Efficacy of innovative polyglycolic acid sheet device delivery station system: a randomized prospective study
被引:9
|作者:
Mori, Hirohito
[1
,3
]
Guan, Yu
[2
]
Kobara, Hideki
[1
]
Kobayashi, Seiki
[3
]
Nishiyama, Noriko
[1
]
Kobayashi, Nobuya
[1
]
Masaki, Tsutomu
[1
]
机构:
[1] Kagawa Univ, Fac Med, Dept Gastroenterol & Neurol, Kita Ku, 1750-1 Ikenobe, Miki, Kagawa 7610793, Japan
[2] Kagawa Univ, Dept Pharmacol, Kita Ku, 1750-1 Ikenobe, Miki, Kagawa 7610793, Japan
[3] Ehime Rosai Hosp, Dept Gastroenterol Surg, 13-27 Minamikomatsubara, Niihama, Ehime 7928550, Japan
来源:
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES
|
2018年
/
32卷
/
07期
关键词:
Delivery of polyglycolic acid sheet;
Coating area per minute;
Post-endoscopic submucosal dissection bleeding;
Device delivery station system;
ENDOSCOPIC SUBMUCOSAL DISSECTION;
PREVENT ESOPHAGEAL STRICTURE;
TISSUE SHIELDING METHOD;
FIBRIN GLUE;
DELAYED PERFORATION;
STEROID INJECTION;
GASTRIC NEOPLASMS;
RISK-FACTORS;
CANCER;
ULCER;
D O I:
10.1007/s00464-017-6019-6
中图分类号:
R61 [外科手术学];
学科分类号:
摘要:
Although there have been several reports of treating large post-endoscopic submucosal dissection (ESD) ulcers by covering them with a polyglycolic acid sheet (PGAs), this approach presents problems regarding PGAs delivery. This study assessed the usefulness of a device delivery station system (DDSS) to evaluate the appropriate and rapid PGAs coating method with DDSS. Thirty-nine of 41 patients who were diagnosed with early gastric cancer over 20 mm in diameter and pathologically diagnosed with well-differentiated adenocarcinoma were randomly allocated to the following two groups according to delivery method: the conventional PGAs delivery group (C group) (n = 19) and the new DDSS group (DDSS group) (n = 20). The primary outcome was the coating area per minute in the C group and DDSS group (cm(2)/min). There were significant differences in the coating time (min), with values of 34.1 (15.0-60.7) vs. 16.85 (11.5-27.2) min for the C group and DDSS group, respectively (p = 0.001). There was also a significant difference in coating area per minute, with values of 0.261 (0.02-1.00) and 0.96 (0.173-2.06) cm(2)/min for the C group and DDSS group, respectively (p = 0.001). There were four cases of post-ESD bleeding (1-7 days after ESD) in the C group compared with 0 in the DDSS group, which represented a significant difference (p = 0.030). The DDSS was very useful for rapidly delivering and tightly attaching a PGAs to control post-ESD bleeding. University Hospital Medical Network (UMIN) 000026377.