Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils

被引:1
|
作者
Masaryk, AM
Frayne, R
Unal, O
Rappe, AH
Strother, CM
机构
[1] Univ Arizona, Ctr Hlth Sci, Dept Radiol, Tucson, AZ 85724 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
[4] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[5] Univ Calgary, Dept Radiol, Calgary, AB, Canada
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts, We investigated the ability of time-resolved contrast-enhanced SD MR angiography (3D MR digital subtraction angiography [DSA]) to accurately depict the anatomy of experimental lateral aneurysms before and after treatment with GDCs and a variety of stents or stent-grafts, and compared these findings with 3D-TOF MR angiography without and with contrast enhancement and CT angiography. METHODS: Two nitinol stents, two nitinol-polytetrafluoroethylene (PTFE) stent-grafts, and two stainless steel stents were deployed in three dogs with experimental carotid aneurysms, In a fourth animal, one of three aneurysms was completely occluded with GDCs, The other two aneurysms were loosely packed to ensure persistence of some residual aneurysmal lumen. Cut-film angiography, CT angiography, 3D-TOF MR angiography without and with contrast enhancement, and 3D MR DSA were performed in all dogs before and 3 weeks after treatment. RESULTS: SD MR DSA was superior to conventional SD-TOF MR angiography without and with contrast enhancement in accurately depicting experimental lateral aneurysms and superior to CT angiography in depicting aneurysms treated by GDCs, SD MR DSA and CT angiography were comparable in depicting vessels treated with nitinol stents and stent-grafts, whereas CT angiography was superior for showing vessels treated by stainless steel stents. CONCLUSION: We recommend further development and clinical evaluation of 3D MR DSA For imaging cerebral aneurysms before and after treatment with GDCs, 3D MR DSA or CT angiography may be useful for evaluating vessels containing nitinol stents or nitinol-PTFE stent-grafts, whereas CT angiography should be used for follow-up of vessels treated by stainless steel stents.
引用
收藏
页码:1523 / 1531
页数:9
相关论文
共 50 条
  • [41] Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography
    W. Weber
    T. Yousry
    S. Felber
    H. Henkes
    H. Nahser
    N. Roer
    D. Kühne
    European Radiology, 2001, 11 : 1792 - 1797
  • [42] Noninvasive follow-up of GDC-treated saccular aneurysms by MR angiography
    Weber, W
    Yousry, TA
    Felber, SR
    Henkes, H
    Nahser, HC
    Roer, N
    Kühne, D
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1792 - 1797
  • [43] Angiographic follow-up of vertebrobasilar artery aneurysms treated with detachable coils
    C. Groden
    B. Eckert
    T. Ries
    E. Neumaier Probst
    T. Kucinski
    H. Zeumer
    Neuroradiology, 2003, 45 : 435 - 440
  • [44] Angiographic follow-up of vertebrobasilar artery aneurysms treated with detachable coils
    Groden, C
    Eckert, B
    Ries, T
    Probst, EN
    Kucinski, T
    Zeumer, H
    NEURORADIOLOGY, 2003, 45 (07) : 435 - 440
  • [45] Angiographical follow-up results of cerebral aneurysms treated by Guglielmi detachable coil system
    Hyogo, T
    Kataoka, T
    Hayase, K
    Nakamura, H
    INTERVENTIONAL NEURORADIOLOGY, 2001, 7 : 137 - 142
  • [46] Long-term Follow-up Angiography of Intracranial Aneurysms Treated with Cook Detachable Coil System
    Pardo, M. I.
    Pumar, J. M.
    Abal, D.
    Garcia-Allut, A.
    Blanco, M.
    Vazquez, F.
    NEURORADIOLOGY JOURNAL, 2008, 21 (05): : 712 - 716
  • [47] Time-of-flight MR angiography at 3T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils
    Ferre, Jean-Christophe
    Carsin-Nicol, Beatrice
    Morandi, Xavier
    Carsin, Michel
    de Kersaint-Gilly, Axel
    Gauvrit, Jean-Yves
    Desal, Hubert-Armand
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 365 - 369
  • [48] Cerebral aneurysms treated by Guglielmi detachable coils: Evaluation with diffusion-weighted MR imaging
    Biondi, A
    Oppenheim, C
    Vivas, E
    Casasco, A
    Lalam, T
    Sourour, N
    Le Jean, L
    Dormont, D
    Marsault, C
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (05) : 957 - 963
  • [49] MR angiography follow-up of embolized cerebral aneurysms: interobserver agreement
    Diaz Aguilera, R.
    Bravo Rodriguez, F.
    Ramos Gomez, M. J.
    Cano Sanchez, A.
    Martinez Paredes, M.
    Delgado Acosta, F.
    RADIOLOGIA, 2009, 51 (03): : 300 - 306
  • [50] MR Angiographic Follow-Up of Intracranial Aneurysms Treated with Detachable Coils: Evaluation of a Blood-Pool Contrast Medium
    Kau, T.
    Gasser, J.
    Celedin, S.
    Rabitsch, E.
    Eicher, W.
    Uhl, E.
    Hausegger, K. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) : 1524 - 1530