Intra-peritoneal versus retropubic implantation of three-piece inflatable penile prosthesis: Patient-reported outcomes and complications

被引:2
|
作者
Natali, Alessandro [1 ]
Grisanti Caroassai, Simone [1 ]
Tasso, Giovanni [1 ]
Cito, Gianmartin [1 ]
Gemma, Luca [1 ]
Cocci, Andrea [1 ]
Sessa, Francesco [1 ]
Verrienti, Pierangelo [1 ]
Serni, Sergio [1 ]
Carini, Marco [1 ]
Delle Rose, Augusto [1 ]
机构
[1] Univ Florence, Careggi Hosp, Dept Urol, Largo Brambilla 3, I-50134 Florence, Italy
关键词
Implantation; reservoir; inflatable; penile; prosthesis;
D O I
10.1177/0391560320967876
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The role of reservoir position was investigated in this series of patients treated with three-pieces penile prosthesis implantation (PPI). The outcomes and the patients' reported quality of life after insertion of the balloon in the retropubic space, or the Retzius's space (SOR), were compared with the outcomes of patients who received an intraperitoneal implantation (IP). The study aimed to analyze how the anatomy of the SOR influenced the long-term results of PPI, especially in patients who have been previously exposed to pelvic surgery or radiotherapy. The SOR has usually been identified as ideal for concealing and protecting the reservoir; nevertheless, an increasing rate of patients that ask for a PPI do not conserve the typical favorable characteristic of the SOR. In these cases, the tissue alteration can cause a higher rate of undesired events and can impair the satisfaction from device use. In the recent literature, few articles focus on the topic of reservoir position and very poor information is available about the results of the IP insertion. Materials: Our cohort of patients was retrospectively inspected; the two different subgroups, according to the reservoir position (SOR or IP) were evaluated considering the pre-operative condition, the post-operative complication, the development of undesired events or uncomfortable sensations during the follow-up. The quality of life after PPI was observed as well, with a questionnaire specifically developed for patients treated with PPI. The surgical technique adopted for the intraperitoneal implantation was described. Results: The results of penile prosthesis functionality and patients' and partners' reported quality of life (QoL) showed similar results between the two groups but greater satisfaction in the relational domain of the questionnaires adopted was described in the IP subgroup. Conclusion: According to our observations, the IP reservoir insertion guarantees good functionality and lower rates of undesired events after PPI.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 50 条
  • [31] Prospective Evaluation of Patient Satisfaction, and Surgeon and Patient Trainer Assessment of the Coloplast Titan One Touch Release Three-Piece Inflatable Penile Prosthesis
    Ohl, Dana A.
    Brock, Gerald
    Ralph, David
    Bogache, William
    Jones, LeRoy
    Munarriz, Ricardo
    Levine, Laurence
    Ritenour, Chad
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 (09): : 2467 - 2474
  • [32] THREE-PIECE INFLATABLE PENILE PROSTHESIS REVISION SURGERY LEADS TO INCREASED IMPLANT SIZE INDEPENDENT OF REVISION INDICATION
    Pollard, M.
    Rajanahally, S.
    Sullivan, J.
    Campbell, K.
    Lipshultz, L.
    JOURNAL OF SEXUAL MEDICINE, 2021, 18 (03): : S88 - S88
  • [33] 100 cases of three-piece Inflatable Penile Prosthesis with new scrotal pump: Evaluation of 3 specialised centres
    Garrido-Abad, Pablo
    Rossello-Barbara, Mariano
    Sabino-Galdona, Jose
    Fernandez-Arjona, Manuel
    Rossello-Gaya, Mariano
    ARCHIVOS ESPANOLES DE UROLOGIA, 2015, 68 (04): : 416 - 423
  • [34] Three-piece inflatable penile prosthesis components (surgical pearls on reservoirs, pumps, and rear-tip extenders)
    W J G Hellstrom
    International Journal of Impotence Research, 2003, 15 : S136 - S138
  • [35] Three-piece inflatable penile prosthesis components (surgical pearls on reservoirs, pumps, and rear-tip extenders)
    Hellstrom, WJG
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2003, 15 (Suppl 5) : S136 - S138
  • [36] Pseudo-capsule "coffin effect": How to prevent penile retraction after implant of three-piece inflatable prosthesis
    Caraceni, Enrico
    Utizi, Lilia
    Angelozzi, Giovanni
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2014, 86 (02) : 135 - 137
  • [37] Closed suction drain outputs at 12 and 24 hours after primary three-piece inflatable penile prosthesis surgery
    Apoj, Michel
    Rodriguez, Dayron
    Barbosa, Philip
    Pan, Shu
    Rajender, Archana
    Biebel, Mark
    Gross, Martin
    Munarriz, Ricardo
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2020, 32 (01) : 117 - 121
  • [38] CLOSED SUCTION DRAIN OUTPUTS AT 12 AND 24 HOURS AFTER PRIMARY THREE-PIECE INFLATABLE PENILE PROSTHESIS SURGERY
    Barbosa, P.
    Apoj, M.
    Rodriquez, D.
    Biebel, M.
    Rajender, A.
    Gross, M.
    Munarriz, R.
    JOURNAL OF SEXUAL MEDICINE, 2019, 16 (04): : S117 - S117
  • [39] Closed suction drain outputs at 12 and 24 hours after primary three-piece inflatable penile prosthesis surgery
    Michel Apoj
    Dayron Rodriguez
    Philip Barbosa
    Shu Pan
    Archana Rajender
    Mark Biebel
    Martin Gross
    Ricardo Munarriz
    International Journal of Impotence Research, 2020, 32 : 117 - 121
  • [40] Defining the incidence and management of postoperative scrotal hematoma after primary and complex three-piece inflatable penile prosthesis surgery
    Braun, Avery E.
    Swerdloff, Daniel
    Sudhakar, Architha
    Patel, Rutul D.
    Gross, Martin S.
    Simhan, Jay
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2025, 37 (01) : 82 - 86