Comparative energy, exergy, environmental, exergoeconomic, and enviroeconomic analysis of building integrated photovoltaic/thermal, earth-air heat exchanger, and hybrid systems

被引:28
|
作者
Shahsavar, Amin [1 ]
Talebizadehsardari, Pouyan [2 ]
Arici, Muslum [3 ]
机构
[1] Kermanshah Univ Technol, Dept Mech Engn, Kermanshah, Iran
[2] Brunel Univ London, Inst Energy Futures, Ctr Sustainable Energy Use Food Chains, Uxbridge, Middx, England
[3] Kocaeli Univ, Engn Fac, Mech Engn Dept, Umuttepe Campus, TR-41001 Kocaeli, Turkey
关键词
Building integrated photovoltaic/thermal (BIPV/T); Earth-air heat exchanger (EAHE); Exergoeconomic; Enviroeconomic; Energy; Exergy; 5E analysis; PERFORMANCE; COLLECTORS; PV/T; PUMP;
D O I
10.1016/j.jclepro.2022.132510
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A comparative study is performed to assess a hybrid building integrated photovoltaic/thermal (BIPV/T) system and earth-air heat exchanger (EAHE) in comparison with individual BIPV/T and EAHE systems. Different systems are examined based on energy, exergy, environmental, exergoeconomic, and enviroeconomic analysis. The hybrid system is able to increase/decrease the outdoor air temperature in winter/summer and produce electricity. A parametric study is also performed to inspect the impact of geometrical and operational metrics on the exergoeconomic and enviroeconomic parameters of the hybrid system. The outcomes revealed that the hybrid device produces higher annual total thermal and electrical energies by almost 10.1% and 935.6% compared with the BIPV/T and EAHE systems, respectively. In addition, it was found that the hybrid system produces 3.2% less annual total thermal and electrical exergy compared with the BIPV/T unit. While the hybrid system's enviroeconomic parameter was 3.2% less than the BIPV/T unit, its exergoeconomic parameter was 51% higher than that for the BIPV/T system. The case study analysis indicated that the exergoeconomic parameter increases by enhancing the air mass flow rate and EAHE length. Furthermore, it was found that the enviroeconomic parameter increases for a higher length and width of the BIPV/T system.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Enhancing the thermal performance of an agricultural solar greenhouse by geothermal energy using an earth-air heat exchanger system: A review
    Dhaidan, Nabeel S.
    Al-Shohani, Wisam A. M.
    Abbas, Hawraa H.
    Rashid, Farhan Lafta
    Ameen, Arman
    Al-Mousawi, Fadhel N.
    Homod, Raad Z.
    GEOTHERMICS, 2024, 123
  • [42] Comprehensive energy, exergy, and environmental evaluation of integrated heat pipe photovoltaic/thermal systems using multi-objective optimization
    Ghasempour, Roghayeh
    Salehi, Mohammad
    Fakouriyan, Samaneh
    Applied Thermal Engineering, 2024, 257
  • [43] Energy and exergy analysis and multi-objective optimization of an air based building integrated photovoltaic/thermal (BIPV/T) system
    Khaki, Mahsa
    Shahsavar, Amin
    Khanmohammadi, Shoaib
    Salmanzadeh, Mazyar
    SOLAR ENERGY, 2017, 158 : 380 - 395
  • [44] Thermal performance of a nearly zero energy passive house integrated with the air-air heat exchanger and the earth-water heat exchanger
    Chel, Arvind
    Janssens, Arnold
    De Paepe, Michel
    ENERGY AND BUILDINGS, 2015, 96 : 53 - 63
  • [45] Performance boost of an integrated photovoltaic-thermal and solar thermal collectors using minichannel heat sink: Energy, exergy, and environmental analysis
    Alsibiani, Sameer Ali
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 54
  • [46] The use of earth-air heat exchanger and fuzzy logic control can reduce energy consumption and environmental concerns even more
    Diaz, S. E.
    Sierra, J. M. T.
    Herrera, J. A.
    ENERGY AND BUILDINGS, 2013, 65 : 458 - 463
  • [47] Energy, Exergy, Economic and Environmental analysis of Photovoltaic Thermal Systems for Absorption Cooling Application
    Adedeji, Michael J.
    Ruwa, Tonderai L.
    Abid, Muhammad
    Ratlamwala, Tahir A. H.
    Dagbasi, Mustafa
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 916 - 923
  • [48] Comparative analysis of earth to air heat exchanger configurations based on uniformity and thermal performance
    Qi, Di
    Li, Angui
    Li, Shixiong
    Zhao, Chuangyao
    APPLIED THERMAL ENGINEERING, 2021, 183
  • [49] Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions
    Agrawal, Basant
    Tiwari, G. N.
    APPLIED ENERGY, 2010, 87 (02) : 417 - 426
  • [50] Thermal performance prediction and energy conservation potential of earth air tunnel heat exchanger for thermal comfort in building
    Kaushik, S. C.
    Garg, Tarun
    Lal, Shiv
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (01)