Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS

被引:21
|
作者
Palomino-Bautista, Carlos [1 ]
Sanchez-Jean, Ruben [1 ]
Carmona-Gonzalez, David [1 ]
Pinero, David P. [2 ,3 ]
Molina-Martin, Ainhoa [2 ]
机构
[1] Univ Hosp Quironsalud, Dept Ophthalmol, Madrid, Spain
[2] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente del Raspeig S-N, Alicante 03690, Spain
[3] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante, Spain
关键词
INTRAOCULAR LENSES; FOCUS; ACUITIES;
D O I
10.1038/s41598-021-91654-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p<0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p<0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r=0.73, p<0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.
引用
收藏
页数:8
相关论文
共 28 条
  • [21] Visual outcomes and patient satisfaction after implantation of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and multifocal profiles
    Ribeiro, Filomena J.
    Ferreira, Tiago B.
    Silva, Diana
    Matos, Ana Claudia
    Gaspar, Sylvia
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : 1448 - 1453
  • [22] Comparative analysis of a presbyopia-correcting intraocular lens that combines extended depth-of-focus and bifocal profiles with a standard monofocal intraocular lens
    Da Eun Shin
    Hun Lee
    Kyungmin Koh
    BMC Ophthalmology, 22
  • [23] Real-world outcomes of a novel presbyopia-correcting intraocular lens with a non-diffractive design implanted in patients with altered ocular surface (EVOLVE study)
    Lawless, Michael
    Chang, Lily Yu-Li
    Perez-Vives, Caridad
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 948 - 949
  • [24] Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
    Novacek, Ladislav Viktor
    Nemcova, Marie
    Tyx, Katerina
    Lahodova, Kristyna
    Rejmont, Leos
    Rozsival, Pavel
    Studeny, Pavel
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [25] Real-world visual performance and patient satisfaction of a novel presbyopia-correcting intraocular lens, with a non-diffractive design, implanted in patients with posterior segment concerns (EVOLVE study)
    McCartney, Paul J.
    Chang, Lily Y. -L.
    Perez-Vives, Caridad
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 946 - 947
  • [26] Optical quality and depth-of-field of eyes implanted with spherical and aspheric intraocular lenses
    Marcos, S
    Barbero, S
    Jiménez-Alfaro, I
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (03) : 223 - 235
  • [27] Visual Outcomes and Optical Quality of Accommodative, Multifocal, Extended Depth-of-Focus, and Monofocal Intraocular Lenses in Presbyopia-Correcting Cataract Surgery A Systematic Review and Bayesian Network Meta-analysis
    Cho, Jeong-Yeon
    Won, Yeo Kyoung
    Park, Jongyeop
    Nam, Jin Hyun
    Hong, Ji-Yoon
    Min, Serim
    Kim, Nahyun
    Chung, Tae-Young
    Lee, Eui-Kyung
    Kwon, Sun-Hong
    Lim, Dong Hui
    JAMA OPHTHALMOLOGY, 2022, 140 (11) : 1045 - 1053
  • [28] Geometry of Modern Presbyopia-Correcting Intraocular Lenses and Changes in Haptic-Capsular Bag Behavior According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (12) : 3059 - 3077