Magnet alignment monitoring system with eigenfrequency-based wire sag correction

被引:7
|
作者
Zhang, C. [1 ]
Azumi, N. [1 ]
Fukami, K. [1 ,2 ]
Kimura, H. [1 ,4 ]
Kiuchi, J. [3 ]
Matsui, S. [2 ]
Takemura, Y. [3 ]
Takano, S. [1 ,2 ]
Watanabe, T. [1 ,2 ]
机构
[1] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
[2] RIKEN SPring 8 Ctr, Mikazuki, Hyogo 6795148, Japan
[3] SPring 8 Serv Co Ltd, Kamigori, Hyogo 6795165, Japan
[4] Natl Inst Quantum & Radiol Sci & Technol, Inst Adv Synchrotron Light Source, Mikazuki, Hyogo 6795148, Japan
关键词
stretched wire; magnet alignment; wire sag; eigenfrequency; capacitive sensor;
D O I
10.1088/1361-6501/abe5e4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The precision of magnet alignment in next-generation light sources is critical. To achieve this, the multipole magnets on a common girder of SPring-8-II, an upgrade of SPring-8, are planned to be aligned using the vibrating-wire technique. We developed an alignment monitoring system to monitor the magnet positions in the tunnel where the vibrating-wire technique cannot be executed while the magnets are not energized or when there are vacuum chambers in the magnet center. The alignment monitoring system utilizes a non-contact capacitive sensor embedded in a ceramic ball to measure the wire position relative to the center of the ball and derives the wire sag by measuring a higher mode eigenfrequency. The constitution of this system is illustrated for relevant studies, including the investigation of wire sag against the eigenfrequency, observation of the actual wire sag at a test bench, and validation of the system on the girders for the prototype magnets of SPring-8-II. The system measured the positions of a series of magnets with a precision of +/- 4 mu m (peak to peak) in a 4 m range, in both the horizontal and vertical directions, meeting the requirement of SPring-8-II.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Wire bonding monitoring system based on LabVIEW for three-level inverter IGBT modules
    Sun, Zhiyu
    Ma, Mingyao
    Chu, Kaiqi
    Wang, Ye
    Zhang, Xing
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (07): : 165 - 172
  • [22] Design of automation devices clips status monitoring system based on 1WIRE bus
    Zheng, Min
    Luo, Yuan-An
    Zhao, Guang-Hui
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (06): : 73 - 76
  • [23] A new convergence monitoring system for tunnel or drift based on draw-wire displacement sensors
    Li, Yuan-hui
    Xu, Shi-da
    Liu, Jian-po
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2015, 49 : 92 - 97
  • [24] Erratum to: “Precise out-vacuum proton beam monitoring system based on vibrating wire”
    M. A. Aginian
    S. G. Arutunian
    D. Choe
    M. Chung
    G. S. Harutyunyan
    S. -Y. Kim
    E. G. Lazareva
    A. V. Margaryan
    Journal of Contemporary Physics (Armenian Academy of Sciences), 2017, 52 : 303 - 303
  • [25] Modeling of a Wavelet-Based Voltage Sag Monitoring System and Design for the Mixed-Signal Integrated Circuit Implementation
    Yang, Wen-Ren
    O'Connell, Robert
    Wang, Chau-Shing
    Chen, Liang-Rui
    2008 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-5, 2008, : 36 - +
  • [26] Millimeter Wave Based Real-Time Sag Measurement and Monitoring System of Overhead Transmission Lines in a Smart Grid
    Mahin, Ayman Uddin
    Hossain, Md. Farhad
    Islam, Shama Naz
    Munasinghe, Kumudu S.
    Jamalipour, Abbas
    IEEE ACCESS, 2020, 8 : 100754 - 100767
  • [27] Action Characteristic Monitoring System for Permanent Magnet Vacuum Circuit Breaker Based on CAN Communication Technology
    Lang Fu-cheng
    Tai Xiao-xue
    Zhao Hao-rong
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 491 - 494
  • [28] Development of a room laser based real-time alignment monitoring system using an array of photodiodes
    Noh, Yu-Yun
    Kim, Tae-Ho
    Kang, Seong-Hee
    Kim, Dong-Su
    Cho, Min-Seok
    Kim, Kyeong-Hyeon
    Shin, Dong-Seok
    Yoon, Do-Kun
    Kim, Siyong
    Suh, Tae Suk
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (10): : 1284 - 1291
  • [29] A precise method of monitoring the alignment of two-mirror telescopes, based on a system of synthesized annular holograms
    Baloev, V. A.
    Ivanov, V. P.
    Larionov, N. P.
    Lukin, A. V.
    Mel'nikov, A. N.
    Skochilov, A. F.
    Uraskin, A. M.
    Chugunov, Yu. P.
    JOURNAL OF OPTICAL TECHNOLOGY, 2012, 79 (03) : 167 - 173
  • [30] Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes
    Noh, Y.
    Kim, S.
    Kim, T.
    Kang, S.
    Kim, D.
    Cho, M.
    Kim, K.
    Shin, D.
    Suh, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3416 - 3416