Improved overcurrent protection using symmetrical components

被引:19
|
作者
Lotfi-fard, Saeed [1 ]
Faiz, Jawad
Iravani, Reza
机构
[1] Univ Tehran, Dept Elect & Comp Engn, Tehran 14395, Iran
[2] Univ Toronto, Dept Elect Engn, Toronto, ON M5S 3G4, Canada
关键词
fault; overcurrent relay; switching; symmetrical components;
D O I
10.1109/TPWRD.2007.893591
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transient currents are quite common in power systems. They can be presented for both faults and switching events. In the case of switching events, such transients should not cause an overcurrent relay operation; therefore a dependable and secure relay response becomes a critical matter. Meanwhile, proper techniques must be used to prevent undesirable relay operations due to transient current and harmonics of current in the power system. This paper uses the concept of symmetrical components to discriminate fault from nonfault events. For this purpose, a criterion function is proposed using the above-mentioned components. The advantage of the proposed algorithm is shown by simulation of some typical transient currents due to transformer energizing and induction motor starting using EMTDC/PSCAD software.
引用
收藏
页码:843 / 850
页数:8
相关论文
共 50 条
  • [1] Improved protection systems using symmetrical components
    Kojovic, LA
    Witte, JF
    [J]. 2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 47 - 52
  • [2] Analysis of Unsymmetrical fault using Symmetrical component for Improvement of Overcurrent Protection Scheme
    Mrugsarita
    Borkar, D.
    Kawita
    Thakur, D.
    [J]. 2013 INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATION AND INFORMATICS, 2013,
  • [3] Improved Overcurrent Protection of Capacitor Banks Using Mathematical Morphology
    Buggaveeti, Sravan K.
    Brahma, Sukumar M.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (03) : 1972 - 1979
  • [4] DIGITAL LINE DIFFERENTIAL PROTECTION USING SYMMETRICAL COMPONENTS
    LOBOS, T
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1991, 22 (02) : 85 - 89
  • [5] Extreme overcurrent analysis for the protection of automotive circuit components
    Batchelor, AR
    Smith, JR
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2001, 148 (02) : 55 - 62
  • [6] A new IDMT overcurrent protection scheme with improved selectivity
    Chan, D.T.W.
    Lu, C.Z.
    [J]. Ciencia y Engenharia/ Science and Engineering Journal, 2001, 10 (01): : 30 - 37
  • [7] The Use of Symmetrical Components in Electrical Protection
    Ciontea, Catalin Iosif
    [J]. 2019 72ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2019,
  • [8] Protection Coordination Method Using Symmetrical Components in Loop Distribution System
    Lee, Jung-Hun
    Kim, Woo-Hyun
    Lee, Hak-Ju
    Kim, Jun-Oh
    Chae, Woo-Kyu
    [J]. ENERGIES, 2021, 14 (16)
  • [9] Adaptive and Optimal Overcurrent Protection of Wind Farms with Improved Reliability
    Uddin, M. Nasir
    Rezaei, Nima
    Emmanuel, Osaji
    [J]. 2021 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2021,
  • [10] Adaptive and Optimal Overcurrent Protection of Wind Farms With Improved Reliability
    Uddin, Mohammad
    Rezaei, Nima
    Olufemi, Osaji Emmanuel
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (03) : 3342 - 3352