HEALTH MONITORING 2010, 2010, : 1089 - 1096
  • [25] A numerical study of a nonlinear system arising in modeling of ferromagnets
    Cerimele, MM
    Pistella, F
    Valente, V
    NONLINEAR ANALYSIS-THEORY METHODS & APPLICATIONS, 2001, 47 (05) : 3357 - 3367
  • [26] Experimental Study of the Biomechanics of Maxillary Implants under Conditions of Biomechanical Modeling
    Olesova, V. N.
    Amkhadova, M. A.
    Zaslavskii, S. A.
    Olesov, E. E.
    Shashmurina, V. R.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2019, 166 (04) : 522 - 526
  • [27] Experimental Study of the Biomechanics of Maxillary Implants under Conditions of Biomechanical Modeling
    V. N. Olesova
    M. A. Amkhadova
    S. A. Zaslavskii
    E. E. Olesov
    V. R. Shashmurina
    Bulletin of Experimental Biology and Medicine, 2019, 166 : 522 - 526
  • [28] Evaluation of the Characteristics and Association Between Schneiderian Membrane Thickness and Nasal Septum Deviation
    Bayrak, Seval
    Ustaoglu, Guelbahar
    Demiralp, Kemal Ozguer
    Cakmak, Emine Sebnem Kursun
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (03) : 683 - 687
  • [29] Schneiderian membrane perforation repair using a crosslinked collagen membrane: a retrospective cohort study
    Masri, Daya
    Jonas, Ehud
    Ghanaiem, Omar
    Chaushu, Liat
    HEAD & FACE MEDICINE, 2025, 21 (01)
  • [30] Characteristics of head frequency response in blunt impacts: a biomechanical modeling study
    Li, Guibing
    Xu, Shengkang
    Xiong, Tao
    Li, Kui
    Qiu, Jinlong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12