Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth

被引:16
|
作者
Clark, Paul A.
Clark, Andrew M.
Rodriguez, Anthony
Hussain, Mohammad A.
Mao, Jeremy J.
机构
[1] Univ Illinois, Dept Anat & Cell Biol, Tissue Engn Lab MC 841, Chicago, IL 60612 USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL 60612 USA
[3] Univ Illinois, Dept Orthodont, Chicago, IL 60612 USA
基金
美国国家卫生研究院;
关键词
atomic force microscope; osteoblast; implants; bone; nanoindentation;
D O I
10.1016/j.msec.2006.05.056
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bone-implant interface is characterized by an array of cells and macromolecules. This study investigated the nanomechancial properties of bone-implant interface using atomic force microscopy in vitro, and the mechanical modulation of implant bone ingrowth in vivo using bone histomorphometry. Upon harvest of screw-type titanium implants placed in vivo in the rabbit maxilla and proximal femur for 4 weeks, nanoindentation was performed in the bone-implant interface at 60-mu m intervals radially from the implant surface. The average Young's Moduli (E) of the maxillary bone-implant interface was 1.13 +/- 0.27 MPa, lacking significant differences at all intervals. In contrast, an increasing gradient of E was observed radially from the femur bone-implant interface: 0.87 +/- 0.25 MPa to 2.24 +/- 0.69 MPa, representing significant differences among several 60-mu m intervals. In a separate experiment, bone healing was allowed for 6 weeks for proximal femur implants. The right femoral implant received axial cyclic loading at 200 mN and I Hz for 10 min/d over 12 days, whereas the left femoral implant served as control. Cyclic loading induced significantly higher bone volume, osteoblast numbers per endocortical bone surface, mineral apposition rate, and bone formation rate than controls. These data demonstrate nanoscale and microscale characterizations of bone-implant interface, and mechanical modulation of bone ingrowth surrounding titanium implants. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:382 / 393
页数:12
相关论文
共 50 条
  • [21] Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio
    Raffa, Maria Letizia
    Nguyen, Vu-Hieu
    Hernigou, Philippe
    Flouzat-Lachaniette, Charles-Henri
    Haiat, Guillaume
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (06) : 1174 - 1183
  • [22] Osseointegration and current interpretations of the bone-implant interface
    Shah, Furqan A.
    Thomsen, Peter
    Palmquist, Anders
    ACTA BIOMATERIALIA, 2019, 84 : 1 - 15
  • [23] STATIC AND DYNAMIC TESTING OF BONE-IMPLANT INTERFACE
    KOLBEL, R
    BERGMANN, G
    ROHLMANN, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (02): : 281 - 281
  • [24] MOLECULAR-STRUCTURE AT THE BONE-IMPLANT INTERFACE - A VIBRATIONAL SPECTROSCOPIC CHARACTERIZATION
    WALTERS, MA
    BLUMENTHAL, NC
    LEUNG, Y
    WANG, Y
    RICCI, JL
    SPIVAK, JM
    CALCIFIED TISSUE INTERNATIONAL, 1991, 48 (05) : 368 - 369
  • [25] Molecular analysis of healing at a bone-implant interface
    Colnot, C.
    Romero, D. M.
    Huang, S.
    Rahman, J.
    Currey, J. A.
    Nanci, A.
    Brunski, J. B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2007, 86 (09) : 862 - 867
  • [26] Minimum contact fraction of bone-implant interface
    Jang, KS
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 837 - 837
  • [27] Multimodal characterization of the bone-implant interface using Raman spectroscopy and nanoindentation
    Fraulob, Manon
    Pang, Siyuan
    Le Cann, Sophie
    Vayron, Romain
    Laurent-Brocq, Mathilde
    Todatry, Soorya
    Soares, Julio A. N. T.
    Jasiuk, Iwona
    Haiat, Guillaume
    MEDICAL ENGINEERING & PHYSICS, 2020, 84 : 60 - 67
  • [28] Optical bone chambers as tools for studying the bone-implant interface: A review
    Winet, H
    CELLS AND MATERIALS, 1995, 5 (03): : 293 - 308
  • [29] Effect of different impactor designs on biomechanical behavior in the interface bone-implant: A comparative biomechanics study
    Bachiri, Abdessamed
    Djebbar, Noureddine
    Boutabout, Benali
    Serier, Boualem
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 197
  • [30] Study with speckle interferometry of bone-implant interface conditions
    Simoes, J
    Monteiro, J
    Vaz, M
    Taylor, M
    Blatcher, S
    EXPERIMENTAL MECHANICS, VOLS 1 AND 2: ADVANCES IN DESIGN, TESTING AND ANALYSIS, 1998, : 851 - 855