Evaluation of the BIOMIC video reader system for routine use in the clinical microbiology laboratory

被引:8
|
作者
Geiss, HK [1 ]
Klar, UE [1 ]
机构
[1] Univ Heidelberg, Inst Hyg, D-69120 Heidelberg, Germany
关键词
D O I
10.1016/S0732-8893(00)00132-2
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The BIOMIC Video Reader System (Giles Scientific, New York, NY, USA) is a semi-automated AST method that combines disk diffusion testing with automated reading and data interpretation. We evaluated this system with 497 strains comprising a total of 5821 drug organism combinations (DOC) from our routine diagnostic laboratory. Additionally, we compared the time required of the manual and the automated method. The overall agreement of interpretative categories of all DOC was 96.1%. However, comparing complete tests the agreement was only 70.8%. The average time required of the BIOMIC system to complete a test was more than twice as long as that of the manual method. Our data suggest that the tested version of the BIOMIC system cannot be recommended for routine use in diagnostic laboratories. (C) 2000 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 50 条
  • [21] Detection of extended-spectrum β-lactamases in a Singapore routine clinical microbiology laboratory
    Chiew, YF
    JOURNAL OF HOSPITAL INFECTION, 2004, 56 (04) : 328 - 329
  • [22] Machine learning in the clinical microbiology laboratory: has the time come for routine practice?
    Peiffer-Smadja, N.
    Delliere, S.
    Rodriguez, C.
    Birgand, G.
    Lescure, F-X
    Fourati, S.
    Ruppe, E.
    CLINICAL MICROBIOLOGY AND INFECTION, 2020, 26 (10) : 1300 - 1309
  • [23] EVALUATION OF THE RAL SMEARBOX FOR ROUTINE USE IN LABORATORY
    Roze, Jocelyn
    Mohamed-Osman, Aziza
    Girard, Sandrine
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 150 - 150
  • [24] MODEL OF COMPUTERIZED SYSTEM FOR MANAGEMENT OF CLINICAL MICROBIOLOGY LABORATORY
    SCHITO, GC
    BERTOLINI, L
    ANNALI SCLAVO, 1976, 18 (06): : 907 - 908
  • [25] ELECTRONIC DATA PROCESSING SYSTEM FOR CLINICAL MICROBIOLOGY LABORATORY
    AMSTERDAM, D
    SCHNEIERSON, SS
    APPLIED MICROBIOLOGY, 1969, 17 (01) : 93 - +
  • [26] SYSTEM OF INTERPRETATION OF INFRARED-SPECTRA OF CALCULI FOR ROUTINE USE IN CLINICAL LABORATORY
    OLIVER, LK
    SWEET, RV
    CLINICA CHIMICA ACTA, 1976, 72 (01) : 17 - 32
  • [27] Evaluation of Erytra® Analyzer and DG Gel® System for Routine Use in Transfusion Laboratory
    Brown, M.
    Davies, L.
    Brown, R. E.
    Pointon, L.
    Chung, C.
    Barker, D.
    TRANSFUSION, 2011, 51 : 176A - 176A
  • [28] Effective use of the clinical microbiology laboratory for diagnosing diarrheal diseases
    Hines, J
    Nachamkin, I
    CLINICAL INFECTIOUS DISEASES, 1996, 23 (06) : 1292 - 1301
  • [29] Evaluation of Invader® HCV genotyping ASRs in a clinical microbiology laboratory
    Finberg, K. E.
    Eversley, J. S.
    Rosenberg, E. S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 645 - 645
  • [30] Evaluation of the BD Phoenix Automated Identification and Susceptibility Testing System in Clinical Microbiology Laboratory Practice
    E. Stefaniuk
    A. Baraniak
    M. Gniadkowski
    W. Hryniewicz
    European Journal of Clinical Microbiology and Infectious Diseases , 2003, 22 : 479 - 485