The single-connector technique for initial placement of double-lumen tubes

被引:2
|
作者
Pfitzner, J [1 ]
Alexander, HI [1 ]
Hung, PK [1 ]
机构
[1] Queen Elizabeth Hosp, Dept Anaesthesia, Woodville, SA 5011, Australia
关键词
anaesthesia; one-lung; double-lumen tube; single-lung ventilation; complications; hyperinflation; ball-valve effect;
D O I
10.1177/0310057X0403200515
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Due to the presence of major lung or extra-pulmonary pathology, which may be unilateral or bilateral, the initial placement of a double-lumen tube is not always straightforward. Although fibreoptic bronchoscopy is often used to confirm "correct" placement, a "blind" technique is frequently used for the initial insertion. The currently widely taught blind technique involves tracheal cuff inflation and ventilation of both lungs as a first manoeuvre, with a subsequent assessment of single-lung ventilation by clamping off, in turn, the two limbs of the double-lumen tube double-connector An alternative approach involves the bronchial cuff being inflated first, and then using a single-connector to transfer ventilation from one lung to the other In this paper this technique is described and compared to the more traditional method. On a purely "number of steps" basis, the single-connector approach has several advantages. Furthermore, use of a technique that involves bronchial cuff inflation and single-lung ventilation as a first manoeuvre may reduce the risk of a temporarily malplaced double-lumen tube creating a potentially harmful ball-valve effect in a partially obstructed lobe or lung.
引用
收藏
页码:685 / 692
页数:8
相关论文
共 50 条
  • [31] Dimensions of double-lumen tracheobronchial tubes
    Russell, WJ
    Strong, TS
    ANAESTHESIA AND INTENSIVE CARE, 2003, 31 (01) : 50 - 53
  • [32] A view of and through double-lumen tubes
    Slinger, P
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (03) : 287 - 288
  • [33] Frova introducer and double-lumen tubes
    Graham, J.
    Von Heldreich, C.
    Howard, W.
    Fiddes, C.
    ANAESTHESIA, 2013, 68 (07) : 775 - 775
  • [34] Placement of a Double-Lumen Endotracheal Tube
    Hao, David
    Saddawi-Konefka, Daniel
    Baker, Keith
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (27): : 2591 - 2592
  • [35] Placement of VivaSight double-lumen tube
    Levy-Faber, D.
    Malyanker, Y.
    Nir, R. R.
    Best, L. A.
    Barak, M.
    ANAESTHESIA, 2016, 71 (06) : 726 - 727
  • [36] Placement of a Double-Lumen Endotracheal Tube
    Hao, David
    Saddawi-Konefka, Daniel
    Low, Sarah
    Alfille, Paul
    Baker, Keith
    NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (16):
  • [37] EXCHANGING DOUBLE-LUMEN FOR SINGLE-LUMEN ENDOTRACHEAL-TUBES AFTER THORACOTOMY
    RUSCH, VW
    FREUND, PR
    BOWDLE, TA
    ANNALS OF THORACIC SURGERY, 1991, 51 (02): : 323 - 324
  • [38] Placement of double lumen tubes
    Chow, MYH
    Ip-Yam, PC
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (02) : 332 - 332
  • [39] A Randomized Controlled Study of the Use of Video Double-Lumen Endobronchial Tubes Versus Double-Lumen Endobronchial Tubes in Thoracic
    Heir, Jagtar Singh
    Guo, Shu-Lin
    Purugganan, Ronaldo
    Jackson, Tim A.
    Sekhon, Anupamjeet Kaur
    Mirza, Kazim
    Lasala, Javier
    Feng, Lei
    Cata, Juan P.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 267 - 274
  • [40] Double-Lumen Tubes: Which Lumen for the Gum Elastic Bougie?
    Stix, Michael S.
    Ata, Sana
    Wolckenhaar, Marten
    Kaufman, Michael D.
    ANESTHESIA AND ANALGESIA, 2010, 110 (01): : 258 - 258