Performance evaluation of a portable 3D imaging system

被引:3
|
作者
Givi, Mehrdad [1 ]
Cournoyer, Luc [1 ]
Reain, Greg [1 ]
Eves, Brian J. [1 ]
机构
[1] Natl Res Council Canada, NRC Metrol, Ottawa, ON K1A 0R6, Canada
关键词
Portable 3D imaging systems; Sphere-to-sphere distance measurement error; Uncertainty budget; CAPABILITY;
D O I
10.1016/j.precisioneng.2019.06.002
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
y Portable 3D imaging systems are important tools used by industry for metrology, inspection, and reverse engineering. The Creaform HandySCAN 300 is a portable 3D imaging system that utilizes photogrammetry to orientate a handheld scanner relative to the part under test. The system does not have a well-defined coordinate system or a fixed measurement range and there currently exists a lack of nonnative standards suitable for evaluating the performance of such a system. We use the determination of sphere-to-sphere distances and the related measurement uncertainty as a proxy for evaluating the systems performance. The error sources of the imaging system were quantified and an improved measurement process that minimized errors was developed. A comparison between measurements by the HandySCAN 300 and a coordinate measuring machine showed good agreement with normalized errors of less than one.
引用
收藏
页码:156 / 165
页数:10
相关论文
共 50 条
  • [31] Toward Development of a Portable System for 3D Fluorescence Lymphography
    Dixon, Alexander W.
    Richardson, Samuel P.
    Suami, Hiroo
    Gamage, Thiranja P. Babarenda
    Nielsen, Poul M. F.
    Reynolds, Hayley M.
    [J]. 2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [32] Portable 3D Scanning System Based on an Inertial Sensor
    Tang, Qijian
    Peng, Xiang
    Liu, Xiaoli
    Cai, Zewei
    [J]. INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONICS ENGINEERING (ICOPEN 2016), 2017, 10250
  • [33] Portable laser scanning system for 3D contour measure
    Zhu, Jigui
    Wang, Hao
    Ren, Tongqun
    Wu, Bin
    Liu, Changjie
    [J]. Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2005, 41 (02): : 166 - 169
  • [34] A Portable Electromagnetic Head Imaging System Using Metamaterial Loaded Compact Directional 3D Antenna
    Islam, Mohammad Shahidul
    Islam, Mohammad Tariqul
    Hoque, Ahasanul
    Islam, Md Tarikul
    Amin, Nowshad
    Chowdhury, Muhammad E. H.
    [J]. IEEE ACCESS, 2021, 9 (09): : 50893 - 50906
  • [35] A portable modular system for automatic acquisition of 3D objects
    Ferrari, S
    Borghese, NA
    [J]. IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 1823 - 1827
  • [36] The analysis of the structural parameter influences on measurement errors in a binocular 3D reconstruction system: a portable 3D system
    Sha, Ou
    Zhang, Hongyu
    Bai, Jing
    Zhang, Yaoyu
    Yang, Jianbai
    [J]. PEERJ COMPUTER SCIENCE, 2023, 9
  • [37] The analysis of the structural parameter influences on measurement errors in a binocular 3D reconstruction system: a portable 3D system
    Sha, Ou
    Zhang, Hongyu
    Bai, Jing
    Zhang, Yaoyu
    Yang, Jianbai
    [J]. PeerJ Computer Science, 2023, 9 : 1 - 24
  • [38] Improved 3D Imaging Performance of MPC
    Rana, M. S.
    Pota, H. R.
    Petersen, I. R.
    [J]. 2015 54TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2015, : 7359 - 7364
  • [39] Robotic 3D SQUID imaging system for practical nondestructive evaluation applications
    Isawa, K
    Nakayama, S
    Ikeda, M
    Takagi, S
    Tosaka, S
    Kasai, N
    [J]. PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2005, 432 (3-4): : 182 - 192
  • [40] Evaluation of a novel digital 3D imaging system for assessing wound volume
    Dini, Valentina
    Romanelli, Marco
    Barbanera, Sabrina
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2012, 66 (04) : AB217 - AB217