The discharge development and arc modes in vacuum at a long gap distance in vacuum interrupters

被引:6
|
作者
Cheng Shaoyong [1 ]
Xiu Shixin [1 ]
Wang Jimei [1 ]
Shen Zhengchao [1 ]
机构
[1] Xian Jiaotong Univ, Xian 710049, Peoples R China
关键词
vacuum arc; arc mode; gap distance;
D O I
10.1088/1009-0630/9/1/09
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The influence of an arc current on the discharge development and the arc modes of a single coil type axial magnetic field (AMF) electrode were investigated by a high-speed charge couple device (CCD) video camera in a long gap distance of 40 mm. The distribution of the axial magnetic field of the single coil type AMF electrode was computed. By computational results, the single coil type AMF electrode could generate higher axial magnetic flux density than the slot type AMF electrode. It was found that the single coil type AMF electrode could perform better than the slot type AMF electrode with the same designing parameters. And the development of the arc modes experienced diffuse mode, constricted but unstable mode, and constricted and stable mode with the amplitude of the arc current increasing. The correlation between the vacuum arc and the noise components of arc voltage was investigated too. The interruption capability could be known in a practical commercial vacuum interrupter by the test results in a demountable vacuum interrupter (DVC) with a electrode diameter of 50 mm and a gap distance of 40 mm. The test results could provide reference to design the high voltage vacuum interrupter adopting the single coil type AMF electrode.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [11] DISCHARGE MODES AT THE ANODE OF A VACUUM-ARC
    MILLER, HC
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1983, 11 (03) : 122 - 127
  • [12] POST ARC CURRENT OF VACUUM INTERRUPTERS
    YANABU, S
    HOMMA, M
    KANEKO, E
    TAMAGAWA, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (01): : 166 - 172
  • [13] POST ARC CURRENT IN VACUUM INTERRUPTERS
    YANABU, S
    SATOH, Y
    HONMA, M
    TAMAGAWA, T
    KANEKO, E
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (04) : 209 - 214
  • [14] Vacuum Testing of a Sample of Long Service Vacuum Interrupters
    Falkingham, L. T.
    Reeves, R.
    Gill, C. H.
    Mistry, S.
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 93 - 96
  • [15] Long-term vacuum integrity of vacuum interrupters
    Taylor, E. D.
    Lawall, A.
    Gentsch, D.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 433 - 436
  • [16] Influence of the pulsed AMF arc control on the vacuum arc and post arc characteristic in vacuum interrupters
    Ge, Guowei
    Cheng, Xian
    Liao, Minfu
    Xue, Qinkuan
    Zou, Jiyan
    VACUUM, 2018, 147 : 65 - 71
  • [17] Influence of the Pulsed AMF Arc Control on the Vacuum Arc and Post Arc Characteristic in Vacuum Interrupters
    Ge, Guowei
    Cheng, Xian
    Liao, Minfu
    Xue, Qinkuan
    Zou, Jiyan
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 157 - 160
  • [18] Current constriction of high-current vacuum arc in vacuum interrupters
    Wang, Lijun
    Jia, Shenli
    Zhang, Ling
    Yang, Dingge
    Shi, Zongqian
    Gentils, Francois
    Jusselin, Benoit
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (06)
  • [19] Arc-voltage analysis for vacuum state estimation in vacuum interrupters
    Anghelita, P
    Kerkenaar, RWP
    Merck, WFH
    ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 443 - 446
  • [20] New Arc Control Design for Vacuum Interrupters
    Kantas, Said
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2013, 41 (07) : 1709 - 1715