Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils

被引:1
|
作者
Masaryk, AM
Frayne, R
Unal, O
Rappe, AH
Strother, CM
机构
[1] Univ Arizona, Ctr Hlth Sci, Dept Radiol, Tucson, AZ 85724 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Phys Med, Madison, WI 53706 USA
[4] Univ Calgary, Dept Clin Neurosci, Calgary, AB, Canada
[5] Univ Calgary, Dept Radiol, Calgary, AB, Canada
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Previous studies have depicted arterial and aneurysmal anatomy with three-dimensional time-of-flight (3D-TOF) MR angiography before and after treatment with Guglielmi detachable coils (GDCs) and with CT angiography before and after treatment with stents and stent-grafts, We investigated the ability of time-resolved contrast-enhanced SD MR angiography (3D MR digital subtraction angiography [DSA]) to accurately depict the anatomy of experimental lateral aneurysms before and after treatment with GDCs and a variety of stents or stent-grafts, and compared these findings with 3D-TOF MR angiography without and with contrast enhancement and CT angiography. METHODS: Two nitinol stents, two nitinol-polytetrafluoroethylene (PTFE) stent-grafts, and two stainless steel stents were deployed in three dogs with experimental carotid aneurysms, In a fourth animal, one of three aneurysms was completely occluded with GDCs, The other two aneurysms were loosely packed to ensure persistence of some residual aneurysmal lumen. Cut-film angiography, CT angiography, 3D-TOF MR angiography without and with contrast enhancement, and 3D MR DSA were performed in all dogs before and 3 weeks after treatment. RESULTS: SD MR DSA was superior to conventional SD-TOF MR angiography without and with contrast enhancement in accurately depicting experimental lateral aneurysms and superior to CT angiography in depicting aneurysms treated by GDCs, SD MR DSA and CT angiography were comparable in depicting vessels treated with nitinol stents and stent-grafts, whereas CT angiography was superior for showing vessels treated by stainless steel stents. CONCLUSION: We recommend further development and clinical evaluation of 3D MR DSA For imaging cerebral aneurysms before and after treatment with GDCs, 3D MR DSA or CT angiography may be useful for evaluating vessels containing nitinol stents or nitinol-PTFE stent-grafts, whereas CT angiography should be used for follow-up of vessels treated by stainless steel stents.
引用
收藏
页码:1523 / 1531
页数:9
相关论文
共 50 条
  • [1] Follow-up angiography of intracranial aneurysms treated with endovascular placement of Guglielmi detachable coils
    Thornton, J
    Debrun, GM
    Aletich, VA
    Bashir, Q
    Charbel, FT
    Ausman, J
    NEUROSURGERY, 2002, 50 (02) : 239 - 249
  • [2] Intracranial aneurysms treated with Guglielmi detachable coils - Imaging follow-up with contrast-enhanced MR Angiography
    Gauvrit, JY
    Leclerc, X
    Caron, S
    Taschner, CA
    Lejeune, JP
    Pruvo, JP
    STROKE, 2006, 37 (04) : 1033 - 1037
  • [3] MR angiography in the follow-up of coiled cerebral aneurysms after treatment with Guglielmi detachable coils
    Nome, T
    Bakke, SJ
    Nakstad, PH
    ACTA RADIOLOGICA, 2002, 43 (01) : 10 - 14
  • [4] Follow-up angiography of intracranial aneurysms treated with endovascular placement of Guglielmi detachable coils -: Comments
    Albuquerque, FC
    McDougall, CG
    Spetzler, RF
    Solomon, RA
    Viñuela, F
    Ringer, AJ
    Hopkins, LN
    NEUROSURGERY, 2002, 50 (02) : 249 - 250
  • [5] MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis
    Kwee, Thomas C.
    Kwee, Robert M.
    NEURORADIOLOGY, 2007, 49 (09) : 703 - 713
  • [6] Aneurysms of the anterior communicating artery treated with Guglielmi detachable coils: Follow-up with contrast-enhanced MR angiography
    Leclerc, X
    Navez, JF
    Gauvrit, JY
    Lejeune, JP
    Pruvo, JP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1121 - 1127
  • [7] MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis
    Thomas C. Kwee
    Robert M. Kwee
    Neuroradiology, 2007, 49 : 703 - 713
  • [8] Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils
    Brunereau, L
    Cottier, JP
    Sonier, CB
    Medioni, B
    Bertrand, P
    Rouleau, P
    Sirinelli, D
    Herbreteau, D
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 216 - 223
  • [9] Meta-analysis on Diagnostic Accuracy of MR Angiography in the Follow-Up of Residual Intracranial Aneurysms Treated with Guglielmi Detachable Coils
    Weng, Hsu-Huei
    Jao, Shaner-Yeun
    Yang, Chun-Yuh
    Tsai, Yuan-Hsiung
    INTERVENTIONAL NEURORADIOLOGY, 2008, 14 : 53 - 63
  • [10] MR-angiography evaluation of intracranial aneurysms treated with Guglielmi detachable coils
    Aprile, I
    Lavaroni, A
    Petralia, B
    Biasizzo, E
    Fabris, G
    RIVISTA DI NEURORADIOLOGIA, 2001, 14 (04): : 407 - 414