Immediate Echocardiographic Surveillance After Transcatheter Closure of a Patent Ductus Arteriosus: A Feasible Method to Assess Residual Shunt

被引:1
|
作者
Liang, Chi-Di [1 ,2 ]
Ko, Sheung-Fat [2 ,3 ]
Huang, Chien-Fu [1 ,2 ]
Chien, Shao-Ju [1 ,2 ]
Lin, Ying-Jui [1 ,2 ]
Lin, I-Chun [1 ,2 ]
Tiao, Mao-Meng [1 ,2 ]
机构
[1] Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Pediat, Kaohsiung 833, Taiwan
[2] Chang Gung Univ, Coll Med, Kaohsiung 833, Taiwan
[3] Chang Gung Mem Hosp, Kaohsiung Med Ctr, Dept Radiol, Kaohsiung 833, Taiwan
来源
PEDIATRICS AND NEONATOLOGY | 2010年 / 51卷 / 01期
关键词
coil; echocardiography; hemolysis; patent ductus arteriosus; residual shunt; TERM FOLLOW-UP; COIL OCCLUSION; GIANTURCO COILS; HEMOLYSIS; MM; EXPERIENCE;
D O I
10.1016/S1875-9572(10)60010-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: To evaluate the feasibility of echocardiography after transcatheter closure of patent ductus arteriosus (PDA) with coils. Methods: Between April 1998 and December 2006, 131 patients had transcatheter coil occlusion of their PDA using Gianturco coils. We hypothesized that post-procedural hemolysis would not occur if a residual shunt <1 mm or if no continuous waveform was detected by echocardiography. Immediately after coil implantation, patients without and with a residual shunt as detected by echocardiography were designated to groups A and B, respectively. The clinical presentations, laboratory data and outcomes were compared between the two groups. Results: There were 101 patients in group A and 30 patients in group B. Patients in group B had larger ductal diameter (2.8 +/- 0.9 mm vs. 1.6 +/- 0.8 mm; p<0.001), larger Qp/Qs (1.9 +/- 0.9 vs. 1.3 +/- 0.4; p=0.001), higher frequency of more than one coil used (14/30 vs. 11/101; p<0.001), and female predominance (22/30 vs. 53/101; p=0.043) compared with group A. Trivial. residual shunt was noted in 6 patients in group A and 20 patients in group B on the day after embolization. All shunts spontaneously closed within 6 months in patients of group A, while five patients in group B had a persistent shunt at the 1-year follow-up and thereafter. Although the patients in group B had higher residual shunt rate than group A during follow-up (p<0.001), none of these patients suffered from hemolysis. Conclusion: Echocardiography is a feasible toot to assess residual shunt after PDA closure. If a residual shunt <1 mm or if no continuous waveform is detected by echocardiography, the risk of developing hemolysis is low.
引用
收藏
页码:52 / 56
页数:5
相关论文
共 50 条
  • [21] Transcatheter Echocardiographic-Guided Closure of Patent Ductus Arteriosus in Extremely Premature Newborns
    Vincent, Robert N.
    Bauser-Heaton, Holly
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (23) : 2438 - 2439
  • [22] Transcatheter patent ductus arteriosus closure with echocardiographic guidance: can radiation exposure be reduced?
    Tanidir, Ibrahim Cansaran
    Guzeltas, Alper
    Ergul, Yakup
    Ozturk, Erkut
    Ozyilmaz, Isa
    Odemis, Ender
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2014, 42 (07): : 643 - 650
  • [23] Transcatheter occlusion of residual patent ductus arteriosus after surgical ligation
    Podnar, T
    Masura, J
    PEDIATRIC CARDIOLOGY, 1999, 20 (02) : 126 - 130
  • [24] Transcatheter Occlusion of Residual Patent Ductus Arteriosus After Surgical Ligation
    T. Podnar
    J. Mašura
    Pediatric Cardiology, 1999, 20 : 126 - 130
  • [25] Transcatheter closure of patent ductus arteriosus using coils
    Hijazi, ZM
    Geggel, RL
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (09): : 1279 - &
  • [26] TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PIGLETS
    LOCK, JE
    BASS, JL
    LUND, G
    RYSAVY, JA
    LUCAS, RV
    AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (06): : 826 - 829
  • [27] TRANSCATHETER CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS IN ADULTS
    VERIN, V
    PANDE, AK
    MEIER, B
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1992, 5 (03) : 209 - 217
  • [28] DuctOcclud® -: Implant for transcatheter closure of patent Ductus Arteriosus
    Moore, JW
    Boosfeld, C
    BIOMEDIZINISCHE TECHNIK, 1999, 44 (03): : 46 - 51
  • [29] Echocardiographic guidance for transcatheter patent ductus arteriosus closure in extremely low birth weight infants
    Johnson, Jason Nathaniel
    Sathanandam, Shyam
    Naik, Ronak
    Philip, Ranjit
    CONGENITAL HEART DISEASE, 2019, 14 (01) : 74 - 78
  • [30] Patent ductus arteriosus with persistent pulmonary artery hypertension after transcatheter closure
    Feng, Jianqi
    Kong, Xiangqing
    Sheng, Yanhui
    Yang, Rong
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2016, 12 : 1609 - 1613