Three-Dimensional Accuracy of a Digitally Coded Healing Abutment Implant Impression System

被引:16
|
作者
Ng, Simon D. [1 ]
Tan, Keson B. [2 ]
Teoh, K. H. [1 ]
Cheng, Ansgar C. [2 ]
Nicholls, Jack I. [3 ]
机构
[1] Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore
[2] Natl Univ Singapore, Fac Dent, Singapore 119083, Singapore
[3] Univ Washington, Sch Dent, Dept Restorat Dent, Seattle, WA 98195 USA
关键词
accuracy; coordinate measuring machine; digital measurement; implant impressions; three-dimensional measurement; SUPPORTED PROSTHESES; RESTORATION; CONNECTION; DENTISTRY; DESIGN;
D O I
10.11607/jomi.3433
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. Materials and Methods: Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. Results: Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. Conclusions: Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.
引用
收藏
页码:927 / 936
页数:10
相关论文
共 50 条
  • [21] Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: Three-dimensional finite element analysis
    Yamanishi, Yasufumi
    Yamaguchi, Satoshi
    Imazato, Satoshi
    Nakano, Tamaki
    Yatani, Hirofumi
    DENTAL MATERIALS, 2012, 28 (11) : 26 - 33
  • [22] A novel technique using a coded healing abutment for the fabrication of a CAD/CAM titanium abutment for an implant-supported restoration
    Grossmann, Y
    Pasciuta, M
    Finger, IM
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03): : 258 - 261
  • [23] The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template
    Matta, Ragai-Edward
    Bergauer, Bastian
    Adler, Werner
    Wichmann, Manfred
    Nickenig, Hans-Joachim
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 804 - 808
  • [24] Three-dimensional accuracy of different correction methods for cast implant bars
    Kwon, Ji-Yung
    Kim, Chang-Whe
    Lim, Young-Jun
    Kwon, Ho-Beom
    Kim, Myung-Joo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01): : 39 - 45
  • [25] Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies
    Tan, Janice Zhi Hui
    Tan, Ming Yi
    Toh, Yoong Liang See
    Wong, Kuan Yee
    Tan, Keson Beng Choon
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 735 - 744
  • [26] Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection
    Cho, Sung-Yong
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (03) : E49 - E58
  • [27] Passive fit and accuracy of three dental implant impression techniques
    Al Quran, Firas A.
    Rashdan, Bashar A.
    Abu Zomar, AbdelRahman A.
    Weiner, Saul
    QUINTESSENCE INTERNATIONAL, 2012, 43 (02): : 119 - 125
  • [28] AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS
    Al-Abdullah, Khaled
    Zandparsa, Roya
    Finkelman, Matthew
    Hirayama, Hiroshi
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02): : 90 - 100
  • [29] Effects of Implant System, Impression Technique, and Impression Material on Accuracy of the Working Cast
    Wegner, Kerstin
    Weskott, Katharina
    Zenginel, Martha
    Rehmann, Peter
    Woestmann, Bernd
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (04) : 989 - 995
  • [30] Evaluation of the accuracy of three techniques used for multiple implant abutment impressions
    Vigolo, P
    Majzoub, Z
    Cordioli, G
    JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (02): : 186 - 192