In vitro fracture resistance of posterior metal-ceramic and all-ceramic inlay-retained resin-bonded fixed partial dentures

被引:55
|
作者
Kiliçarslan, MA
Kedici, PS [1 ]
Kücükesmen, HC
Uludag, BC
机构
[1] Ankara Univ, Hekimligi Fak, Protetik Tedavisi Anabilim Dali, TR-06500 Ankara, Turkey
[2] Ankara Dent Hosp, Ankara, Turkey
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2004年 / 92卷 / 04期
关键词
D O I
10.1016/j.prosdent.2004.07.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. In lay-retained resin-bonded fixed partial dentures (RBFPDs) are conservative prosthetic restorations; however, their resistance to fracture is not clear. Purpose. The purpose of this study, was to compare fracture loads of posterior complete coverage metal-ceramic restorations with all-ceramic inlay-retained RBFPDs. Material and methods. Thirty-two posterior ceramic RBFPD restorations were divided into 4 groups (n=8): (1) Complete metal-ceramic fixed partial dentures (MC-FPDs) fabricated of Ni-Cr-based alloy (Wirolloy) and veneered with a ceramic (IPS d.SIGN) as the control group; (2) inlay-retained metal-ceramic (MC RBFPDs) with the same materials as the control; (3) inlay-retained lithium disilicate (LD) glass-ceramic (IPS Empress 2) RBFPDs; and (4) inlay-retained zirconia-based (Z) ceramic (Cercon) RBFPDs. Control specimens were prepared to receive conventional complete MC-FPDs designed to include a 1.3-mm-circumferential, 90-degree flat shoulder with rounded angles. Inlay-retained RBFPD specimens were prepared with 2-mm occlusal reduction but without bevels at the occlusal or gingival margins. Specimens were loaded and fracture loads (N) measured at fracture with a universal testing machine at a crosshead speed of 1.0 mm/min and 250 kgf load cell. Data were analyzed with 1-way ANOVA and Duncan test (alpha=.001). Results. Fracture loads (mean +/- SD) were greatest for control specimens (1318.43 +/- 211.00 N) and Z-RBFPD (1247.70 +/- 262.51 N) specimens as compared to MC-RBFPD or LD-RBFPD (P<.001). MC-RFFPD exhibited the next highest fracture loads (958.01 +/- 194.29 N), and LD-RBFPD exhibited the significantly lowest values (303.23 +/- 92.54 N) of the materials tested (P<.001). Conclusion. Inlay-retained zirconia-based ceramic RBFPDs demonstrated the greatest fracture resistance among all inlay-retained restorations tested.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [21] Fracture Resistance of Three Ceramic Inlay-Retained Fixed Partial Denture Designs. An In Vitro Comparative Study
    Mohsen, Cherif A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (07): : 531 - 535
  • [22] Metal-free inlay-retained fixed partial dentures
    Edelhoff, D
    Spiekermann, H
    Yildirim, M
    QUINTESSENCE INTERNATIONAL, 2001, 32 (04): : 269 - 281
  • [23] Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
    Oh, WS
    Anusavice, KJ
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (05): : 536 - 542
  • [24] Clinical Survival of Anterior Metal-Ceramic and All-Ceramic Cantilever Resin-Bonded Fixed Dental Prostheses over a Period of 60 Months
    Saker, Samah
    El-Fallal, Abeer
    Abo-Madina, Manal
    Ghazy, Mohamed
    Oezcan, Mutlu
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2014, 27 (05) : 422 - 424
  • [25] Clinical Performance of Posterior Inlay-Retained and Wing-Retained Monolithic Zirconia Resin-Bonded Fixed Partial Dentures: Stage One Results of a Randomized Controlled Trial
    Boemicke, Wolfgang
    Rathmann, Friederike
    Pilz, Maximilian
    Bermejo, Justo Lorenzo
    Waldecker, Moritz
    Ohlmann, Brigitte
    Rammelsberg, Peter
    Zenthoefer, Andreas
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (05): : 384 - 393
  • [26] Influence of design and mode of loading on the fracture strength of all-ceramic resin-bonded fixed partial dentures: An in vitro study in a dual-axis chewing simulator
    Koutayas, SO
    Kern, M
    Ferraresso, F
    Stub, JR
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 83 (05): : 540 - 547
  • [27] In vitro comparison of the load-bearing capacity of ceramic and metal-ceramic resin-bonded fixed dental prostheses in the posterior region
    Boemicke, Wolfgang
    Waldecker, Moritz
    Krisam, Johannes
    Rammelsberg, Peter
    Rues, Stefan
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01): : 89 - 96
  • [28] A comparative mechanical and bone remodelling study of all-ceramic posterior inlay and onlay fixed partial dentures
    Field, Clarice
    Li, Qing
    Li, Wei
    Thompson, Mark
    Swain, Michael
    JOURNAL OF DENTISTRY, 2012, 40 (01) : 48 - 56
  • [29] Clinical outcome of metal- and all-ceramic resin-bonded fixed dental prostheses
    Zitzmann, Nicola U.
    von Buren, Anja
    Glenz, Fabienne
    Rohr, Nadja
    Joda, Tim
    Zaugg, Lucia K.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (02) : 243 - 248
  • [30] Validation of in-vitro tests of zirconia-ceramic inlay-retained fixed partial dentures: A finite element analysis
    Waldecker, M.
    Rues, S.
    Rammelsberg, P.
    Boemicke, W.
    DENTAL MATERIALS, 2019, 35 (03) : E53 - E62