Validation of a method for the determination of boron in ceramic materials by X-ray fluorescence spectrometry

被引:11
|
作者
Sánchez-Ramos, S [1 ]
Bosch-Reig, F [1 ]
Gimeno-Adelantado, JV [1 ]
Yusá-Marco, DJ [1 ]
Doménech-Carbó, A [1 ]
Berja-Pérez, JA [1 ]
机构
[1] Univ Valencia, Fac Chem, Dept Analyt Chem, E-46100 Valencia, Spain
关键词
boron determination; X-ray fluorescence; ceramics; boracic raw materials; ceramic frits;
D O I
10.1016/S0584-8547(00)00267-6
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method is proposed for boron determination in ceramic materials, boracic raw materials and ceramics frits of different compositions by wavelength dispersive X-ray fluorescence technique. The instrumental conditions were studied and the sample preparation procedures were optimized. The reference method used was the potentiometric titration of mannitol-boric complex acid and the technique was optimized for the determination of B2O3 in each of the materials used. The samples for XRF determination were obtained as pellets and as glass discs. For the pellets different binders were studied, such as mannitol and cellullose for the samples of raw materials, and polyvinylpirrolidone and methyl cellulose (PVP + MC) for the ceramic frits. Samples were obtained in the form of glass discs using lithium tetraborate and a barium-lead glass (BaPbG) as materials to melt, dilute and homogenize the samples, and increase the analytical signal. A series of calibration curves were obtained and the instrumental variables were optimized. The results obtained with the XRF method were compared with the reference method for several unknown samples. The results obtained with both techniques showed relative errors from 0.7 to 3.2% for B2O3 content ranging between 40.8 and 6.3%, respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:1669 / 1677
页数:9
相关论文
共 50 条
  • [21] Method for determination of RE2O3 by X-ray fluorescence spectrometry
    Huang Zhao-min
    Zhou Su-lian
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (09) : 1873 - 1877
  • [22] Method for determination of RE2O3 by X-Ray fluorescence spectrometry
    Huang, Zhao-Min
    Zhou, Su-Lian
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2007, 27 (09): : 1873 - 1877
  • [23] Determination of phosphorus in food samples by X-ray fluorescence spectrometry and standard spectrophotometric method
    Jastrzebska, A
    Brudka, B
    Szymanski, T
    Szlyk, E
    FOOD CHEMISTRY, 2003, 83 (03) : 463 - 467
  • [24] Determination of X-ray excitation spectra in micro X-ray fluorescence spectrometry with capillary optics
    Perez, R. D.
    Sosa, C.
    Sbarato, V.
    Leani, J.
    Sanchez, H. J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 117 : 23 - 28
  • [25] Unified method for the determination of chemical composition in different types of materials using Wavelength Dispersive X-ray Fluorescence Spectrometry
    Smolinski, Adam
    Stempin, Marek
    Howaniec, Natalia
    MEASUREMENT, 2020, 163
  • [26] Determination of Major Elements in Superphosphate by X-Ray Fluorescence Spectrometry
    Rui Yu-kui
    Li He
    Shen Jian-bo
    Mang Fu-suo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (11) : 2703 - 2705
  • [27] Counting Statistics of Uranium Determination by X-Ray Fluorescence Spectrometry
    Qadeer, Riaz
    Khalid, Nasir
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2014, 36 (01): : 44 - 49
  • [28] Experience of the Determination of Fluorine in Rocks by X-Ray Fluorescence Spectrometry
    T. G. Kuz’mina
    T. V. Romashova
    M. A. Troneva
    I. V. Khokhlova
    Journal of Analytical Chemistry, 2023, 78 : 975 - 979
  • [29] Determination of tin in canned foods by X-ray fluorescence spectrometry
    Mino, Y
    JOURNAL OF HEALTH SCIENCE, 2006, 52 (01) : 67 - 72
  • [30] Determination of trace elements in gasoline by X-ray fluorescence spectrometry
    Wang, Qian
    Wang, Qun-Wei
    Zhang, Jian-Bo
    Wang, Song-Qing
    Wu, Bei-Lei
    Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), 2008, 24 (03): : 360 - 364