Application of CFD to closed-wet cooling towers

被引:54
|
作者
Gan, G [1 ]
Riffat, SB [1 ]
Shao, L [1 ]
Doherty, P [1 ]
机构
[1] Univ Nottingham, Sch Built Environm, Inst Bldg Technol, Nottingham NG7 2RD, England
关键词
cooling tower; heat exchanger; multi-phase flow; pressure loss; computational fluid dynamics;
D O I
10.1016/S1359-4311(00)00048-X
中图分类号
O414.1 [热力学];
学科分类号
摘要
Computational fluid dynamics (CFD) is applied to predicting the performance of closed-wet cooling towers (CWCTs) for chilled ceilings according to the cooling capacity and pressure loss. The prediction involves the two-phase flow of gas and water droplets. The predicted thermal performance is compared with experimental measurement for a large industrial CWCT and a small prototype cooling tower. CFD is then applied to the design of a new cooling tower for field testing. The accuracy of CFD modelling of the pressure loss for fluid flow over the heat exchanger is assessed for a range of flow velocities applied in CWCTs. The predicted pressure loss for single-phase flow of air over the heat exchanger is in good agreement with the empirical equation for tube bundles. CFD can be used to assess the effect of flow interference on the fluid distribution and pressure loss of single- and multi-phase flow over the heat exchanger. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:79 / 92
页数:14
相关论文
共 50 条
  • [41] An Analytical Approach to Wet Cooling Towers Based on Functional Analysis
    Qianjian, Guo
    Qi, Xiaoni
    Wei, Zheng
    Sun, Peng
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2019, 2019
  • [42] COMPARISON OF DIFFERENT COMBINATIONS OF WET AND DRY COOLING-TOWERS
    CLEVE, HHV
    MECHANICAL ENGINEERING, 1976, 98 (02) : 86 - 86
  • [43] THERMODYNAMIC MODELS OF DRY-WET COOLING-TOWERS
    CROLEY, TE
    PATEL, VC
    CHENG, MS
    JOURNAL OF THE POWER DIVISION-ASCE, 1976, 102 (01): : 1 - 19
  • [44] CONSUMPTION CRITERIA AND ENERGY LABELING OF WET COOLING TOWERS IN IRAN
    Sajadi, B.
    Sayyadi, P.
    Saidi, M. H.
    ASME POWER CONFERENCE 2009, 2009, : 153 - 157
  • [45] Effect of forced ventilation on the thermal performance of wet cooling towers
    Zhang, Deying
    Wang, Nini
    Li, Jinpeng
    Li, Jinheng
    He, Suoying
    Gao, Ming
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 35
  • [46] Crosswinds effect on the performance of natural draft wet cooling towers
    Al-Waked, Rafat
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) : 218 - 224
  • [47] DETERMINATION OF INDUSTRIAL DIMENSIONS AND EMISSION OF WET COOLING-TOWERS
    BAER, E
    DITTRICH, H
    ERNST, G
    ROLLER, W
    WURZ, W
    BRENNSTOFF-WARME-KRAFT, 1980, 32 (02): : 69 - 70
  • [49] Numerical Modelling of Natural Draft Wet-Cooling Towers
    Adam Klimanek
    Archives of Computational Methods in Engineering, 2013, 20 : 61 - 109
  • [50] Energy and exergy analysis of counter flow wet cooling towers
    Saravanan, M.
    Saravanan, R.
    Renganarayanan, S.
    THERMAL SCIENCE, 2008, 12 (02): : 69 - 78