A large-scale fire test of an immersed tunnel under the protection of fire resistive coating

被引:27
|
作者
Duan, Jintao [1 ]
Dong, Yuli [1 ]
Xiao, Jianzhuang [2 ]
Zhang, Dashan [1 ]
Zheng, Wei [1 ]
Zhang, Shengyao [1 ]
机构
[1] Huaqiao Univ, Coll Civil Engn, Xiamen, Peoples R China
[2] Tongji Univ, Coll Civil Engn, Shanghai 200092, Peoples R China
基金
中国国家自然科学基金;
关键词
Fire test; Immersed tunnel; Fire resistive coating; Concrete cracks; Fire resistance; REINFORCED-CONCRETE; RESIDUAL STRENGTH; PERFORMANCE; BEHAVIOR; MODEL;
D O I
10.1016/j.tust.2021.103844
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The damage caused by fire can seriously affect the durability and safety of an immersed tunnel, including the reduction of structural bearing capacity and the spalling and cracking of concrete. Fire resistive coating is one of the usual measures to protect the tunnel from fire. In this study, a large-scale (1/5) immersed tunnel was built to carry out a fire test of the immersed tunnel under the protection of fire resistive coating. During the fire test, the heating phase lasted for 365 min, and the cooling phase lasted for 120 min. In the heating phase, the average temperature of the fire in the tunnel reached 1113.7 degrees C. Under the protection of fire resistive coating, the maximum concrete temperature was 412.4 degrees C, which was 701.3 degrees C lower than the average temperature of the fire. During the fire test, the deformations of the tunnel were very small, and the maximum deformation was 6.8 mm. But the concrete cracked seriously on the outside of the tunnel under fire, and the maximum crack width reached 1.86 mm. The concrete cracking not only occurred in the right tube which was exposed to fire, but also occurred in the mid gallery and left tube which were not exposed to fire. According to the temperature of vapor and water in the cracks on the ceiling recorded by the infrared thermography, it was inferred that the depth of cracks in the ceiling had reached 18 cm at 245 min. The acoustic emission signals show that the concrete cracks were mainly formed in the early stage of the fire test (the first 100 min), which is consistent with the macro phenomena of cracks development. The results of the fire test indicate that under the protection of fire resistive coating, the concrete temperatures were high and there was no concrete spalling, and the deformations of the tunnel were small, but the concrete cracking of the tunnel was very serious. Because the immersed tunnel is buried in the seabed, concrete cracks have a great impact on the durability and safety of the immersed tunnel. In the fire resistance design of the immersed tunnel, more attention should be paid to the concrete cracking of the immersed tunnel.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] ANALYSIS OF LARGE-SCALE FIRE TEST DATA
    PEACOCK, RD
    BABRAUSKAS, V
    FIRE SAFETY JOURNAL, 1991, 17 (05) : 387 - 414
  • [2] Bench scale fire resistive test
    Lin, Ching-Yuan
    Cheng, Shao-Tsai
    Journal of Fire Sciences, 17 (02): : 148 - 168
  • [3] Bench scale fire resistive test
    Lin, CY
    Cheng, ST
    JOURNAL OF FIRE SCIENCES, 1999, 17 (02) : 148 - 168
  • [4] FIRE PROTECTION FOR ELECTRICAL EQUIPMENT OF LARGE-SCALE BUILDINGS
    ACHILLES, E
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1975, 27 (01): : 15 - 16
  • [5] Pulsations during large-scale fire tests in the Runehamar tunnel
    Lönnermark, A
    Persson, B
    Ingason, H
    FIRE SAFETY JOURNAL, 2006, 41 (05) : 377 - 389
  • [6] Fire Spread and Flame Length in Large-Scale Tunnel Fires
    Anders Lönnermark
    Haukur Ingason
    Fire Technology, 2006, 42 : 283 - 302
  • [7] Fire spread and flame length in large-scale tunnel fires
    Lonnermark, Anders
    Ingason, Haukur
    FIRE TECHNOLOGY, 2006, 42 (04) : 283 - 302
  • [8] A review of test Methods, issues and challenges of Large-Scale fire testing of concrete tunnel linings
    Lee, Wei Ming
    Fragomeni, Sam
    Monckton, Hugh
    Guerrieri, Maurice
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 392
  • [9] Influences of silicone emulsion on fire protection of waterborne intumescent fire-resistive coating
    Dong, Ying
    Wang, Guojian
    Yang, Jiayun
    JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, 2014, 11 (02) : 231 - 237
  • [10] Influences of silicone emulsion on fire protection of waterborne intumescent fire-resistive coating
    Ying Dong
    Guojian Wang
    Jiayun Yang
    Journal of Coatings Technology and Research, 2014, 11 : 231 - 237