Concordance between two rapid diagnostic tests for the detection of antibodies against SARS-CoV-2

被引:5
|
作者
de la Iglesia, Jaime [1 ]
Fernandez-Villa, Tania [2 ]
Fegeneda-Grandes, Juan M. [3 ]
Gomez-Garcia, Manuel [3 ]
Majo Garcia, Raul [4 ]
Lopez Sanz, Silvia [5 ]
Mendez da Cuna, Patricia [6 ]
Llaneza Garcia, Marta [7 ]
Marcos Sadaba, Alicia [8 ]
Fernandez Vazquez, Jose Pedro [9 ]
机构
[1] Ctr Salud Condesa, Med Familiar & Comunitaria, Leon, Spain
[2] Univ Leon, Grp Invest Interacc Gen Ambiente & Salud GIIGAS, Inst Biomed IBIOMED, Leon, Spain
[3] Univ Leon, Fac Vet, Dept Sanidad Anim, Leon, Spain
[4] Gerencia Atenc Primaria Area Salud Leon, Ctr Salud Eras Renueva, Leon, Spain
[5] Gerencia Atenc Primaria Area Salud Leon, Ctr Salud Ribera Esla, Leon, Spain
[6] Ctr Salud La Palomera, Med Familiar & Comunitaria, Leon, Spain
[7] Ctr Salud Trobajo Camino, Med Familiar & Comunitaria, Leon, Spain
[8] Ctr Salud Eras de Renueva, Med Familiar & Comunitaria, Leon, Spain
[9] Gerencia Atenc Primaria Area Salud Leon, Leon, Spain
来源
关键词
SARS-CoV-2; Concordance; Diagnosis; RT-PCR; IgG; IgM;
D O I
10.1016/j.semerg.2020.06.009
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective: To assess the agreement between two rapid detection tests (RDT) for antibodies against SARS-CoV-2 infection. Materials and methods: This was a cross-sectional study that used a random sample of non-hospitalized patients from the primary care management division of the Healthcare Area of Leon (58 RT-PCR-positive cases and 52 RT-PCR-negative cases). Information regarding symptoms was collected and all patients were simultaneously tested using two RDTs (Combined - cRDT and Differentiated - dRDT). The results of both tests were evaluated using the chi-square test and, for degree of agreement, the kappa coefficient. Results: About 52% of the participants were women (mean age: 48.2 +/- 11.0 years). A total of 58.2% were positive for d-RDT and 41.2% were positive for c-RDT. In the subjects who were RT-PCR-positive, d-RDT was positive in 72.4% and c-RDT in 55.2%; in those who were RT-PCR-negative, the percentages were 42.3% and 26.9%, respectively. The kappa coefficient observed between the two RDTs was 0.644, and was higher in patients without a fever or anosmia (0.725) and lower in those with a fever or anosmia (0.524). Conclusions: There is good agreement between the tests used in this study. Given the sensitivity observed, they can be very useful as a complement to RT-PCR. (c) 2020 Sociedad Espanola de Medicos de Atencion Primaria (SEMERGEN). Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [1] Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2
    Tollanes, Mette C.
    Kran, Anne-Marte Bakken
    Abildsnes, Eirik
    Jenum, Pal A.
    Breivik, Anne C.
    Sandberg, Sverre
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (09) : 1595 - 1600
  • [2] Evaluation of 32 rapid tests for detection of antibodies against SARS-CoV-2
    Tollanes, Mette C.
    Jenum, Pal A.
    Kierkegaard, Helene
    Abildsnes, Eirik
    Baevre-Jensen, Roar Magne
    Breivik, Anne C.
    Sandberg, Sverre
    [J]. CLINICA CHIMICA ACTA, 2021, 519 : 133 - 139
  • [3] Evaluation of two immunocromatographic tests for the detection of antibodies against SARS-CoV-2
    Medrano, Sara
    Martinez-Rodriguez, Mercedes
    Vallejo, Luis
    Culebras, Esther
    Delgado-Iribarren, Alberto
    [J]. REVISTA ESPANOLA DE QUIMIOTERAPIA, 2022, 35 (06) : 538 - 543
  • [4] Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
    Guedez-Lopez, Gladys Virginia
    Alguacil-Guillen, Marina
    Gonzalez-Donapetry, Patricia
    Bloise, Ivan
    Tornero-Marin, Carolina
    Gonzalez-Garcia, Juan
    Mingorance, Jesus
    Garcia-Rodriguez, Julio
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (12) : 2289 - 2297
  • [5] Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
    Gladys Virginia Guedez-López
    Marina Alguacil-Guillén
    Patricia González-Donapetry
    Ivan Bloise
    Carolina Tornero-Marin
    Juan González-García
    Jesus Mingorance
    Julio García-Rodríguez
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 2289 - 2297
  • [6] Rapid lateral flow tests for the detection of SARS-CoV-2 neutralizing antibodies
    Wang, Jianfu J.
    Zhang, Nan
    Richardson, Sarah A.
    Wu, Jin V.
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2021, 21 (04) : 363 - 370
  • [7] Serological Tests in the Detection of SARS-CoV-2 Antibodies
    Guevara-Hoyer, Kissy
    Fuentes-Antras, Jesus
    De la Fuente-Munoz, Eduardo
    Rodriguez de la Pena, Antonia
    Vinuela, Marcos
    Cabello-Clotet, Noemi
    Estrada, Vicente
    Culebras, Esther
    Delgado-Iribarren, Alberto
    Martinez-Novillo, Mercedes
    Jose Torrejon, Maria
    Perez de Diego, Rebeca
    Fernandez-Arquero, Miguel
    Ocana, Alberto
    Perez-Segura, Pedro
    Sanchez-Ramon, Silvia
    [J]. DIAGNOSTICS, 2021, 11 (04)
  • [8] Development of Diagnostic Tests for Detection of SARS-CoV-2
    Nguyen, Ngan N. T.
    McCarthy, Colleen
    Lantigua, Darlin
    Camci-Unal, Gulden
    [J]. DIAGNOSTICS, 2020, 10 (11)
  • [9] SARS-CoV-2 rapid antigen detection tests
    Fouzas, Sotirios
    [J]. LANCET INFECTIOUS DISEASES, 2021, 21 (08): : 1068 - 1069
  • [10] Rapid antigen detection tests for SARS-CoV-2
    Liu, Michael
    Arora, Rahul K.
    Krajden, Mel
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (23) : E886 - E887