Energy reshaping based passive fractional-order PID control design and implementation of a grid-connected PV inverter for MPPT using grouped grey wolf optimizer

被引:58
|
作者
Yang, Bo [1 ]
Yu, Tao [2 ,3 ]
Shu, Hongchun [1 ]
Zhu, Dena [1 ]
An, Na [1 ]
Sang, Yiyan [4 ]
Jiang, Lin [4 ]
机构
[1] Kunming Univ Sci & Technol, Fac Elect Power Engn, Kunming 650500, Yunnan, Peoples R China
[2] South China Univ Technol, Coll Elect Power, Guangzhou 510640, Guangdong, Peoples R China
[3] Guangdong Key Lab Clean Energy Technol, Guangzhou 510640, Guangdong, Peoples R China
[4] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
基金
中国国家自然科学基金;
关键词
Photovoltaic inverter; MPPT; Passivity; Fractional-order PID control; Energy reshaping; POWER POINT TRACKING; SLIDING-MODE CONTROL; WIND TURBINE; PHOTOVOLTAIC INVERTER; PREDICTIVE CONTROL; VSC-HVDC; SYSTEM; SIMULATION; ALGORITHM; EXTRACTION;
D O I
10.1016/j.solener.2018.05.034
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper designs a novel passive fractional-order proportional-integral-derivative (PFoPID) controller for a grid-connected photovoltaic (PV) inverter via energy reshaping, such that the maximum power point tracking (MPPT) can be achieved through perturb and observe (P&O) technique under different atmospheric conditions. Based on the passivity theory, a storage function associated with the DC-link voltage and DC-link current, as well as q-axis current is firstly constructed for the PV system, in which the physical property (e.g., heat produced on resistors) of each term is thoroughly investigated and analyzed while the beneficial terms are carefully retained in order to fully exploit the essential characteristics of the PV system. Then, the remaining energy of the storage function is reshaped via an additional input in the context of fractional-order PID (FoPID) control framework, which control parameters are optimally tuned by grouped grey wolf optimizer (GGWO), such that an optimal control performance can be realized. Four case studies, including the solar irradiation variation, temperature variation, power grid voltage drop, and PV inverter parameter uncertainties, are carried out. Simulation results verify the effectiveness and advantages of PEoPID control in comparison to that of conventional PID control, fractional-order PID (FoPID) control, and passivity-based control (PBC), respectively. Lastly, a dSpace based hardware-in-loop (HIL) experiment is undertaken to validate the implementation feasibility of the proposed approach.
引用
收藏
页码:31 / 46
页数:16
相关论文
共 50 条
  • [21] An Admittance Reshaping Strategy of Three-Phase LCL Grid-Connected Inverter Based on Modified Passive Control
    Wang H.
    Zhang J.
    Shi G.
    Zhu M.
    Cai X.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2023, 57 (09): : 1105 - 1113
  • [22] Adaptive Fractional Order PID Controller Based MPPT for PV Connected Grid System Under Changing Weather Conditions
    Ali Nasir
    Imran Rasool
    Daud Sibtain
    Raheel Kamran
    Journal of Electrical Engineering & Technology, 2021, 16 : 2599 - 2610
  • [23] Adaptive Fractional Order PID Controller Based MPPT for PV Connected Grid System Under Changing Weather Conditions
    Nasir, Ali
    Rasool, Imran
    Sibtain, Daud
    Kamran, Raheel
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (05) : 2599 - 2610
  • [24] Study on Control of Single Phase Grid-Connected Inverter Based on Fractional Order PI Controller
    Jiang, Ping
    Lv, Hai-Jian
    Wang, Li-ying
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, MACHINERY AND ENERGY ENGINEERING (MSMEE 2017), 2017, 123 : 1414 - 1420
  • [25] Fractional Order PID Design for a Proton Exchange Membrane Fuel Cell System Using an Extended Grey Wolf Optimizer
    Yousri Silaa, Mohammed
    Barambones, Oscar
    Derbeli, Mohamed
    Napole, Cristian
    Bencherif, Aissa
    PROCESSES, 2022, 10 (03)
  • [26] MPPT Techniques Applied to the Control of a Module-Integrated Inverter Grid-Connected Based on Zeta Converter for PV Panels
    Pedrollo, Guilherme R.
    dos Reis, Fernando B.
    de Faria, Paulo Fernando S. R.
    Viero, Renan C.
    Levin, Gustavo H.
    de Lima, Julio Cesar M.
    dos Reis, Fernando S.
    2012 10TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2012,
  • [27] Fractional-Order Control of Grid-Connected Photovoltaic System Based on Synergetic and Sliding Mode Controllers
    Nicola, Marcel
    Nicola, Claudiu-Ionel
    ENERGIES, 2021, 14 (02)
  • [28] Adaptability enhancement of fractional-order LLCL-type grid-connected inverter to weak grid based on grid voltage weighted feedforward scheme
    Wang, Xiaogang
    Zhuang, Ruidong
    Yang, Ru
    Hu, Wei
    Zou, Tao
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (06) : 2597 - 2621
  • [29] Enhancing Grid-Connected DFIG's LVRT Capability Using Dandelion Optimizer Based the Hybrid Fractional-Order PI and PI Controlled STATCOM
    Fouad, Abdallah
    Kotb, Hossam
    Aboras, Kareem M.
    Elrefaie, Hesham B.
    Alqarni, Mohammed
    Baqasah, Abdullah M.
    Yakout, Ahmed H.
    IEEE ACCESS, 2024, 12 : 120181 - 120197
  • [30] Improved Fractional-Order Sliding-Mode Voltage Controller-Based MPDPC Strategy for PV Grid-Connected
    Zhang, Xiaoying
    You, Zixuan
    Qian, Lingzhi