Evaluation of 32 rapid tests for detection of antibodies against SARS-CoV-2

被引:6
|
作者
Tollanes, Mette C. [1 ,2 ]
Jenum, Pal A. [1 ]
Kierkegaard, Helene [3 ]
Abildsnes, Eirik [4 ]
Baevre-Jensen, Roar Magne [5 ]
Breivik, Anne C. [1 ]
Sandberg, Sverre [1 ,2 ,6 ]
机构
[1] Haraldsplass Deaconess Hosp, Norwegian Org Qual Improvement Lab Examinat, Bergen, Norway
[2] Univ Bergen, Dept Global Publ Hlth & Primary Care, Bergen, Norway
[3] Lillebaelt Hosp, Kolding, Denmark
[4] Kristiansand Municipal, Kristiansand, Norway
[5] Vestre Viken Hosp Trust, Drammen, Norway
[6] Haukeland Hosp, Dept Med Biochem & Pharmacol, Bergen, Norway
关键词
SARS-CoV-2; Rapid tests; Antibody detection; Analytical performance; User-friendliness; Point-of-care; COVID-19; testing; COVID-19 serological testing; LATERAL FLOW IMMUNOASSAYS; RESPONSES; DIAGNOSIS; COVID-19;
D O I
10.1016/j.cca.2021.04.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Aims: To evaluate the analytical performance of 32 rapid tests for detection of antibodies against coronavirus SARS-CoV-2. Materials and methods: We used at total of 262 serum samples (197 pre-pandemic and 65 convalescent COVID19), and three criteria to evaluate the rapid tests under standardized and optimal conditions: (i) Immunoglobulin G (IgG) specificity "good" if lower limit of the 95% confidence interval was > 97.0%, "acceptable" if point estimate was > 97.0%, otherwise "not acceptable". (ii) IgG sensitivity "good" if point estimate was > 90.0%, "acceptable" if > 85.0%, otherwise "not acceptable". (iii) User-friendliness "not acceptable" if complicated to perform or difficult to read result, otherwise "good". We also included partial evaluations of three automated immunoassay systems. Results: Sensitivity and specificity varied considerably; IgG specificity between 90.9% (85.9-94.2) and 100% (97.7-100.0), and IgG sensitivity between 53.8% (41.9-65.4) and 98.5% (91.0-100.0). Combining our evaluation criteria, none of the 28 rapid tests that detected IgG had an overall performance considered "good", seven tests were considered "acceptable", while 21 tests were considered "not acceptable". Four tests detected only total antibodies and were not given an overall evaluation. IgG sensitivity and/or specificity of the automated immunoassays did not exceed that of many rapid tests. Conclusion: When prevalence is low, the most important analytical property is a test's IgG specificity, which must be high to minimize false positive results. Out of 32 rapid tests, none had a performance classified as "good", but seven were classified as "acceptable".
引用
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [1] Evaluation of eleven rapid tests for detection of antibodies against SARS-CoV-2
    Tollanes, Mette C.
    Kran, Anne-Marte Bakken
    Abildsnes, Eirik
    Jenum, Pal A.
    Breivik, Anne C.
    Sandberg, Sverre
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (09) : 1595 - 1600
  • [2] Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
    Guedez-Lopez, Gladys Virginia
    Alguacil-Guillen, Marina
    Gonzalez-Donapetry, Patricia
    Bloise, Ivan
    Tornero-Marin, Carolina
    Gonzalez-Garcia, Juan
    Mingorance, Jesus
    Garcia-Rodriguez, Julio
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2020, 39 (12) : 2289 - 2297
  • [3] Evaluation of three immunochromatographic tests for rapid detection of antibodies against SARS-CoV-2
    Gladys Virginia Guedez-López
    Marina Alguacil-Guillén
    Patricia González-Donapetry
    Ivan Bloise
    Carolina Tornero-Marin
    Juan González-García
    Jesus Mingorance
    Julio García-Rodríguez
    [J]. European Journal of Clinical Microbiology & Infectious Diseases, 2020, 39 : 2289 - 2297
  • [4] Evaluation of two immunocromatographic tests for the detection of antibodies against SARS-CoV-2
    Medrano, Sara
    Martinez-Rodriguez, Mercedes
    Vallejo, Luis
    Culebras, Esther
    Delgado-Iribarren, Alberto
    [J]. REVISTA ESPANOLA DE QUIMIOTERAPIA, 2022, 35 (06) : 538 - 543
  • [5] Concordance between two rapid diagnostic tests for the detection of antibodies against SARS-CoV-2
    de la Iglesia, Jaime
    Fernandez-Villa, Tania
    Fegeneda-Grandes, Juan M.
    Gomez-Garcia, Manuel
    Majo Garcia, Raul
    Lopez Sanz, Silvia
    Mendez da Cuna, Patricia
    Llaneza Garcia, Marta
    Marcos Sadaba, Alicia
    Fernandez Vazquez, Jose Pedro
    [J]. MEDICINA DE FAMILIA-SEMERGEN, 2020, 46 : 28 - 32
  • [6] Rapid lateral flow tests for the detection of SARS-CoV-2 neutralizing antibodies
    Wang, Jianfu J.
    Zhang, Nan
    Richardson, Sarah A.
    Wu, Jin V.
    [J]. EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2021, 21 (04) : 363 - 370
  • [7] Evaluation of nine serological rapid tests for the detection of SARS-CoV-2
    Mercado, Marcela
    Malagon-Rojas, Jeadran
    Delgado, Gabriela
    Vanesa Rubio, Vivian
    Munoz Galindo, Lida
    Parra Barrera, Eliana L.
    Gaviria, Paula
    Zabaleta, Gabriela
    Alarcon, Zonia
    Arevalo, Adriana
    Casallas Cifuentes, Helly
    Estrada, Kelly
    Puerto, Gloria
    Herrera Sepulveda, Maria T.
    Rodriguez, Helena
    Galindo, Marisol
    Ospina Ramirez, Martha Lucia
    [J]. REVISTA PANAMERICANA DE SALUD PUBLICA-PAN AMERICAN JOURNAL OF PUBLIC HEALTH, 2020, 44
  • [8] Serological Tests in the Detection of SARS-CoV-2 Antibodies
    Guevara-Hoyer, Kissy
    Fuentes-Antras, Jesus
    De la Fuente-Munoz, Eduardo
    Rodriguez de la Pena, Antonia
    Vinuela, Marcos
    Cabello-Clotet, Noemi
    Estrada, Vicente
    Culebras, Esther
    Delgado-Iribarren, Alberto
    Martinez-Novillo, Mercedes
    Jose Torrejon, Maria
    Perez de Diego, Rebeca
    Fernandez-Arquero, Miguel
    Ocana, Alberto
    Perez-Segura, Pedro
    Sanchez-Ramon, Silvia
    [J]. DIAGNOSTICS, 2021, 11 (04)
  • [9] SARS-CoV-2 rapid antigen detection tests
    Fouzas, Sotirios
    [J]. LANCET INFECTIOUS DISEASES, 2021, 21 (08): : 1068 - 1069
  • [10] Rapid antigen detection tests for SARS-CoV-2
    Liu, Michael
    Arora, Rahul K.
    Krajden, Mel
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2021, 193 (23) : E886 - E887