Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS

被引:21
|
作者
Palomino-Bautista, Carlos [1 ]
Sanchez-Jean, Ruben [1 ]
Carmona-Gonzalez, David [1 ]
Pinero, David P. [2 ,3 ]
Molina-Martin, Ainhoa [2 ]
机构
[1] Univ Hosp Quironsalud, Dept Ophthalmol, Madrid, Spain
[2] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente del Raspeig S-N, Alicante 03690, Spain
[3] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante, Spain
关键词
INTRAOCULAR LENSES; FOCUS; ACUITIES;
D O I
10.1038/s41598-021-91654-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To evaluate depth of field (DOF) provided by different presbyopia-correcting intraocular lens (IOL) designs, comparing the results obtained using different criteria for defining the defocus tolerance. A total of 150 eyes undergoing cataract surgery were enrolled and divided into 6 groups depending on the IOL implanted: AT.LISA Tri (Carl Zeiss Meditec), FineVision (PhysIOL), PanOptix (Alcon Laboratories), Tecnis Symfony (Johnson & Johnson Vision), Miniwell (SIFI MedTech) and Tecnis Synergy (Johnson & Johnson Vision). Subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance of 0.1 logMAR. Aberrometry was also measured and the visual strehl optical transference function (VSOTF) with percentage of degradation of 90%, 80% and 60% was used to quantify objectively the DOF. Tecnis Symfony, Tecnis Synergy and Panoptix IOL groups showed better subjective and objective DOF compared to the rest of IOL groups, being these differences statistically significant differences (p<0.001). Comparison between subjective and objective DOF showed that subjective measures were higher for all IOLs, being also these differences statistically significant for all groups (p<0.001). A moderate significant correlation was found between absolute subjective criteria and VSOTF60% (r=0.73, p<0.05). Objective and subjective measures of DOF are not comparable due to differences in methodologies and criterions to define the level of degradation tolerance. Nevertheless, both objective and subjective measures showed a trend to a greater DOF for Tecnis Symfony and Tecnis Synergy IOLs compared to most of trifocal diffractive designs, with the exception of PanOptix.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] Depth of field measures in pseudophakic eyes implanted with different type of presbyopia-correcting IOLS
    Carlos Palomino-Bautista
    Rubén Sánchez-Jean
    David Carmona-Gonzalez
    David P. Piñero
    Ainhoa Molina-Martín
    Scientific Reports, 11
  • [2] Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery
    Camps, Vicente J.
    Miret, Juan J.
    Garcia, Celia
    Tolosa, Angel
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (04) : 222 - +
  • [3] Monovision LASIK Versus Presbyopia-Correcting IOLs: Comparison of Clinical and Patient-Reported Outcomes
    Schallhorn, Steven C.
    Teenan, David
    Venter, Jan A.
    Schallhorn, Julie M.
    Hettinger, Keith A.
    Hannan, Stephen J.
    Pelouskova, Martina
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) : 749 - +
  • [4] Multicenter clinical investigation of visual function after bilateral implantation of two presbyopia-correcting trifocal IOLs
    Ghyczy, E.
    Lapid-Gortzak, R.
    Martinez, A.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 34 - 34
  • [5] Innovative trifocal (quadrifocal) presbyopia-correcting IOLs: 1-year outcomes from an international multicenter study
    Kohnen, Thomas
    Marchini, Giorgio
    Alfonso, Jose F.
    Bala, Chandra
    Cochener, Beatrice
    Martinez, Aldo
    Carreno, Edgardo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (08): : 1142 - 1148
  • [6] Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results
    Lapid-Gortzak, Ruth
    Bhatt, Uday
    Sanchez, Juan Gonzalo
    Guarro, Merce
    Hida, Wilson Takashi
    Bala, Chandra
    Nose, Ricardo Menon
    Rodriguez Alvira, Francisco Jose
    Martinez, Aldo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (11): : 1534 - 1542
  • [7] Presbyopia-correcting performance and subjective outcomes of a trifocal intraocular lens in eyes with different axial lengths: A prospective cohort study
    Sun, Tong
    Liu, Yiyun
    Zhao, Xiaorui
    Gao, Yufei
    Yang, Tingting
    Lan, Qianqian
    Tang, Chuhao
    Qi, Hong
    FRONTIERS IN MEDICINE, 2022, 9
  • [8] Clinical Outcomes with a Novel Extended Depth of Focus Presbyopia-Correcting Intraocular Lens: Pilot Study
    Iradier, Maria T.
    Cruz, Veronica
    Gentile, Naty
    Cedano, Priscila
    Pinero, David P.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 1215 - 1221
  • [9] In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs
    Montagud-Martinez, Diego
    Ferrando, Vicente
    Martinez-Espert, Anabel
    Garcia-Delpech, Salvador
    Monsoriu, Juan A.
    Furlan, Walter D.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (05)
  • [10] Self-rated quality of vision and optical phenomena intensity of diffractive presbyopia-correcting IOLs: EDoF, trifocal vs panfocal
    Boehm, Myriam
    Hemkeppler, Eva
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (08): : 877 - 886