Detailed energy integration study of the front-end of an existing ammonia plant has been performed, using recent advances in Pinch technology. Utility loads demanded by the existing process were found to be very close to the calculated minimum targets. This indicated that the selected ammonia plant is well integrated, and not much saving is expected through process-to-process energy integration. Alternatively, the retrofit study concentrated on better placement of available utilities. Two promising options have been investigated. The first one studied the flue gas temperature in the convection section of the primary reformer, and proposed new arrangements of the heating coils. Boiler feed water heating for high-pressure steam generation has been also considered as a possible source for reduction in energy consumption. Total benefit claimed amounted to 17.6% reduction in combustion fuel consumption. The overall results of this case study are promising, However, economical evaluation of the proposed modifications is essential. Additional possible reduction in energy consumption is also possible in energy and power integration of the back-end section. (C) 2000 Elsevier Science Ltd, All rights reserved.
引用
收藏
页码:1495 / 1503
页数:9
相关论文
共 50 条
  • [21] Testing and study of oil burner retrofit in Zhongshan A Power Plant
    Liu, Xue-Xun
    Jiang, Xiao
    Zheng, Zhi-Guang
    Xu, Tao
    Ma, Qi-Liang
    Zhongguo Dianli/Electric Power, 2002, 35 (11):
  • [22] An alternative procedure to retrofit an industrial plant. A case study
    Liporace, FS
    Pessoa, FLP
    Queiroz, EM
    LATIN AMERICAN APPLIED RESEARCH, 2002, 32 (02) : 161 - 170
  • [23] ENERGY RETROFIT OF HISTORICAL BUILDINGS: AN ITALIAN CASE STUDY
    Aste, N.
    Adhikari, R. S.
    Buzzetti, M.
    JOURNAL OF GREEN BUILDING, 2012, 7 (04): : 144 - 165
  • [24] Central plant retrofit considerations
    Haviland, JR
    SOLUTIONS FOR ENERGY SECURITY AND FACILITY MANAGEMENT CHALLENGES, 2003, : 37 - 41
  • [26] Efficiency improvements for the coal-fired power plant retrofit with CO2 capture plant using chilled ammonia process
    Hanak, Dawid P.
    Biliyok, Chechet
    Manovic, Vasilije
    APPLIED ENERGY, 2015, 151 : 258 - 272
  • [27] "Green" Ammonia: Impact of Renewable Energy Intermittency on Plant Sizing and Levelized Cost of Ammonia
    Nayak-Luke, Richard
    Banares-Alcantara, Rene
    Wilkinson, Ian
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (43) : 14607 - 14616
  • [28] Process intensification for the retrofit of a multicomponent distillation plant - An industrial case study
    Errico, Massimiliano
    Rong, Ben-Guang
    Tola, Giuseppe
    Turunen, Ilkka
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (06) : 1975 - 1980
  • [29] Energy retrofit of commercial buildings: case study and applied methodology
    Aste, Niccolo
    Del Pero, Claudio
    ENERGY EFFICIENCY, 2013, 6 (02) : 407 - 423
  • [30] Heat Exchanger Network Retrofit of an Oleochemical Plant through a Cost and Energy Efficiency Approach
    Trisha, Valli
    Koh, Kai Seng
    Ng, Lik Yin
    Chok, Vui Soon
    CHEMENGINEERING, 2021, 5 (02)