Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial

被引:30
|
作者
Kuramitsu, Shoichi [1 ]
Kazuno, Yoshio [1 ]
Sonoda, Shinjo [2 ]
Domei, Takenori [1 ]
Jinnouchi, Hiroyuki [1 ]
Yamaji, Kyohei [1 ]
Soga, Yoshimitsu [1 ]
Shirai, Shinichi [1 ]
Ando, Kenji [1 ]
Saito, Shigeru [3 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Kokurakita Ku, 3-2-1 Asano, Kitakyushu, Fukuoka 8028555, Japan
[2] Univ Occupat & Environm Hlth Japan, Sch Med, Dept Internal Med 2, Kitakyushu, Fukuoka, Japan
[3] Shonan Kamakura Gen Hosp, Cardiol & Catheterizat Labs, Kamakura, Kanagawa, Japan
关键词
Bioresorbable polymer; Sirolimus-eluting stent; Optical coherence tomography; Coronary artery disease; DURABLE-POLYMER; THROMBOSIS; COVERAGE; RISK;
D O I
10.1093/ehjci/jev203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomography (OCT). Methods and results A total of 36 patients participated in the CENTURY II trial in our institution and were randomly assigned to BP-SES (n = 15) and PP-EES (n = 21). Of these, 27 patients (13 BP-SES and 14 PP-EES) underwent OCT at 9-month follow-up. Tissue coverage and apposition were assessed on each strut, and the results in both groups were compared using multilevel logistic or linear regression models with randomeffects at three levels: patient, lesion, and struts. A total of 6450 struts (BP-SES, n = 2951; PP-EES, n = 3499) were analysed. Thirty and 79 uncovered struts (1.02 and 2.26%, P = 0.35), and 3 and 4 malapposed struts (0.10 and 0.11%, P = 0.94) were found in BP-SES and PP-EES groups, respectively. Mean neointimal thickness did not significantly differ between both groups (110 +/- 10 vs. 93 +/- 10 mu m, P = 0.22). No significant differences in per cent neointimal volume obstruction (13.2 +/- 4.6 vs. 10.5 +/- 4.9%, P = 0.14) or other areas-volumetric parameters were detected between both groups. Conclusion BP-SES shows an excellent vascular healing response at 9-month follow-up, which is similar to PP-EES.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [1] Long-Term Vascular Response to Permanent Polymer Everolimus-Eluting Stent vs. Biodegradable Polymer Biolimus-Eluting Stent: Five-year Follow-up Optical Coherence Tomography Study
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Jinnouchi, Hiroyuki
    Muraoka, Yoshitaka
    Domei, Takenori
    Shirai, Shinichi
    Ando, Kenji
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B226 - B226
  • [2] Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent Sequential Optical Coherence Tomography Study
    Ogura, Kunihiro
    Tsujita, Hiroaki
    Oishi, Yosuke
    Matsumoto, Hidenari
    Matsukawa, Naoki
    Sakai, Rikuo
    Arai, Taito
    Sato, Shunya
    Tanaka, Hideaki
    Masaki, Ryota
    Arai, Ken
    Nomura, Kosuke
    Kosaki, Ryota
    Sakai, Koshiro
    Sekimoto, Teruo
    Kondo, Seita
    Tsukamoto, Shigeto
    Mori, Hiroyoshi
    Yamamoto, Myong Hwa
    Wakabayashi, Kohei
    Suzuki, Hiroshi
    Ochiai, Masahiko
    Shinke, Toshiro
    INTERNATIONAL HEART JOURNAL, 2021, 62 (03) : 510 - 519
  • [3] Comparison of Sirolimus Eluting Stent With Bioresorbable Polymer to Everolimus Eluting Stent With Permanent Polymer in Bifurcation Lesions: Results From CENTURY II Trial
    Orvin, K.
    Carrie, D.
    Richardt, G.
    Desmet, W.
    Assali, A.
    Werner, G.
    Ikari, Y.
    Fujii, K.
    Goicolea, J.
    Dangoisse, V.
    Manari, A.
    Saito, S.
    Wijns, W.
    Kornowski, R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (06) : 1092 - 1100
  • [4] Early vascular healing following bioresorbable-polymer sirolimus-eluting stent implantation in comparison with durable-polymer everolimus-eluting stent: sequential optical coherence tomography study
    Ogura, K.
    Tsujita, H.
    Arai, T.
    Sakai, R.
    Tanaka, H.
    Masaki, R.
    Oishi, Y.
    Nomura, K.
    Arai, K.
    Sekimoto, T.
    Kondo, S.
    Tsukamoto, S.
    Mori, H.
    Matsumoto, H.
    Shinke, T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1391 - 1391
  • [5] Angiographic outcomes of everolimus-eluting stent as compared to sirolimus-eluting stent: a sub-study of the RESET trial
    Foin, N.
    Sen, S.
    Di Mario, C.
    Davies, J. E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 834 - 835
  • [6] Bioresorbable polymer sirolimus-eluting coronary stent compared with permanent polymer everolimus-eluting coronary stent implantation for treatment of small vessel coronary artery disease: CENTURY II trial
    Woehrle, Jochen
    Markovic, Sinisa
    Rottbauer, Wolfgang
    Muramatsu, Toshiya
    Kadota, Kazushige
    Vazquez-Gonzalez, Nicolas
    Odenstedt, Jacob
    Serra, Antonio
    Antoniucci, David
    Varenne, Olivier
    Saito, Shigeru
    Wijns, William
    EUROINTERVENTION, 2016, 12 (02) : E167 - E174
  • [7] LONG-TERM VASCULAR RESPONSE TO PERMANENT POLYMER EVEROLIMUS-ELUTING STENT COMPARED WITH BIODEGRADABLE POLYMER BIOLIMUS-ELUTING STENT: FIVE-YEAR FOLLOW-UP OPTICAL COHERENCE TOMOGRAPHY STUDY
    Kuramitsu, Shoichi
    Sonoda, Shinjo
    Jinnouchi, Hiroyuki
    Muraoka, Yoshitaka
    Domei, Takenori
    Hyodo, Makoto
    Shirai, Shinichi
    Ando, Kenji
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1049 - 1049
  • [8] FAVORABLE NEOINTIMAL COVERAGE IN EVEROLIMUS-ELUTING STENT AT 9 MONTH AFTER STENT IMPLANTATION: COMPARISON WITH SIROLIMUS-ELUTING STENT USING OPTICAL COHERENCE TOMOGRAPHY
    Choi, Hyun-Hee
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Hong, Myeong-Ki
    Jang, Yangsoo
    Sim, Won-Heum
    Cho, Seung-Yun
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [9] Angiographic findings of everolimus-eluting as compared to sirolimus-eluting stents: Angiographic sub-study from the Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial (RESET)
    Kozuma K.
    Kimura T.
    Kadota K.
    Suwa S.
    Kimura K.
    Iwabuchi M.
    Kawai K.
    Miyazawa A.
    Kawamura M.
    Nakao K.
    Asano R.
    Yamamoto T.
    Suzuki N.
    Aoki J.
    Kyono H.
    Nakazawa G.
    Tanabe K.
    Morino Y.
    Igarashi K.
    Cardiovascular Intervention and Therapeutics, 2013, 28 (4) : 344 - 351
  • [10] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent Results of the Randomized BIOFLOW-II Trial
    Windecker, Stephan
    Haude, Michael
    Neumann, Franz-Josef
    Stangl, Karl
    Witzenbichler, Bernhard
    Slagboom, Ton
    Sabate, Manel
    Goicolea, Javier
    Barragan, Paul
    Cook, Stephane
    Piot, Christophe
    Richardt, Gert
    Merkely, Bela
    Schneider, Henrik
    Bilger, Johannes
    Erne, Paul
    Waksman, Ron
    Zaugg, Serge
    Jueni, Peter
    Lefevre, Thierry
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02)