Detection of subtle abnormalities on chest radiographs after irreversible compression

被引:42
|
作者
Savcenko, V
Erickson, BJ
Palisson, PM
Persons, KR
Manduca, A
Hartman, TE
Harms, GF
Brown, LR
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Informat Serv, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Biomath Resource, Rochester, MN 55905 USA
关键词
images; storage and retrieval; radiography; technology; thorax;
D O I
10.1148/radiology.206.3.9494474
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the effect of wavelet-based compression of posteroanterior chest radiographs on detection of small uncalcified pulmonary nodules and fibrosis. MATERIALS AND METHODS: Computed tomography (CT) of the chest was used to identify 20 patients with normal posteroanterior chest radiographs, 20 with a solitary uncalcified pulmonary nodule 1-2 cm in diameter, and 20 with fibrotic disease. A double-blind protocol for readings of original images and images compressed at 40:1 and 80:1 was analyzed by using the nonparametric receiver operating characteristic to measure differences in diagnostic accuracy and their statistical significance. RESULTS: There was no substantial differences in the overall diagnostic accuracy (measured by the area under the curve index) for both nodules and fibrosis between images compressed at 40:1 and 80:1 and uncompressed images. Readers tended to perform better on images compressed at 40:1 compared with uncompressed images. The "high-sensitivity" portion of the 80:1 compression curve for nodules was below that for the uncompressed curve, although this was not statistically significant. CONCLUSION: Lossy compression of chest radiographs at 40:1 can be used without decreased diagnostic accuracy for detection of pulmonary nodules and fibrosis. There is no statistically significant difference in diagnostic accuracy at 80:1 compression, but detection ability is decreased.
引用
收藏
页码:609 / 616
页数:8
相关论文
共 50 条
  • [11] Detection of subtle lung nodules: Relative influence of quantum and anatomic noise on chest radiographs
    Samei, E
    Flynn, MJ
    Eyler, WR
    RADIOLOGY, 1999, 213 (03) : 727 - 734
  • [12] Development of a contralateral subtraction technique for detection of subtle lung lesions on digital chest radiographs
    Li, Q
    Ishida, T
    Tsukuda, S
    Katsuragawa, S
    MacMahon, H
    Doi, K
    RADIOLOGY, 1998, 209P : 161 - 162
  • [13] The effect of local background anatomical patterns on the detection of subtle lung nodules in chest radiographs
    Samei, E
    Flynn, MJ
    Eyler, WR
    Peterson, E
    IMAGE PERCEPTION: MEDICAL IMAGING 1998, 1998, 3340 : 44 - 54
  • [14] Irreversible JPEG compression of digital chest radiographs for primary interpretation: Assessment of visually lossless threshold
    Slone, RM
    Muka, E
    Pilgram, TK
    RADIOLOGY, 2003, 228 (02) : 425 - 429
  • [15] WAVELET COMPRESSION OF DIGITIZED CHEST RADIOGRAPHS
    GOLDBERG, MA
    PIVOVAROV, M
    WHITMAN, GJ
    BOLAND, GW
    SHARIF, HS
    RADIOLOGY, 1995, 197 : 537 - 537
  • [16] ENHANCEMENT AND COMPRESSION OF DIGITAL CHEST RADIOGRAPHS
    COHN, M
    TREFLER, M
    YOUNG, TY
    JOURNAL OF THORACIC IMAGING, 1990, 5 (01) : 92 - 95
  • [17] Contralateral subtraction: A novel technique for detection of asymmetric abnormalities on digital chest radiographs
    Li, Q
    Katsuragawa, S
    Ishida, T
    Yoshida, H
    Tsukuda, S
    MacMahon, H
    Doi, K
    MEDICAL PHYSICS, 2000, 27 (01) : 47 - 55
  • [18] NONPULMONARY ABNORMALITIES RECOGNIZABLE IN PEDIATRIC CHEST RADIOGRAPHS
    DUNBAR, JS
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1984, 22 (03) : 723 - 740
  • [19] The Effect of Wavelet and Discrete Cosine Transform Compression of Digital Radiographs on the Detection of Subtle Proximal Caries
    Schulze, R. K. W.
    Richter, A.
    d'Hoedt, B.
    CARIES RESEARCH, 2008, 42 (05) : 334 - 339
  • [20] An approach for chest tube detection in chest radiographs
    Mercan, Cem Ahmet
    Celebi, Mustafa Serdar
    IET IMAGE PROCESSING, 2014, 8 (02) : 122 - 129