In situ monitoring Ni electrodeposition and stripping on gold electrode surface in a static magnetic field using an electrochemical quartz crystal impedance system

被引:11
|
作者
Zhang, Youyu [1 ]
Liu, Meiling [1 ]
Wang, Meiling [1 ]
Xie, Qingji [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Peoples R China
基金
中国国家自然科学基金;
关键词
magnetically assisted Ni electrodeposition; piezoelectric quartz crystal impedance; gold electrode; electrochemical dissolution;
D O I
10.1016/j.snb.2006.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The processes of nickel electrochemical deposition and stripping on a gold electrode surface in a solution of low Ni2+ concentration with or without magnetic field were monitored in situ using an electrochemical quartz crystal impedance system (EQCIS). The effects of magnetic field on the piezoelectric quartz crystal (PQC) responses were investigated in air and in electrolytic solution. The PQC responses were monitored in four steps, namely, Ni electrodeposition and Ni magnetic activation; magnetically assisted Ni electrodeposition; Ni dissolution under open-circuit potential; Ni electro-stripping, respectively. From the electrochemical quartz crystal responses, it was observed that static magnetic field significantly affected the processes of nickel electrochemical deposition and stripping after multilayer Ni deposited on gold electrode surface. But the effects of magnetic field on the Ni electrodeposition on diamagnetic An electrode were insensible at the initial stage. The experimental results also suggested that ferromagnetic metal-Ni could be magnetized, Ni electrodeposition rate was accelerated after multilayer Ni deposition on An electrode, and the stripping rate of the deposited Ni was slowed down in the presence of magnetic field. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:444 / 453
页数:10
相关论文
共 50 条
  • [41] Electrodeposition study of simulated and dissolution solutions of the positive electrode of a spent Ni-MH battery using the electrochemical quartz crystal microbalance and inductively coupled plasma optical emission spectrometry
    P.V.M. Dixini
    V.C.B. Pegoretti
    V.G. Celante
    F.S. Betim
    M.B.J.G. Freitas
    Ionics, 2017, 23 : 3235 - 3243
  • [42] Electrodeposition study of simulated and dissolution solutions of the positive electrode of a spent Ni-MH battery using the electrochemical quartz crystal microbalance and inductively coupled plasma optical emission spectrometry
    Dixini, P. V. M.
    Pegoretti, V. C. B.
    Celante, V. G.
    Betim, F. S.
    Freitas, M. B. J. G.
    IONICS, 2017, 23 (11) : 3235 - 3243
  • [43] Newly developed real time monitoring system for ionic migration by means of quartz crystal microbalance (QCM)and electrochemical impedance spectroscopy(EIS).
    Yoshihara, S
    ADVANCES IN ELECTRONIC PACKAGING 2003, VOL 1, 2003, : 735 - 739
  • [44] Estimation of the surface area of a screen-printed carbon electrode modified with gold nanoparticles and cysteine using electrochemical impedance spectroscopy
    Noh T.U.
    Aziz A.A.
    Chemical Engineering Transactions, 2018, 63 : 529 - 534
  • [45] A comparative study on the viscoelasticity and morphology of polyaniline films galvanostatically grown on bare and 4-aminothiophenol-modified gold electrodes using an electrochemical quartz crystal impedance system and SEM
    Xie, QJ
    Zhang, YY
    Xiang, CH
    Tang, JX
    Li, YL
    Zhao, QX
    Yao, SZ
    ANALYTICAL SCIENCES, 2001, 17 (05) : 613 - 620
  • [46] A Comparative Study on the Viscoelasticity and Morphology of Polyaniline Films Galvanostatically Grown on Bare and 4-Aminothiophenol-Modified Gold Electrodes Using an Electrochemical Quartz Crystal Impedance System and SEM
    Qingji Xie
    Youyu Zhang
    Canhui Xiang
    Jianxin Tang
    Yunlong Li
    Qiuxiang Zhao
    Shouzhuo Yao
    Analytical Sciences, 2001, 17 : 613 - 620
  • [47] Enhancement of radio frequency magnetic field for a 1.5 T magnetic resonance system using a high impedance surface
    Issa, Ismail
    Ford, Kenneth Lee
    Rao, Madhwesha
    Wild, James
    IET MICROWAVES ANTENNAS & PROPAGATION, 2016, 10 (13) : 1378 - 1383
  • [48] In-situ monitoring of potential enhanced DNA related processes using electrochemical quartz crystal microbalance with dissipation (EQCM-D)
    Quan, Xueling
    Heiskanen, Arto
    Tenje, Maria
    Boisen, Anja
    ELECTROCHEMISTRY COMMUNICATIONS, 2014, 48 : 111 - 114
  • [49] ELECTROCHEMICAL DEPOSITION AND STRIPPING OF COPPER, NICKEL AND COPPER-NICKEL ALLOY THIN-FILMS AT A POLYCRYSTALLINE GOLD SURFACE - A COMBINED VOLTAMMETRY-COULOMETRY-ELECTROCHEMICAL QUARTZ-CRYSTAL MICROGRAVIMETRY STUDY
    ZHOU, M
    MYUNG, N
    CHEN, X
    RAJESHWAR, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 398 (1-2): : 5 - 12
  • [50] Gravimetric monitoring of adsorption behavior of tetrakis(methylpyridiniumyl)porphyrin onto quartz crystal surface using an electrode-separated piezoelectric sensor
    Shen, DZ
    Xie, QJ
    Kang, Q
    Xue, YH
    MIKROCHIMICA ACTA, 1998, 128 (3-4) : 229 - 233