Sensitivity reduction mechanisms in organic perovskite X-ray detectors

被引:3
|
作者
Hoq, Afazul [1 ]
Panneerselvam, Dhilippan M. [1 ]
Kabir, M. Z. [1 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, 1455 Blvd Maisonneuve West, Montreal, PQ H3G 1M8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HYBRID PEROVSKITES; A-SE; PHOTOCONDUCTORS;
D O I
10.1007/s10854-021-06240-7
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The sensitivity reduction mechanisms in organic perovskite X-ray detectors are investigated in this paper by considering the dynamics of charge carrier transport across the perovskite photoconductor. A numerical model is proposed by considering bimolecular recombination, space charge effects, charge carrier trapping (monomolecular) and detrapping. The coupled continuity equations for both holes and electrons, trapping rate equations, and Poisson's equation across the photoconductor are simultaneously solved by a finite difference method. The numerical results are compared with COMSOL simulation. The change of sensitivity is not significant for a usual single exposure in diagnostic medical X-ray imaging applications. However, the sensitivity starts decreasing rapidly for an order of magnitude higher dose rate or accumulated dose under repeated exposures. The rapid change of electric field distribution (i.e., non-uniform electric field) is mainly responsible for the reduction of X-ray sensitivity in perovskite X-ray detectors.
引用
下载
收藏
页码:16824 / 16830
页数:7
相关论文
共 50 条
  • [21] Flexible perovskite scintillators and detectors for X-ray detection
    Wang, Baiqian
    Yang, Xin
    Chen, Shi
    Lu, Shirong
    Zhao, Shuangyi
    Qian, Qingkai
    Cai, Wensi
    Wang, Shenghao
    Zang, Zhigang
    ISCIENCE, 2022, 25 (12)
  • [22] Perovskite: Scintillators, direct detectors, and X-ray imagers
    Jana, Atanu
    Cho, Sangeun
    Patil, Supriya A.
    Meena, Abhishek
    Jo, Yongcheol
    Sree, Vijaya Gopalan
    Park, Youngsin
    Kim, Hyungsang
    Im, Hyunsik
    Taylor, Robert A.
    MATERIALS TODAY, 2022, 55 : 110 - 136
  • [23] X-ray Detectors Based on Halide Perovskite Materials
    Tan, Yimei
    Mu, Ge
    Chen, Menglu
    Tang, Xin
    COATINGS, 2023, 13 (01)
  • [24] Reduction of the Output Ripple in X-Ray Detectors
    V. F. Dvoryankin
    Yu. M. Dikaev
    A. A. Kudryashov
    A. G. Petrov
    Instruments and Experimental Techniques, 2002, 45 : 295 - 296
  • [25] Reduction of the output ripple in X-ray detectors
    Dvoryankin, VF
    Dikaev, YM
    Kudryashov, AA
    Petrov, AG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2002, 45 (02) : 295 - 296
  • [26] Reduction of the output ripple in X-ray detectors
    Dvoryankin, V.F.
    Dikaev, Yu.M.
    Kudryashov, A.A.
    Petrov, A.G.
    Pribory i Tekhnika Eksperimenta, 2002, 45 (02): : 159 - 161
  • [27] A Study on Improving the Sensitivity of Indirect X-ray Detectors by Adding Hybrid Perovskite Quantum Dots
    Lee, Kwanyong
    Lee, Jehoon
    Han, Daeho
    Liu, Hailiang
    Kang, Jungwon
    COATINGS, 2022, 12 (04)
  • [28] Dependence of x-ray sensitivity of direct conversion x-ray detectors on x-ray exposure and exposure history
    Kabir, MZ
    Yunus, M
    Kasap, SO
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 170 - 176
  • [29] Improved sensitivity X-ray detectors for field applications
    Redus, R
    Pantazis, J
    Huber, A
    Pantazis, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (06) : 3247 - 3253
  • [30] Improved sensitivity X-ray detectors for field applications
    Redus, R
    Pantazis, J
    Huber, A
    Pantazis, T
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 986 - 990