Application of 3-D lumped parameter model in MHD generator design

被引:1
|
作者
Geri, A
Veca, GM
Salvini, A
机构
[1] Univ Roma La Sapienza, Dipartimento Ingn Elettr, I-00184 Rome, Italy
[2] Univ Roma Tre, Dipartimento Ingn Elettr, I-00146 Rome, Italy
关键词
circuit model; energy conversion; generator; inverter; magnetic field computation; MHD; SC magnets;
D O I
10.1109/60.849120
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Magnetohydrodynamic (MHD) energy conversion consists of electrical energy generation directly from high enthalpy of ionized gas. MHD generators are devices having a channel in which ionized gas (plasma) is blown, where a high magnetic field is present, The interaction between the conductive gas and the magnetic field makes the conversion. To describe and to design the MHD plants, circuital models of MHD generators are advantageous for an easier investigation approach to the interface between generators and power plants; they become extremely useful when a 3-D analysis is necessary for easier computation taking into account 3-D effects due to spatial distribution of electromagnetic fields. In this paper we describe some design applications of the three-dimensional (3-D) lumped parameter model for MHD generators.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [31] 3-D SPH simulations of HD and MHD jets
    DalPino, EMD
    Cerqueira, AH
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1996, 34 (1-6) : 303 - 308
  • [32] 3-D relativistic mhd simulations of extragalactic jets
    Nishikawa, KI
    Frank, J
    Christodoulou, DM
    Koide, S
    Sakai, JI
    Sol, H
    Mutel, RL
    NUMERICAL ASTROPHYSICS, 1999, 240 : 217 - 218
  • [33] Investigations of MHD wave coupling in a 3-D numerical model: effects of temperature gradients
    Lee, DH
    Lysak, RL
    Song, Y
    STREAMERS, SLOW SOLAR WIND, AND THE DYNAMICS OF THE MAGNETOSPHERE, 2004, 33 (05): : 742 - 746
  • [34] Stabilization in 3-D FEM and solution of the MHD equations
    Aydin, S. H.
    Erdogan, M. C.
    MATHEMATICAL METHODS IN THE APPLIED SCIENCES, 2023, 46 (12) : 13395 - 13410
  • [35] Asymptotic stability of equilibrium to 3-D MHD system
    Deng, Wen
    Zhang, Ping
    MATHEMATICAL ANALYSIS IN FLUID MECHANICS: SELECTED RECENT RESULTS, 2018, 710 : 85 - 103
  • [36] Validation and verification of a robust 3-D MHD code
    Gajbhiye, Narendra Laxman
    Throvagunta, Praveen
    Eswaran, Vinayak
    FUSION ENGINEERING AND DESIGN, 2018, 128 : 7 - 22
  • [37] VLSI implementation of 3-D sound generator
    Suen, AN
    Wang, JF
    Wang, JC
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1997, 43 (03) : 679 - 688
  • [38] VLSI implementation of 3-D sound generator
    Suen, AN
    Wang, JF
    Wang, JC
    INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS, 1997 DIGEST OF TECHNICAL PAPERS, 1997, : 296 - 297
  • [39] LUMPED PARAMETER THERMAL-MODEL FOR ELECTRICAL MACHINES OF TEFC DESIGN
    MELLOR, PH
    ROBERTS, D
    TURNER, DR
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1991, 138 (05): : 205 - 218
  • [40] The design of a lumped parameter model considering the stimulus path of round window
    Kim, Jong Hoon
    Park, Min Gyu
    Wei, Qun
    Seong, Ki Woong
    Lee, Jyung Hyun
    TECHNOLOGY AND HEALTH CARE, 2021, 29 : S49 - S56