Impact analysis of tap switch out of step for converter transformer

被引:0
|
作者
Zhang Hong-yue [1 ]
Zhang Zhen-hua [1 ]
Xiong Zhang-xue [1 ]
Yu Gao-wang [1 ]
机构
[1] XJ Grp Ltd, Xuchang 461000, Peoples R China
关键词
D O I
10.1088/1755-1315/69/1/012200
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
AC transformer load regulation is mainly used to adjust the load side voltage level, improve the quality of power supply, the voltage range is relatively narrow. In DC system, converter transformer is the core equipment of AC and DC power converter and inverter. converter transformer tap adjustment can maintain the normal operation of the converter in small angle range control, the absorption of reactive power, economic operation, valve less stress, valve damping circuit loss, AC / DC harmonic component is also smaller. In this way, the tap switch action is more frequent, and a large range of the tap switch adjustment is required. Converter transformer with a more load voltage regulation switch, the voltage regulation range of the switch is generally 20 similar to 30%, the adjustment of each file is 1%similar to 2%. Recently it is often found that the tap switch of Converter Transformers is out of step in Converter station. In this paper, it is analyzed in detail the impact of tap switch out of step for differential protection, overexcitation protection and zero sequence over current protection. Analysis results show that: the tap switch out of step has no effect on the differential protection and the overexcitation protection including the tap switch. But the tap switch out of step has effect on zero sequence overcurrent protection of out of step star-angle converter transformer. The zero sequence overcurrent protection will trip when the tap switch out of step is greater than 3 for out of step star-angle converter transformer.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] An isolated single-switch high step-up DC/DC converter with three-winding transformer for solar photovoltaic applications
    Maheswari, L.
    Sivakumaran, N.
    ELECTRICAL ENGINEERING, 2020, 102 (03) : 1383 - 1392
  • [42] Analysis of limit cycle stability in a tap-changing transformer
    Donde, V
    Hiskens, IA
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL V, PROCEEDINGS, 2002, : 693 - 696
  • [43] Design and analysis of pulse transformer in forward converter
    Nanjing Li Gong Daxue Xuebao, 1 (90-92):
  • [44] Proposal of a new high step-up hybrid switch converter with reduced switch voltage stress
    Saleem, M., 1600, International Journal of Computer Science Issues (IJCSI) (09): : 5 - 1
  • [45] Impact analysis of a multi-variables modulation on the transformer of the dual-active-bridge converter
    Fraytag, Jeferson
    Kirsten, Andre Luis
    Heldwein, Marcelo Lobo
    IET POWER ELECTRONICS, 2020, 13 (05) : 1041 - 1050
  • [46] Electric Field Analysis for Valve-side Lead-out Insulation Structure of UHVDC Converter Transformer
    Zheng J.
    Kong J.
    Liang H.
    Zheng Y.
    Feng Y.
    Wen K.
    Gaodianya Jishu/High Voltage Engineering, 2022, 48 (09): : 3526 - 3532
  • [47] Improvement of Step-Voltage Regulating Transformer Efficiency Through Tap Changer Control Modification
    Clark, Scott W.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [48] Analysis and Design of a Single-Switch High Step-Up Coupled-Inductor Boost Converter
    Zheng, Yifei
    Smedley, Keyue Ma
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (01) : 535 - 545
  • [49] A Dual-transformer Active-Clamp Forward Converter using a single switch
    Lakshmi, G. R. P.
    2017 INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY INFORMATION AND COMMUNICATION (ICCPEIC), 2017, : 644 - 647
  • [50] Analysis and implementation of a novel single-switch high step-up DC-DC converter
    Hsieh, Y. -P.
    Chen, J. -F.
    Liang, T. -J.
    Yang, L. -S.
    IET POWER ELECTRONICS, 2012, 5 (01) : 11 - 21