HOW MUCH DO I GIVE? REEVALUATION OF INSULIN DOSING ESTIMATION FORMULAS USING CONTINUOUS GLUCOSE MONITORING

被引:17
|
作者
King, Allen B. [1 ]
机构
[1] Diabet Care Ctr, Salinas, CA USA
关键词
D O I
10.4158/EP09308.OR
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To reevaluate current formulas for determining the total basal insulin dosage (TBD), insulin to carbohydrate ratio (ICR), and correction factor (CF) from weight or total daily dosage (TDD) in pump-treated patients with type 1 diabetes mellitus. Methods: From a post hoc analysis of data from 4 previously published studies, subjects who met the inclusion criteria were selected. No subject was duplicated. For all studies, the basal glucose target was to have fewer than 20% of glucose readings greater than 170 mg/dL and to have 10% or fewer glucose readings less than 70 mg/dL. Bolus insulin was adjusted to achieve a 2- to 4-hour postbolus glucose value within 20% of the premeal glucose (ICR) or 80 to 120 mg/dL from premeal hyperglycemia (CF). In the first 2 studies, dosing titration by CGM was performed from 72-hour CGM tracings every week to every 6 weeks. In the other 2 studies, 24- to 72-hour CGM downloads and insulin adjustments were done each weekday. Results: Of 101 participants, 61 (59% women) met the inclusion criteria. Estimation formulas could be rounded to the following: TBD = 0.2 x weight (kg) or 0.4 x TDD; ICR = 300 divided by TDD; and CF = 1500 divided by TDD. In particular the relationship between all 3 dosing factors could be represented as 100 divided by TBD = ICR = CF divided by 4.5. Conclusions: These results suggest that current formulas give a higher estimate for TBD and a lower estimate for the bolus dose. (Endocr Pract. 2010;16:428-432)
引用
收藏
页码:428 / 432
页数:5
相关论文
共 50 条
  • [41] The Study to Estimate the Long-Acting Effect of Insulin Degludec in Type 1 Diabetes: Using a Continuous Glucose Monitoring and Insulin Pump
    Hashimura, Kayako
    Kawamura, Tomoyuki
    Hotta, Yuko
    Hatano, Megumi
    Kashihara, Yoneo
    Hashimoto, Tomomi
    Hirose, Masakazu
    Higashide, Takashi
    Aono, Mayumi
    Aono, Shigeo
    Shintaku, Haruo
    DIABETES, 2015, 64 : A265 - A265
  • [42] INSULIN PUMP-RT ADVISOR: A DECISION SUPPORT SOFTWARE FOR DIABETIC PATIENTS TREATED BY INSULIN PUMP AND USING CONTINUOUS GLUCOSE MONITORING
    Guilhem, I.
    Lefebvre, M-A
    Assayag, Y.
    Lam, E.
    Poirier, J-Y
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A105 - A106
  • [43] Hypoglycemia evaluation using continuous glucose monitoring system in type 1 diabetic patients treated by continuous subcutaneous insulin infusion by pump
    Sirault, Bruno
    Crenier, Laurent
    ACTA CLINICA BELGICA, 2016, 71 : 38 - 38
  • [44] Continuous glucose monitoring and all-cause mortality in insulin-using population with diabetes and cognitive impairment
    Kotecha, Pareeta
    Chen, Weihan
    Donahoo, William T.
    Jaffee, Michael
    Bian, Jiang
    Guo, Jingchuan
    DIABETES OBESITY & METABOLISM, 2024, 26 (10): : 4795 - 4798
  • [45] Optimising use of rate-of-change trend arrows for insulin dosing decisions using the FreeStyle Libre flash glucose monitoring system
    Ajjan, Ramzi A.
    Cummings, Michael H.
    Jennings, Peter
    Leelarathna, Lalantha
    Rayman, Gerry
    Wilmot, Emma G.
    DIABETES & VASCULAR DISEASE RESEARCH, 2019, 16 (01): : 3 - 12
  • [46] Meal size estimation using continuous glucose monitoring: towards a hybrid closed-loop artificial pancreas
    Bequette, B. W.
    Lee, H.
    Caswell, K.
    Dassau, E.
    Doyle, F. J., III
    Buckingham, B. A.
    DIABETOLOGIA, 2008, 51 : S433 - S433
  • [47] Continuous Glucose Monitoring (CGM) reduces glucose variability and improves glycaemic control in patients using Multiple Daily Injections (MDI) or insulin pumps
    Rodbard, D.
    Garg, S.
    Jovanovic, L.
    DIABETOLOGIA, 2009, 52 : S364 - S365
  • [48] CUFF-LESS BLOOD PRESSURE ESTIMATION SYSTEM ENABLES CONTINUOUS MONITORING DURING SLEEP. HOW DO WE BELIEVE THAT ESTIMATION VALUES?
    Eda, H.
    Yamazaki, M.
    SLEEP MEDICINE, 2017, 40 : E87 - E87
  • [49] Examining the Relationship Between Pre- and Postprandial Glucose Levels and Insulin Bolus Timing Using Bluetooth-Enabled Insulin Pen Cap Technology and Continuous Glucose Monitoring
    Toschi, Elena
    Slyne, Christine
    Greenberg, Jordan M.
    Greaves, Tori
    Atakov-Castillo, Astrid
    Carl, Sam
    Dufour, Alyssa B.
    Munshi, Medha
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (01) : 19 - 24
  • [50] Continuous Glucose Monitoring in Non-Insulin-Using Individuals with Type 2 Diabetes: Acceptability, Feasibility, and Teaching Opportunities
    Allen, Nancy A.
    Fain, James A.
    Braun, Barry
    Chipkin, Stuart R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (03) : 151 - 158