Design And Development Of An Innovative Sensor System For Non-Invasive Monitoring Of Athletic Performances

被引:2
|
作者
Sabatini, Anna [1 ]
Zompanti, Alessandro [1 ]
Grasso, Simone [1 ]
Gianfelici, Antonio [2 ]
Di Castro, Andrea [2 ]
Donatucci, Bruno [2 ]
Pennazza, Giorgio [1 ]
Santonico, Marco [1 ]
机构
[1] Campus Biomed Univ Rome, Unit Elect Sensor Syst, Rome, Italy
[2] CONI, Inst Sport Sci & Med, Rome, Italy
关键词
Athlete Performances; Smart Sensor System; BLE Connettivity; Non-Invasive Monitoring; LACTATE;
D O I
10.1109/metroi4.2019.8792863
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper shows a low-power, wireless and non invasive sensor system for the monitoring of athletic performances. This sensor will allow, for the first time, the evaluation of the anaerobic threshold analyzing only samples of saliva and exhaled breath in order to examine athletic performances with a non-invasive technique. The anaerobic threshold represents the capacity of the athlete to perform an extended exercise. This threshold is characterized by a massive activation of the anaerobic mechanism with the sudden production increase of carbon dioxide, respiratory acts and lactate level. These three figures are detectable by the presented sensor system.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 50 条
  • [21] Non-invasive micro system for urodynamic monitoring
    Zen, M
    Viarani, N
    Gottardi, M
    Guarnieri, V
    Margesin, B
    Paranjape, M
    Sensors for Environmental Control, 2003, : 142 - 146
  • [22] Non-invasive system for monitoring of the manufacturing equipment
    Mazare, A. G.
    Belu, N.
    Ionescu, L. M.
    Rachieru, N.
    Misztal, A.
    MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING V, 2017, 227
  • [23] Non-invasive system for continuous glucose monitoring
    Karasik, A.
    Herzenstein, O.
    Gabis, E.
    Weinstein, A.
    DIABETOLOGIA, 2008, 51 : S431 - S432
  • [24] Non-Invasive Heart Rate Monitoring System using Giant Magneto Resistance Sensor
    Kalyan, Kubera
    Chugh, Vinit Kumar
    Anoop, C. S.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4873 - 4876
  • [25] Design and Development of a Non-invasive Opto-Electronic Sensor for Blood Glucose Monitoring Using a Visible Light Source
    Alam, Iftekar
    Dunde, Anjaneyulu
    Balapala, Kartheek R.
    Gangopadhyay, Moumita
    Dewanjee, Saikat
    Mukherjee, Moutima
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [26] Optical Sensor System for Continuous Non-Invasive Hemodynamic Monitoring in Real-Time
    Timm, U.
    Andruschenko, S.
    Hinz, M.
    Koball, S.
    Leen, G.
    Lewis, E.
    Kraitl, J.
    Ewald, H.
    2011 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2011, : 167 - 172
  • [27] Synthesis and Biocompatibility Study of Hydrogel for Patch Sensor in Non-invasive Glucose Monitoring System
    Kwon, Jeong Woo
    Kim, Dong Chul
    Yoon, In Joon
    Jeong, Yoon Na
    Jeong, Ji Young
    Hwang, In Sik
    POLYMER-KOREA, 2009, 33 (02) : 111 - 117
  • [28] Non-invasive brain stimulation in athletic competition
    Mehrsafar, Amir Hossien
    Gazerani, Parisa
    APUNTS-MEDICINA DE L ESPORT, 2019, 54 (203): : 105 - 106
  • [29] A Sensor System for Automatic Detection of Food Intake Through Non-Invasive Monitoring of Chewing
    Sazonov, Edward S.
    Fontana, Juan M.
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1340 - 1348
  • [30] NON-INVASIVE MONITORING
    Turmelle, Michael
    JOURNAL OF HOSPITAL MEDICINE, 2010, 5 : 58 - 58