Catheter ablation of left-sided accessory pathways in small children

被引:6
|
作者
Fogelman, Rami [1 ]
Birk, Einat [1 ]
Dagan, Tamir [1 ]
Fogelman, Michal [1 ]
Einbinder, Tom [1 ]
Bruckheimer, Elchanan [1 ]
Swissa, Moshe [2 ]
机构
[1] Tel Aviv Univ, Sackler Sch Med, Cardiol Inst, Schneider Childrens Med Ctr Israel, Petah Tiqwa, Israel
[2] Hebrew Univ Jerusalem, Kaplan Med Ctr, Jerusalem, Israel
关键词
left-sided accessory pathway; radiofrequency catheter ablation; three-dimensional system; trans-septal puncture; Wolf-Parkinson-White syndrome; PEDIATRIC POPULATION; RADIOFREQUENCY; TACHYARRHYTHMIAS; TACHYCARDIA; ADOLESCENTS; ARRHYTHMIAS; SAFETY;
D O I
10.1002/joa3.12219
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Accessory pathways (APs) are a common reason for supraventricular tachycardia in small children. Trans-septal puncture (TSP) approach is commonly used for the ablation of left-sided APs, however it may be challenging in small children. The aim of this study was to assess the efficacy and safety of trans-septal approach radiofrequency (RF) ablation of left-sided APs in children weighing up to 30 kg. Methods Of the 658 children who underwent catheter ablation of APs since 06/2002, 86 children had left-sided AP and weighed less than 30 kg. TSP approach guided with TEE and fluoroscopy was used for left atrium access. Results The mean age, height, and body weight were 7.6 +/- 1.9 years, 122.4 +/- 9.3 cm and 24.0 +/- 4.2 kg, respectively. Forty-three children (50%) were male, 46 of 86 (53%) had manifest AP, 17 of 86 (20%) weighed less than 20 kg and in 24 of 86 children (28%) a three-dimensional system (3DS) was used to reduce fluoroscopy time. The acute success rate was 98.8% (85/86), with a recurrence rate of 2.4% (2/85) in a mean follow-up of 66.2 +/- 42.7 (9.1-184.2) months. The mean procedure time and fluoroscopy time were significantly lower for the 3DS group compared to the standard fluoroscopy group 131 +/- 41 (55-262) and 2.4 +/- 1.5 (1-6) minutes vs 164 +/- 51 (62-249) and 27 +/- 13 (8-77) minutes, P P < 0.0001, respectively. There were no ablation-related complications. Conclusions RF ablation of left-sided APs using TSP approach in small children had an excellent efficacy and safety profile. The use of 3DS significantly reduces the procedure and fluoroscopy time.
引用
收藏
页码:742 / 747
页数:6
相关论文
共 50 条
  • [21] Successful Ablation of a Unique Left-sided Accessory Pathway
    Irie, Tadanobu
    Kaneko, Yoshiaki
    Nakajima, Tadashi
    Kurabayashi, Masahiko
    INTERNAL MEDICINE, 2014, 53 (11) : 1231 - 1232
  • [22] Ablation of Supraventricular Tachycardias From Concealed Left-Sided Nodoventricular and Nodofascicular Accessory Pathways
    Cardona-Guarache, Ricardo
    Han, Frederick T.
    Nguyen, Duy T.
    Chicos, Alexandru B.
    Badhwar, Nitish
    Knight, Bradley P.
    Johnson, Colleen J.
    Heaven, David
    Scheinman, Melvin M.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (05):
  • [23] 3-DIMENSIONAL ELECTROGRAM MAPPING IMPROVES ABLATION OF LEFT-SIDED ACCESSORY PATHWAYS
    FISHER, WG
    SWARTZ, JF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (12): : 2344 - +
  • [24] Radiofrequency ablation of atrial insertion of left-sided accessory pathways guided by the ''W sign''
    Manolis, AS
    Wang, PJ
    Estes, NAM
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1995, 6 (12) : 1068 - 1076
  • [25] RADIOFREQUENCY ABLATION OF LEFT-SIDED ACCESSORY ATRIOVENTRICULAR PATHWAYS IN PATIENTS WITH UNUSUAL CORONARY SINUS
    CHIANG, CE
    CHEN, SA
    TSANG, WP
    HSIA, CP
    WANG, DC
    CHIOU, CW
    YANG, CR
    WANG, SP
    CHIANG, BN
    CHANG, MS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01): : 62 - 69
  • [26] CATHETER ABLATION OF ACCESSORY PATHWAYS IN CHILDREN
    HAISSAGUERRE, M
    PUEL, V
    BEKHEIT, S
    FISHER, B
    DARTIGUES, JF
    EGLOFF, P
    LEMETAYER, P
    CLEMENTY, J
    WARIN, JF
    EUROPEAN HEART JOURNAL, 1994, 15 (02) : 200 - 205
  • [27] Use of three-dimensional catheter guidance and trans-esophageal echocardiography to eliminate fluoroscopy in catheter ablation of left-sided accessory pathways
    Clark, John
    Bockoven, J. R.
    Lane, John
    Patel, C. R.
    Smith, Grace
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (03): : 283 - 289
  • [28] A NEW PIGTAIL TYPE CATHETER FOR RETROGRADE ATRIAL LEFT-SIDED ACCESSORY PATHWAY MAPPING AND ABLATION
    AVITALL, B
    HARE, J
    KRUM, D
    SILVERSTEIN, E
    BLANCK, Z
    CIRCULATION, 1993, 88 (04) : 63 - 63
  • [29] Incidence of intervention-related cardiac valve lesions after radiofrequency catheter ablation of left-sided accessory atrioventricular pathways
    Neuzner, J
    Faude, I
    Pitschner, HF
    Schlepper, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (12): : 1002 - 1008
  • [30] VALUE OF LOCAL ELECTROGRAM CHARACTERISTICS PREDICTING SUCCESSFUL CATHETER ABLATION OF LEFT-SIDED VERSUS RIGHT-SIDED ACCESSORY ATRIOVENTRICULAR PATHWAYS BY RADIOFREQUENCY CURRENT
    LIN, JL
    SCHIE, JT
    TSENG, CD
    CHEN, WJ
    CHENG, TF
    TSOU, SS
    CHEN, JJ
    TSENG, YZ
    LIEN, WP
    CARDIOLOGY, 1995, 86 (02) : 135 - 142