摘要
This review provides a concise survey of liquid chromatography tandem mass spectrometry (LCTMS) as an emerging technology in clinical chemistry. The combination of two mass spectrometers with an interposed collision cell characterizes LCTMS as an analytical technology on its own and not just as a more specific detector for HPLC compared with conventional techniques. In LCTMS, liquid chromatography is rather used for sample preparation but not for complete resolution of compounds of interest. The instrument technology of LCTMS is complex and comparatively expensive; however, in routine use, methods are far more rugged compared to conventional chromatographic techniques and enable highthroughput analyses with very limited manual handling steps. Moreover, compared to both gas chromatographymass spectrometry (GCMS) and conventional HPLC techniques, LCTMS is substantially more versatile with respect to the spectrum of analyzable compounds. For these reasons it is likely that LCTMS will gain far more widespread use in the clinical laboratory than HPLC and GCMS ever did. In this article, the key features of LCTMS are described, method development is explained, typical fields of application are discussed, and personal experiences are related.
引用
收藏
页码:117 / 126
页数:10
相关论文
共 50 条
  • [1] The role of liquid chromatography-tandem mass spectrometry in the clinical laboratory
    van den Ouweland, Johannes M. W.
    Kema, Ido P.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 : 18 - 32
  • [2] Liquid chromatography-tandem mass spectrometry in the clinical laboratory: Now and into the future
    Taylor, P. J.
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 896 - 896
  • [3] Liquid chromatography-tandem mass spectrometry in clinical laboratory protein measurement
    Ma, Yichen
    Wang, Danchen
    Li, Honglei
    Ma, Xiaoli
    Zou, Yutong
    Mu, Danni
    Yu, Songlin
    Cheng, Xinqi
    Qiu, Ling
    [J]. CLINICA CHIMICA ACTA, 2024, 562
  • [4] Pitfalls Associated with the Use of Liquid Chromatography-Tandem Mass Spectrometry in the Clinical Laboratory
    Vogeser, Michael
    Seger, Christoph
    [J]. CLINICAL CHEMISTRY, 2010, 56 (08) : 1234 - 1244
  • [5] Liquid chromatography-tandem mass spectrometry for clinical diagnostics
    不详
    [J]. NATURE REVIEWS METHODS PRIMERS, 2022, 2 (01):
  • [6] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [7] Liquid chromatography tandem mass spectrometry in the clinical laboratory
    Adaway, Joanne E.
    Keevil, Brian G.
    Owen, Laura J.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (01) : 18 - 38
  • [8] Liquid Chromatography-Tandem Mass Spectrometry An Emerging Technology in the Toxicology Laboratory
    Zhang, Yan Victoria
    Wei, Bin
    Zhu, Yu
    Zhang, Yanhua
    Bluth, Martin H.
    [J]. CLINICS IN LABORATORY MEDICINE, 2016, 36 (04) : 635 - +
  • [9] Determination of zolpidem in human plasma by liquid chromatography-tandem mass spectrometry for clinical application
    Byeon, Ji-Yeong
    Lee, Hye-In
    Lee, Yun-Jeong
    Lee, Jung-Eun
    Kim, Se-Hyung
    Kim, Young-Hoon
    Na, Han-Sung
    Jang, Choon-Gon
    Lee, Seok-Yong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 986 : 129 - 134
  • [10] Application of liquid chromatography-tandem mass spectrometry to the analysis of benzodiazepines in blood
    Rivera, HM
    Walker, GS
    Sims, DN
    Stockham, PC
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2003, 9 (06) : 599 - 607