Hip Rotator Strength in Healthy Young Adults Measured in Hip Flexion and Extension by Using a Hand-held Dynamometer

被引:13
|
作者
Bloom, Nancy [1 ]
Cornbleet, Suzanne L. [1 ]
机构
[1] Washington Univ, Sch Med, Program Phys Therapy, St Louis, MO 63130 USA
关键词
TORQUES; MUSCLES;
D O I
10.1016/j.pmrj.2014.06.002
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To investigate the effect of hip joint position on hip rotator muscle strength of healthy young adults by using a hand-held dynamometer. Design: A cross-sectional cohort study. Setting: A university medical center. Participants: Thirty-four healthy (19 women, 15 men; mean [standard deviation] age, 25 +/- 2.3 years) participated in this study. Methods: A hand-held dynamometer was used to measure the strength of hip internal rotators and external rotators in 2 positions: hip flexion in sitting and hip extension in supine. The hip was tested in a neutral position with respect to rotation, abduction, and adduction. Isometric force in pounds was measured as the subject pushed against the device. Main Outcome Measurements: For each subject, hip rotator muscle strength measurements were taken during a single session. Hypotheses were developed before data collection. Results: Hip internal rotators were significantly stronger in hip flexion compared with hip extension (P < .01). There was no significant difference found in the hip external rotators between the 2 positions. Conclusions: Hip internal rotators and external rotators behave differently when comparing strength measurements between the positions of hip flexion and hip extension. A hand-held dynamometer provided an objective measurement of strength that was clinically feasible to use. Both muscle length and moment arms influence force production of the hip rotators as the hip position changes. Understanding these relationships may help clinicians interpret strength findings and direct intervention toward strengthening the appropriate muscles by using the most advantageous position.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 50 条
  • [1] Hip extension strength measured using hand-held dynamometry in a rehabilitation setting
    Cardin, Grace
    Bohannon, Richard W.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2017, 25 (02) : 157 - 160
  • [2] Clinical assessment of hip strength using a hand-held dynamometer is reliable
    Thorborg, K.
    Petersen, J.
    Magnusson, S. P.
    Holmich, P.
    [J]. SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2010, 20 (03) : 493 - 501
  • [3] Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer
    Ieiri, Akira
    Tushima, Eiki
    Ishida, Kazuhiro
    Inoue, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (02) : 146 - 152
  • [4] INTERTESTER RELIABILITY OF THE HAND-HELD DYNAMOMETER FOR WRIST FLEXION AND EXTENSION
    RHEAULT, W
    BEAL, JL
    KUBIK, KR
    NOWAK, TA
    SHEPLEY, JA
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1989, 70 (13): : 907 - 910
  • [5] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [6] Inter- and Intratester Reliability of Strength Measurement of Knee Extension and Flexion with a Modified Hand-Held Dynamometer in Healthy Subjects
    Schaefer, A.
    Dressel, M.
    Kaemmerer, S.
    Peschke, L.
    Braun, M. Ramos
    Schoettker-Koeniger, T.
    [J]. MANUELLE THERAPIE, 2015, 19 (01) : 38 - 44
  • [7] Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer
    Schache, Margaret B.
    McClelland, Jodie A.
    Webster, Kate E.
    [J]. DISABILITY AND REHABILITATION, 2016, 38 (06) : 597 - 600
  • [8] Reliability of the Hand-Held Dynamometer During Hip Isometric Strength Testing Both With and Without a Stabilization Strap
    Beard, Megan Q.
    Boland, Samantha A.
    Gribble, Phillip A.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (01): : 37 - 42
  • [9] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    [J]. JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2023,
  • [10] Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
    Florencio, Lidiane L.
    Martins, Jaqueline
    da Silva, Marcelo R. B.
    da Silva, Janaina R.
    Bellizzi, Gustavo L.
    Bevilaqua-Grossi, Debora
    [J]. PHYSICAL THERAPY IN SPORT, 2019, 38 : 115 - 122