Modified Glassy Carbon Electrode with Silver Nanoparticles/Polyaniline/Reduced Graphene Oxide Nanocomposite for the Simultaneous Determination of Biocompounds in Biological Fluids

被引:4
|
作者
Ghanbari, Kh [1 ]
Moloudi, M. [1 ]
Bonyadi, S. [1 ]
机构
[1] Alzahra Univ, Fac Phys & Chem, Dept Chem, Tehran 1993891167, Iran
关键词
Ag Nanoparticles; Graphene Oxide; Ascorbic Acid; Dopamine; Uric Acid; ASCORBIC-ACID; URIC-ACID; ELECTROCHEMICAL DETERMINATION; DOPAMINE; SENSOR; FABRICATION;
D O I
10.33961/jecst.2019.00080
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The silver nanoparticles/polyaniline/reduced graphene oxide nanocomposite modified glassy carbon electrode (Ag/PANI/RGO/GCE) was prepared by the electrochemical method. The Ag/PANI/RGO nanocomposite was characterized by transmission electron microscopy (TEM), field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, X-ray diffraction (XRD), and electrochemical impedance spectroscopy (ESI). Two electrochemical techniques namely differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were used to the electrochemical behaviors investigation of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The Ag/PANI/RGO/GCE exhibited remarkable electrocatalytic activity towards the oxidation reaction of AA, DA, and UA in Britton-Robinson (BR) solution (pH=4.0). Under the optimal conditions, the determinations of AA, DA, and UA were accomplished using DPV. AA-DA and DA-UA peak potential separations were 130 and 180 mV, respectively. For simultaneous detection, the linear response ranges were in the two concentration ranges of 0.05-0.8 mM and 2.0-16.0 mM with detection limit 0.412 mu M (S/N = 3) for AA, 0.7-90.0 mu M and 90.0-1000.0 mu M with detection limit 0.023 mu M (S/N = 3) for DA, and 0.8-70.0 mu M and 70.0-1000.0 mu M with detection limit 0.050 mu M (S/N = 3) for UA. This modified electrode showed good sensitivity, selectivity, and stability with applied to determine AA, DA, and UA in human urine and drug.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 50 条
  • [21] Simultaneous electrochemical determination of dopamine and paracetamol on multiwalled carbon nanotubes/graphene oxide nanocomposite-modified glassy carbon electrode
    Cheemalapati, Srikanth
    Palanisamy, Selvakumar
    Mani, Veerappan
    Chen, Shen-Ming
    TALANTA, 2013, 117 : 297 - 304
  • [22] Copper Nanoparticles/Poly Acrylic Acid/Reduced Graphene Oxide Nanocomposite Modified Glassy Carbon Electrode for Determination of 4-Nitrophenol in Water
    Zhang Cui-Zhong
    Zhang Zhen-Fa
    Lian Huan
    Liang Cai-Yun
    Li Kai
    Peng Jin-Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 28 - 34
  • [23] Voltammetric Determination of Gallic Acid with a Glassy Carbon Electrode modified with Reduced Graphene Oxide
    Lisnund, Sireerat
    Blay, Vincent
    Chansaenpak, Kantapat
    Pinyou, Piyanut
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (08): : 7214 - 7227
  • [24] Electrochemical deposition of gold nanoparticles on reduced graphene oxide modified glassy carbon electrode for simultaneous determination of levodopa, uric acid and folic acid
    Benvidi, Ali
    Dehghani-Firouzabadi, Afsaneh
    Mazloum-Ardakani, Mohammad
    Mirjalili, Bi-Bi Fatemeh
    Zare, Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 : 22 - 29
  • [25] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [26] Modifying a Glassy Carbon Electrode with Reduced Graphene Oxide for the Determination of Levofloxacin with a Glassy
    Ghanbari, Mohammad Hossein
    Rahimi-Nasrabadi, Mehdi
    Sobati, Hossein
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (02): : 189 - 200
  • [27] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Marzieh Jafari
    Javad Tashkhourian
    Ghodratollah Absalan
    Journal of the Iranian Chemical Society, 2017, 14 : 1253 - 1262
  • [28] Electrochemical sensing of D-penicillamine on modified glassy carbon electrode by using a nanocomposite of gold nanoparticles and reduced graphene oxide
    Jafari, Marzieh
    Tashkhourian, Javad
    Absalan, Ghodratollah
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1253 - 1262
  • [29] Electroanalytical Determination of Ziram by Differential Pulse Voltammetry with Reduced Graphene Oxide/Gold Nanoparticles Modified Glassy Carbon Electrode
    Aslan, Nazife
    Ocak, Sema Bilge
    Gokmen, Ugur
    ACTA CHIMICA SLOVENICA, 2022, 69 (03) : 638 - 646
  • [30] Simultaneous voltammetric determination of droxidopa, acetaminophen, and tyrosine on hematoxylin and graphene oxide/ZnO nanocomposite-modified glassy carbon electrode
    Beitollahi, Hadi
    Salimi, Hadiseh
    Ganjali, Mohammad Reza
    IONICS, 2018, 24 (05) : 1487 - 1495