Overhead lines fault location and arc voltage estimation numerical algorithm derived in time domain

被引:0
|
作者
Djuric, MB [1 ]
Terzija, VV [1 ]
Radojevic, ZM [1 ]
机构
[1] Univ Belgrade, Fac Elect Engn, YU-11001 Belgrade, Yugoslavia
来源
ELECTRICAL ENGINEERING | 1998年 / 81卷 / 01期
关键词
D O I
10.1007/BF01233056
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new fault location numerical algorithm based on terminal data and derived in time domain is presented. The fault location and its nature (arcing or arcless fault) are estimated using least error squares technique. The faulted phase voltage is modelled as a serial connection of fault resistance and are voltage. The new approach does not require the line zero sequence resistance as an input datum. In the paper some important features of are voltage are given. The algorithm is derived for the most frequent case of single-phase line to ground unsymmetrical fault. The results of algorithm testing by computer simulation and under laboratory conditions are given. The influences of remote infeed, fault resistance, higher order harmonics, network topology and other factors are investigated and presented.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [31] An Intelligent Fault Location Algorithm of High Voltage Lines Using Cascading Deep Network
    Yang, Lei
    Gu, Yuge
    Wu, Man
    Liu, Yanhong
    2021 7TH INTERNATIONAL CONFERENCE ON ROBOTICS AND ARTIFICIAL INTELLIGENCE, ICRAI 2021, 2021, : 99 - 105
  • [32] A numerical algorithm for fault location estimation considering long-transmission line
    Kim, Byeong-Man
    Chae, Myeong-Suk
    Kang, Yong-Cheol
    Transactions of the Korean Institute of Electrical Engineers, 2008, 57 (12): : 2139 - 2146
  • [33] New Parameter-Free Fault Location Algorithm for Transmission Lines in Phasor Domain
    Padmanabhan, S.
    Terzija, V.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [34] Accurate Fault Location Method Based on Time-Domain Information Estimation for Medium-Voltage Distribution Network
    Sun, Guanqun
    Chen, Rusi
    Han, Zheyu
    Liu, Haiguang
    Liu, Meiyuan
    Zhang, Ke
    Xu, Chaozheng
    Wang, Yikai
    ELECTRONICS, 2023, 12 (23)
  • [35] An Improved Phasor Domain Parameter-Free Fault Location Algorithm on Untransposed Lines
    Lu, Dian
    Liu, Yu
    Xie, Boqi
    Fan, Rui
    Sun, Liangyi
    2020 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2020,
  • [36] Single-Ended Fault Location Determination on High-Voltage Overhead Power Lines with the Account for the Reactive Component of Fault Impedance
    Kulikov, A.L.
    Kolobanov, P.A.
    Podshivalin, A.N.
    Zhafyarov, A.R.
    Power Technology and Engineering, 2024, 58 (02) : 367 - 376
  • [37] FAULT LOCATION ON OVERHEAD LINES WITH TAPPINGS HAVING VARIABLE PASSIVE PARAMETERS
    AIZENFEL.AI
    ELECTRICAL TECHNOLOGY, 1973, (02): : 170 - 170
  • [38] Fault Location Study of Overhead Line-Cable Lines with Branches
    Cao, Wensi
    Zhao, Lixing
    Li, Zhaohui
    Chen, Jianming
    Xu, Mingming
    Niu, Rongze
    PROCESSES, 2023, 11 (08)
  • [39] Increase of Accuracy of the Fault Location Methods for Overhead Electrical Power Lines
    Lebedev, Vladimir
    Filatova, Galina
    Timofeev, Alexander
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [40] A Fault Location and Realization Method for Overhead High Voltage Power Transmission
    Jiang Zhen Bao
    Zhong Tingjian
    Ye Mao
    CEIS 2011, 2011, 15