Characterization of a high-density downer reactor

被引:26
|
作者
Chen, HZ [1 ]
Li, HZ [1 ]
机构
[1] Chinese Acad Sci, Inst Proc Engn, Multiphase React Lab, Beijing 100080, Peoples R China
基金
中国国家自然科学基金;
关键词
high-density downer; solids flux; transient solids concentration; solids concentration distribution;
D O I
10.1016/j.powtec.2004.07.008
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments were carried out in a specially designed circulating fluidized bed with a 5.6-m tall, 0.08 m ID downer, in which the maximal the solids flux 600 kg m(-2) s(-1) and the maximal solids holdup 0.14 have been achieved. The results show that single peak exists in the PDD curves of the solids concentration for low-density operation, and a higher platform is present in the PDD curves for the high-density downer. Solids flux is a key factor that affects the solids holdup while particle properties are other important parameter. The heavier/better fluidity particle could achieve the structure still exists in the high-density downer, but radial solids distribution gradually becomes more uniform with downward distance and with the increase of solids flux. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 92
页数:9
相关论文
共 50 条
  • [21] High-density culture of hairy roots with a radial flow reactor
    Setsuji, T
    Masahiro, KO
    Yoshio, H
    Masahito, T
    4TH INTERNATIONAL CONFERENCE ON BIOREACTOR & BIOPROCESS FLUID DYNAMICS, 1997, (25): : 115 - 125
  • [22] FURTHER CHARACTERIZATION OF BOVINE HIGH-DENSITY LIPOPROTEINS
    FERRERI, LF
    GLEOCKLER, DH
    JOURNAL OF DAIRY SCIENCE, 1979, 62 : 190 - 191
  • [23] CHARACTERIZATION OF HIGH-DENSITY POLYETHYLENE BY RHEOLOGICAL MEASUREMENTS
    FLEISSNER, M
    ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1981, 94 (MAR): : 197 - 210
  • [24] The characterization of high-density polyethylene/organoclay nanocomposites
    Tathiane Cordeiro Rodrigues
    Maria Inês Bruno Tavares
    Igor Lopes Soares
    Ana M. Moreira
    JOM, 2009, 61
  • [25] CHARACTERIZATION OF HIGH-DENSITY LIPOPROTEIN IN ALCOHOLIC HEPATITIS
    GREEN, PHR
    QUINET, E
    TALL, AR
    GLICKMAN, RM
    CLINICAL RESEARCH, 1980, 28 (02): : A483 - A483
  • [26] The Characterization of High-Density Polyethylene/Organoclay Nanocomposites
    Rodrigues, Tathiane Cordeiro
    Bruno Tavares, Maria Ines
    Soares, Igor Lopes
    Moreira, Ana M.
    JOM, 2009, 61 (01) : 38 - 41
  • [27] CHARACTERIZATION OF POLYIMIDES USED IN HIGH-DENSITY INTERCONNECTS
    PECHT, M
    WU, X
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART B-ADVANCED PACKAGING, 1994, 17 (04): : 632 - 639
  • [28] CHARACTERIZATION OF HIGH-DENSITY LIPOPROTEINS IN HUMAN CHOLESTASIS
    ARNESJO, B
    DANIELSSON, B
    EKMAN, R
    JOHANSSON, BG
    PETERSSON, BG
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 (07): : 587 - 597
  • [29] 3D CPFD simulation of gas-solids flow in the high-density downer with FCC particles
    Wu, Yingya
    Shi, Xiaogang
    Liu, Yancong
    Wang, Chengxiu
    Gao, Jinsen
    Lan, Xingying
    POWDER TECHNOLOGY, 2020, 373 : 384 - 396
  • [30] Characterization of a novel high-density lipoprotein antioxidant capacity assay and its application to high-density lipoprotein fractions
    Gaal, Krisztina
    Lorincz, Hajnalka
    Seres, Ildiko
    Harangi, Mariann
    Olah, Anna V.
    Paragh, Gyoergy
    CLINICAL BIOCHEMISTRY, 2013, 46 (09) : 825 - 827