Molecularly imprinted poly(4-amino-5-hydroxy-2,7-naphthalenedisulfonic acid) modified glassy carbon electrode as an electrochemical theophylline sensor

被引:41
|
作者
Aswini, K. K. [1 ]
Mohan, A. M. Vinu [1 ]
Biju, V. M. [1 ]
机构
[1] Natl Inst Technol, Dept Chem, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Theophylline; Electrochemical sensor; Molecularly imprinted polymer; Electropolymerization; 4-Amino-5-hydroxy-2,7-naphthalenedisulfonic acid; PERFORMANCE LIQUID-CHROMATOGRAPHY; ULTRA-TRACE; ELECTROCATALYTIC OXIDATION; VOLTAMMETRIC BEHAVIOR; SELECTIVE EXTRACTION; GOLD NANOPARTICLES; AG NANOPARTICLES; URANYL IONS; POLYMER; HEMOGLOBIN;
D O I
10.1016/j.msec.2016.03.098
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Theophylline is an inexpensive drug employed in asthma and chronic obstructive pulmonary disorder medications and is toxic at higher concentration. The development of a molecularly imprinted polymer based theophylline electrochemical sensor on glassy carbon electrode by the electropolymerization of 4-amino-5-hydroxy-2,7-naphthalenedisulfonic acid is being discussed in this work. The MIP modification enhances the theophylline recognition ability and the electron transfer kinetics of the bare electrode. The parameters, controlling the performance of the imprinted polymer based sensor, like number of electropolymerization cycles, composition of the pre-polymerization mixture, pH and immersion time were investigated and optimized. The interaction energy and the most stable conformation of the template-monomer complex in the pre-polymerization mixture were determined computationally using ab initio calculations based on density functional theory. The amperometric measurements showed that the developed sensor has a method detection limit of 0.32 mu M for the dynamic range of 0.4 to 17 mu M, at optimized conditions. The transducer possesses appreciable selectivity in the presence of structurally similar interferents such as theobromine, caffeine and doxofylline. The developed sensor showed remarkable stability and reproducibility and was also successfully employed in theophylline detection from commercially available tablets. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 125
页数:10
相关论文
共 50 条
  • [21] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [22] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Huo, Hong Yu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 195 - 199
  • [23] Molecularly imprinted electrochemical sensor based on a reduced graphene modified carbon electrode for tetrabromobisphenol A detection
    Chen, Hong-Jun
    Zhang, Zhao-Hui
    Cai, Rong
    Kong, Xiang-Quan
    Chen, Xing
    Liu, Yu-Nan
    Yao, Shou-Zhuo
    ANALYST, 2013, 138 (09) : 2769 - 2776
  • [24] Poly(isonicotinic acid) modified glassy carbon electrode for electrochemical detection of norepinephrine
    Zhao, H
    Zhang, YZ
    Yuan, ZB
    ANALYTICA CHIMICA ACTA, 2002, 454 (01) : 75 - 81
  • [25] Rapid Detection of Perfluorodecanoic Acid and Perfluorooctanesulfonic Acid in Foods Using a Molecularly Imprinted Poly(o-phenylenediamine)/Modified Glassy Carbon Electrode
    Liu, Ting
    Sun, Bolu
    Sang, Chunyan
    Cai, Hua
    Liu, Hong
    Liu, Yuwei
    He, Gengsheng
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2025, 73 (13) : 8073 - 8083
  • [26] Trace anthracene electrochemical detection based on electropolymerized-molecularly imprinted polypyrrole modified glassy carbon electrode
    Mathieu-Scheers, Emilie
    Bouden, Sarra
    Grillot, Celine
    Nicolle, Jimmy
    Warmont, Fabienne
    Bertagna, Valerie
    Cagnon, Benoit
    Vautrin-Ul, Christine
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 848
  • [27] Electrochemical cholesterol sensor based on carbon nanotube@molecularly imprinted polymer modified ceramic carbon electrode
    Tong, Yuejin
    Li, Haidong
    Guan, Huaimin
    Zhao, Jianming
    Majeed, Saadat
    Anjum, Saima
    Liang, Feng
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 553 - 558
  • [28] Poly (4-Amino-3-Hydroxynaphthalene Sulfonic Acid)-Modified Glassy Carbon Electrode for Electrochemical Detection of Ephedrine in Human Urine
    Amare, Meareg
    Lakew, Worku
    Admassie, Shimelis
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (04): : 365 - 378
  • [29] An electrochemical sensor for paracetamol based on an electropolymerized molecularly imprinted o-phenylenediamine film on a multi-walled carbon nanotube modified glassy carbon electrode
    Peng, Youyuan
    Wu, Zhibo
    Liu, Zhigang
    ANALYTICAL METHODS, 2014, 6 (15) : 5673 - 5681
  • [30] Voltammetric lidocaine sensor by using a glassy carbon electrode modified with porous carbon prepared from a MOF, and with a molecularly imprinted polymer
    Junjie Zhang
    Jiang Liu
    Yang Zhang
    Feng Yu
    Fu Wang
    Zhengchun Peng
    Yingchun Li
    Microchimica Acta, 2018, 185